TAC:66421
From kanterella
Jump to navigation
Jump to search
Request for: Open | |
Initiation
Questions Answers | |
| From | |
MONTHYEARML17303A6501987-10-0808 October 1987
[table view]Corrected Ltr Providing Info Util Received from C-E & Ksb Pump Co Re Ksb Reactor Coolant Pump Shaft Cracks Experienced in European Power Facilities.Subj Shaft Cracks &/Or Failure at European Facilities Is Not Safety Concern for Plant ML17300B0621987-10-0808 October 1987 Discusses Reactor Coolant Pump Shaft Cracks Experience in European Power Facilities.Analysis & Evaluation of Activities Useful to Accident Analysis ML17303A6401987-10-21021 October 1987 Provides Preliminary Results of Reactor Coolant Pump Shaft Insp for Potential Fatigue Cracking,Including Comparison of Results W/European Insp Results,Action Plan for Facility & Justification for Operation of Units ML17303A6511987-10-29029 October 1987 Forwards Corrected 871008 & 21 Ltrs Re Reactor Coolant Pump Shafts.W/O Encls ML17303B0671988-04-20020 April 1988 Forwards Info Re Preliminary Investigation of Reactor Coolant Pump Shafts,Per 880418 Telcon.Shafts Visually & Wet Fluorescent Magnetic Particle Examined for Evidence of Cracks 1987-10-29 | |