MONTHYEARML20206E6241987-03-23023 March 1987
[table view]Discusses 870313 Reactor Trip from 92% Power.Trip Due to Personnel Error When Main Feedwater Stop Valve FW-601 Inadvertently Closed.Sequence of Events Listed.Restart Test Program Completed.Detailed Info & Collected Data Encl 05000346/LER-1987-006, :on 870313,reactor Trip Occurred.Caused by Closure of Main Feedwater Stop Valve for Steam Generator 2 After Const Worker Bumped Local Control Switch.Cover Installed Over Switch for Valve1987-04-10010 April 1987
ML20214S0981987-06-0101 June 1987 Informs That Sys Review & Test Program Completed.Sys Important for Safe Operation Functionally Adequate.Addl Info Will Be Utilized in Assessing or Confirming Plant Response to Transient Conditions ML20235X2671987-07-21021 July 1987 Ack Receipt of Describing 870313 Unplanned Trip & Focusing on How Trip Fulfilled Objectives of 870314 Planned Trip as Final Action of Sys Review & Test Program. Objective 3 Not Met & Objective 2 Not Exactly Met ML20237C8151987-12-14014 December 1987 Forwards Sys Review & Test Program Review of Trip Test Objectives Following 870821 Reactor Trip.Data Re Evaluation of Plant Response for Loss of One Main Feedwater Pump from High Power Will Be Collected in Future Event 1987-04-10 | |