TAC:59964
From kanterella
Jump to navigation
Jump to search
Request for: Approved, Closed | |
| |
From | |
MONTHYEARB11972, Forwards Results of Evaluation of Ref Temp for Pressurized Thermal Shock from Time of Submittal to Expiration Date of Ol.Values Do Not Exceed Screening Criteria.Paragraphs (b)(3)-(6) of 10CFR50.61 Inapplicable to Facilities1986-01-23023 January 1986
[table view]Forwards Results of Evaluation of Ref Temp for Pressurized Thermal Shock from Time of Submittal to Expiration Date of Ol.Values Do Not Exceed Screening Criteria.Paragraphs (b)(3)-(6) of 10CFR50.61 Inapplicable to Facilities ML20215M6171986-10-20020 October 1986 Forwards Request for Addl Info Re Matl Properties for Fracture Toughness Requirements for Protection Against Pressurized Thermal Shock Events.Justification for Copper & Nickel Contents & Initial RTNDT Values Requested A06174, Forwards Response to 861020 Request for Addl Info Re Review of 860123 Submittal Concerning Matl Properties for Fracture Toughness Requirements for Protection Against PTS1986-12-19019 December 1986 Forwards Response to 861020 Request for Addl Info Re Review of 860123 Submittal Concerning Matl Properties for Fracture Toughness Requirements for Protection Against PTS ML20209H0341987-04-24024 April 1987 Forwards Request for Addl Info in Order to Continue Review of 861222 Application Re Expiration of Facility OL & 860123 Submittal Re Pressurized Thermal Shock ML20235H7571987-07-0606 July 1987 Submits Response to NRC 870424 Request for Addl Info Re PTS & Info Requested During 870701 Telcon Re Satisfaction of 10CFR50.61 Requirements Concerning Pts,Including Neutron Fluence on 860123 A06530, Responds to NRC Request for Addl Info Re Fluence Calculation Performed to Assess Compliance w/10CFR50.61 Re Pts.Predicted Controlling Rt(Pts) Value Based on Worst Case Assumption of 40% Uncertainty in Estimated Fluence Listed1987-07-31031 July 1987 Responds to NRC Request for Addl Info Re Fluence Calculation Performed to Assess Compliance w/10CFR50.61 Re Pts.Predicted Controlling Rt(Pts) Value Based on Worst Case Assumption of 40% Uncertainty in Estimated Fluence Listed ML20237G7281987-08-24024 August 1987 Safety Evaluation Re Fast Neutron Fluence for Fracture Toughness Requirements for Protection Against PTS Events. Plant Satisfies Fracture Toughness Requirements for Protection Against PTS ML20237G7171987-08-24024 August 1987 Forwards Safety Evaluation Re Util 860123,870706 & 31 Submittals Concerning Pts.Estimated Value of Fast Neutron Fluence to Pressure Vessel to Have Conservative Error Margins & Acceptable 1987-04-24 |
Retrieved from "https://kanterella.com/w/index.php?title=TAC:59964&oldid=3423380"