- 05000302/LER-1977-104, Forwards Rev 1 to LER 77-104 Re Four RCS Flow Instruments Exceeding Calibr Tolerances.Util Revising Commitment to Agree W/Tech Specs to Calibr Transmitters Every 18 Months (← links)
- 3F0185-16, Suppls Response to NRC Re Deviation Noted in Insp Rept 50-302/84-26.Corrective Actions:Calibr Procedures SP-112 & SP-113 Revised in May to Add Computer Points R-713 & P-714,respectively,to Ensure Calibr (← links)
- 3F1195-25, Submits Discussion in Response to Concerns Re Proposed TS Change Request to Extend Most Refueling Interval Surveillances to 24 Months.Revised Copies of Instrument Drift Studies Included in Original Submittal Attached Also (← links)
- 05000302/LER-1982-011-03, /03L-0:on 820224,during Performance of SP-112,RC Flow,Channel a Was Found Out of Calibr.Caused by Linear Voltage Differential Transformer Shorting Out.Transformer Replaced & Instrument Calibr (← links)
- 05000302/LER-1981-070-03, /03L-0:on 811013,during Refueling Surveillance, Source Range Neutron Flux Monitoring Requirements Not Met on 811031,14 & 27.Caused by Instrument Drift & Grounded Cable. Instruments Recalibr & Cable Replaced (← links)
- 05000302/LER-1981-066-03, /03L-0:on 811010,various Reactor Protection Instruments Found Out of Tolerance.Caused by Bellows Failure,Instrument Drift & Loose Test Point Output Terminal. Bellows Replaced,Terminal Tightened & Instruments Recalibr (← links)
- 05000302/LER-1979-049-03, /03L-0 on 790509:count-rate Amplifier & Rate of Change Amplifier for Nuclear Source Range Instrument NI-1 Were Inoperable.Caused by Amplifiers Being Out of Tolerance Due to Instrument Drift.Amplifiers Recalibr (← links)
- 05000302/LER-1979-050-03, /03L-0 on 790510:count-rate Amplifier & Rate of Change Amplifier for Nuclear Source Range Instrument NI-2 Found Inoperable.Caused by Amplifiers Being Out of Tolerance Due to Instrument Drift.Amplifiers Recalbr & Returned to (← links)
- 05000302/LER-1979-086-03, /03L-0:on 790916,channel D Reactor Bldg High Pressure Bistable Tripped.Caused by Buildup of Dust on Shaft of Reactor Bldg Switch BS-62-PS.Switch Was Disassembled, Cleaned,Reassembled & Returned to Svc (← links)