TAC:51732
From kanterella
Jump to navigation
Jump to search
Request for: Open | |
Initiation
Questions Answers | |
| From | |
MONTHYEAR05000278/LER-1976-074-03, /03L:on 761123,core Spray B Full Flow Test Return Valve Failed to Close During Surveillance.Caused by Torque Switch Setting to Low.Torque Switch Setting Increased & Valve Satisfactorily Stroked1976-12-27027 December 1976
[table view]/03L:on 761123,core Spray B Full Flow Test Return Valve Failed to Close During Surveillance.Caused by Torque Switch Setting to Low.Torque Switch Setting Increased & Valve Satisfactorily Stroked 1976-12-27 | |
Retrieved from "https://kanterella.com/w/index.php?title=TAC:51732&oldid=3498325"