- 05000346/LER-1982-067-03, /03L-0:on 821217,while Performing Surveillance Test ST 5032.02,detector Signal of Fuel Handling Area Exhaust Radiation Monitor RE8447 Was Lost Whenever Detector Moved.Caused by Failed Internal Connector (← links)
- 05000346/LER-1982-059-03, /03L-0:on 821108,containment post-accident Radiation Monitor,Channel 2 Read Low.On 821116 & 22 Equipment Fail Alarm Received.Caused by Failed High Voltage Power Supply Board.Board Replaced & Declared Operable (← links)
- 05000346/LER-1982-047-03, /03L-0:on 820913 & 15 Containment Radiation Trip Occurred.Caused by Component Failure of Output Radiation Monitor RE-2004 on Safety Features Actuation Sys Channel 1. Operational Amplifier & Output Transistor Replaced (← links)
- 05000346/LER-1982-058-03, /03L-0:on 821106,while Performing ST 5032.01, Setpoints for Containment post-accident Radiation Monitor Re 4597BA Found Drifted,Rendering Monitor Inoperable. Caused by Component Failure.Microprocessor Boards Replaced (← links)
- 05000346/LER-1982-055-03, /03L-0:on 821021,safety Features Actuation Sys Channel 4 Radiation Monitor RE-2007 Failed Low.Cause Unknown.Detectors Replaced (← links)
- 05000346/LER-1982-013-03, /03L-0:on 820302,radiation Element Re 2007 in Safety Features Actuation Sys Channel 4 Failed Low.Caused by Broken Wire in Cable Connector in Penetration Box P4LIGX. Connector Reterminated & Detector Replaced (← links)
- 05000346/LER-1982-005-03, /03L-0:on 820126,RE 2007,containment Area Radiation Control Monitor to Safety Features Actuation Sys Channel 4 Failed Low.Exact Cause Unknown.New Detector Placed in Svc.Failed Detector Returned to Vendor (← links)
- 05000346/LER-1982-002-03, /03L-0:on 820103,radiation Detector RE2007 on Safety Features Actuation Sys Channel 4 Failed Low.Low Radiation Bistable Tripped & Alarmed.Caused by Fabrication Error in Attaching Shortened Cable Wire (← links)
- 05000346/LER-1981-064, Revised LER 81-064/03X-3:on 811012 & 13,pump for Re 5028, post-accident Containment Radiation Monitor,Failed.Caused by Decreased Flow Due to Pump Vane Wear.Maint Step Added to Check & Set Flow Weekly.Redundant Sys Operable Duri (← links)
- 05000346/LER-1981-064-03, /03X-2:on 811012 & 13,pump for post-accident Containment Radiation Monitor Re 5029 Found Not Running. Caused by Component Failure Due to Pump Vane Wear.Pump Replaced & Maint Work Order Revised to Check Flaws Weekly (← links)
- 05000346/LER-1982-049-03, /03L-0:on 820920 & 22,Channels 2 & 3 on Containment post-accident Radiation Monitor Re 4597BA Were Reading High.Caused by Problem in Microprocessor Software. New Set of Software Installed & Faulty Actuator Replaced (← links)
- 05000346/LER-1980-068-03, /03L-0:on 800901,all Indicators for Meteorological Instrumentation Failed.Caused by Lightning Striking Tower, Resulting in High Voltage Spike in Wind Direction Sensor. Repairs to Tower Sensors and Comstar Computer Completed (← links)
- 05000346/LER-1979-125-03, /03L-0:on 791208,during Surveillance Testing,Decay Heat Cooler 1-1 Component Cooling Water Outlet Valve CC1467 Did Not Stroke from Control Room Switch.Caused by Mechanical Linkage in Valve That Had Vibrated Loose.Design Chan (← links)
- 05000346/LER-1979-101-03, /03L-0:on 791017,safety Features Actuation Sys Channel 2 Radiation Detector Re 2005 Spiked Tripping Channel 2 Containment Radiation Bistable.Caused by Component Failure of Detector.Failed Detector Replaced (← links)
- 05000346/LER-1979-089-03, /03L-0:on 790811,single Failure Analysis Sys Channel 2 Containment Radiation Detector Re 2005 Spiked & Tripped Bistable.Re 2005 Declared Inoperable.Caused by Vibration in Area of Detector (← links)
- 05000346/LER-1979-097-03, /03L-0:on 791004,steam & Feedwater Rupture Control Sys Channel Supply Failed,Resulting in Half Trip.Caused by Failure of Sorenson Power Supply Which Provides Volt in Channel 4.Power Supply Replaced (← links)
- 05000346/LER-1979-080-03, /03L-0 on 790716:safety Features Actuation Sys Containment Radiation Detector Re 2005 Spiked & Tripped Channel 2 Containment Radiation Bistable.Caused by Component Failure.Detector Will Be Relocated Outside Containment (← links)