TAC:54356
From kanterella
Jump to navigation
Jump to search
Request for: Open | |
Initiation
Questions Answers | |
| From | |
MONTHYEARML16340C7931982-07-23023 July 1982
[table view]Requests That Board Notification of Control Rod Drive Guide Tube Support Pin Failures Should Be Brought to Attention of ASLB & Aslab.Sufficient Safety Significance Exists to Warrant Notification ML20087K2161984-03-0505 March 1984 Westinghouse Safety Evaluation,Cracked Control Rod Guide Tube Support Pins ML20087K2101984-03-19019 March 1984 Forwards Safety Evaluation of Damaged Control Rod Guide Tube Support Pins.Ut Indictions on shank-to-collar Not Safety Concern ML20087Q0551984-04-0606 April 1984 Submits Results of 840403 Check Valve Leak Check to Identify Presence of Debris or Split Pin Parts in Pressure Isolation Valves Between RCS & Safety Injection Sys.Results of Cold Rod Test Satisfactory ML20092N8591984-06-27027 June 1984 Submits Results of Hot Control Rod Drop Testing Conducted Prior to Startup of Cycle 12.Control Rod at Location H-6 Dropped on 840406.Caused by Magnetite Crud Binding Drive Mechanism 1984-03-05 | |