TAC:54446
From kanterella
Jump to navigation
Jump to search
Request for: Open | |
Initiation
Questions Answers Results
Other: 05000266/LER-1984-002, :on 840228,licensee Notified by Swri That One Indication in Each Outlet Nozzle Weld Exceeded ASME Code Allowable Size.Caused by Entrapped Foreign Matl in Weld. Requirements of ASME Section XI Satisfied, ML20087E176, ML20087L506, ML20087N435, ML20087N438, ML20087N443 | |
| From | |
MONTHYEARML20087E1761984-03-12012 March 1984
[table view]Submits Evaluation Procedure for Reactor Vessel Outlet nozzle-to-shell Weld Indication,Per IWB-3122.4 of ASME Section Xi.Flaws Acceptable.Continued Svc Warranted Based on Evaluation Results ML20087L5061984-03-23023 March 1984 Discusses Reactor Vessel Outlet nozzle-to-shell Weld Flaw Indication Evaluation.Requirements of ASME Section XI Satisfied & Reactor Vessel Confirmed for Continued Operation ML20087N4431984-03-27027 March 1984 Reactor Vessel Outlet Nozzle-to-Shell Weld Flaw Indication Fracture Mechanics Evaluation for Point Beach Nuclear Plant, Unit 1 05000266/LER-1984-002, :on 840228,licensee Notified by Swri That One Indication in Each Outlet Nozzle Weld Exceeded ASME Code Allowable Size.Caused by Entrapped Foreign Matl in Weld. Requirements of ASME Section XI Satisfied1984-03-28028 March 1984
ML20087N4381984-03-30030 March 1984 Sizing of Ultrasonically Detected Indications in Point Beach,Unit 1 Reactor Pressure Vessel Outlet Nozzles ML20087N4351984-03-30030 March 1984 Forwards Sizing of Ultrasonically Detected Indications in Point Beach,Unit 1 Reactor Pressure Vessel Outlet Nozzles, & Reactor Vessel Outlet Nozzle-to-Shell Weld Flaw Indication Fracture Mechanics Evaluation for .. 1984-03-27 | |
Retrieved from "https://kanterella.com/w/index.php?title=TAC:54446&oldid=3495271"