Pages that link to "NRC Form 316A"
Jump to navigation
Jump to search
The following pages link to NRC Form 316A:
Displayed 21 items.
- ML20137H003 (← links)
- 05000382/LER-1998-001-01, :on 980214,TSs 3.0.3 Condition Occurred Due to Inoperable Charging Pumps.Replaced Failed SX-1 Relay (← links)
- 05000334/LER-1999-011, :on 990909,inadequate Axial Flux Difference Monitor Alarm Surveillance Was Noted.Caused by Lack of Info in Operations Surveillance Test Procedures 1OST-5A.1 & 2OST-5A.1.Revised Procedures.With (← links)
- 05000333/LER-1997-005, :on 970525,manual Reactor Scram Occurred Due to Failure of Number 3 Main Tcv.Caused by Damaged Valve Spring Can Coupling.Replaced Valve Spring Can Coupling Bolt of Four TCVs & Four CIVs & Completed Review (← links)
- 05000336/LER-1997-014-01, :on 970415,insufficient RBCCW Flow to HPSI Was Noted.Cause Unknown.Rbccw Sys Supplies Pump Seal Cooler W/ Cw,Providing Heat Removal to Ultimate Heat Sink Via Sws (← links)
- 05000423/LER-1997-045, :on 970616,identified Discrepancy Between FSAR & TS Definitions of Reactor Trip Sys Response Time.Caused by Mgt Expectations & Guidance Re Literal Compliance W/Ts Neither Clear Nor Adequately Communicated.Testing Changed (← links)
- 05000366/LER-1999-007, :on 990628,automatic Reactor Shutdown Occurred. Caused by Personnel Error & Inadequate Corrective Action. Involved Personnel Were Disciplined & Calibr of Level Instrument Has Been Changed (← links)
- 05000366/LER-1999-006, :on 990615,loss of Condenser Vacuum Leads to Manual Reactor Scram & ESF Actuation.Caused by Loss of Vacuum in Main Condenser.Operating Order Issued.With (← links)
- 05000245/LER-1997-006-01, :on 970131,failure to Exert Best Efforts to Restore Radwaste Effluent Line Radiation Monitor to Operable Status Occurred.Caused by Failure to Provide Clear Management Expectations.Management Will Be Provided (← links)
- 05000266/LER-1997-016, :on 970325,SG Level Logic Was Not Tested IAW Ts.Caused by Nonconservative Interpretation of Tss.Ts Amends Proposed to Provide Consistency Between Test Requirements & LCO Associated W/Sg Tests (← links)
- 05000245/LER-1997-020-01, :on 970227,discovered Downscale Annunciator for Unit 1 Liquid Radwaste Effluent Monitor Not Adequately Verified,Per Ts.Caused by Personnel Error.Surveillance Procedures Revised (← links)
- 05000266/LER-1997-012, :on 970304,diesel-drive Fire Pump Day Tank Not Sampled IAW TSs.Non-conservative Interpretation of TS Led to Failure.Day Tank T-30 Sample Was Drawn & Analyzed W/Satisfactory Results (← links)
- 05000245/LER-1995-008, :on 950411,potential Inoperability Was Determined Re Feedwater Coolant Injection Sys Upon Failure of S2 DC Power.Caused by Error That Occurred During Original Plant Design.Physical Plant Mods Have Been Completed (← links)
- 05000423/LER-1996-028, :on 960916,potential Overcooling of Charging Pump Lube Oil Sys Occurred Due to Failure of air-operated Temperature Control Valves.Temporary Mod to Limit Failure Position of Three Way Cce Temp Control Valve,Installed (← links)
- 05000498/LER-1992-021, :on 921215,identified That Main Steam Line Isolation Actuation & Response Time Test Did Not Satisfy Requirements.Caused by Personnel Error.Procedures Revised (← links)
- 05000266/LER-1996-001, :on 960405,inadvertent ESF Actuation in Train B Due to DC Sys Ground Occurred.Caused by Inadequate Ground Search Technique.Site Engineering Personnel Will Be Involved in Ground Detection Needed on DC Sys (← links)
- 05000458/LER-1995-010-02, :on 951130,reactor Thermal Power Limit Exceeded Due to Failure to Consider Required Heat Balance Inputs.No Recommended Corrective Actions Since All New Plant Designs Will Be Implemented as Mods (← links)
- 05000325/LER-1995-015, :on 950713,automatic Reactor Shutdown Occurred Due to electro-hydraulic Control Pressure Regulator Malfunction.Replaced Four Electronic Circuit Boards Comprising a EHC Pressure Regulator (← links)
- 05000389/LER-1987-007, :on 871125,reactor Tripped on Loss of Load Due to Turbine Trip.Caused by Personnel Error.Permanent Magnet Generator & Exciter Bearing Replaced & Exciter Bearing Thermocouple Removed (← links)
- 05000265/LER-2006-001, Re Two Mian Steam Safety Valves and Two Main Steam Safety/Relief Valves Outside of the Technical Specification Allowed Tolerance (← links)
- 05000334/LER-2006-001, Re Main Steam Safety Valve Relief Tests Exceeded Technical Specification Required Setpoint Tolerance (← links)