- 05000254/LER-1995-001, :on 950102,RCIC Governor Valve Failed to Meet Expected Capabilities During Unit Startup Due to Valve Steam Corrosion.Rcic Governor Valve Disassembled,Inspected & Repaired W/More Compatible Matls (← links)
- 05000265/LER-1994-011-06, :on 941006,thirty Day Limited Condition of Operation Exceeded for 2B RHR Swp Due to Inadequate Work Planning & Scheduling.Evaluating Inventory of Major Rhrswp Parts (← links)
- 05000254/LER-1994-011-05, :on 940829,CRD L-11 Failed to Scram When Given Signal Due to Pipe Plug Inserted Into Solenoid Valve Due to Personnel Not Adhering to Procedure.Crd Inserted to Position 00 & Insps Conducted for Similar Obstructions (← links)
- 05000265/LER-1994-017-03, :on 941205,banked Position Withdrawal Sequence Rules Violated Since Oct of 1991 Due to Training,Procedure & Work Practice Deficiencies in Nuclear Engineering Group. Retrained,Evaluation of Rod Drop Analysis (← links)
- 05000254/LER-1994-008-07, :on 940820,unit 1 Reactor Was Manually Scrammed by Procedure to Achieve Shutdown Condition Required by Tss. Caused by Work Practices Associated W/Crimping Terminal Lug. Wire Terminal Lugs Were Replaced W/New Parts (← links)
- 05000265/LER-1994-008-02, :on 940417,inboard & Outboard RR Sample Isolation Valves A0 2-220-44 & 45 Failed to Close.Cause of Event & Corrective Actions Still Under Investigation.W/ (← links)
- 05000254/LER-1994-007-03, :on 940321,HPCI Restricting Orifice (RO) Found Clogged Approx 95% Closed.Cause of Clogged RO Unknown.Steam Line Drain ROs & Steam Traps on Unit 2 HPCI & RCIC Sys Disassembled & Inspected (← links)
- 05000254/LER-1993-021, :on 931201,discovered That Fis 1-1360-7 Was Found to Have Failed Full Scale Due to Equipment Malfunctions.Switch Was Replaced & Both Units Were Calibrated to Work within Pressure Range (← links)
- 05000254/LER-1994-001-04, :on 940102,inadvertent Insertion of Control Rod H-1 from Position 48 to 14 Occurred During Instrument Maint Surveillance.Cause Not Determined.Crd H-1 Inserted Into Position 00 & HCU Rebuilt (← links)
- 05000254/LER-1994-005-02, :on 940314,LLRT Feedwater Check Valve 1-220-58B Failed Leak Test W/Unquantified Leakage.Cause Unknown. Corrective Actions Underway But Have Nor Been Completed at This Time (← links)
- 05000254/LER-1994-004-04, :on 940228,results of Feedwater Flow Testing Found Flow Indications in Nonconservative Direction.Cause Not Determined.Management Issued Special Instructions.W/ (← links)
- 05000265/LER-1993-018-01, :on 930828,MOV Failed Due to Broken End Bell Tie Bolts.Porter/Peerless Class B,Dc MOV Motors Replaced & Failed Bolts Tested (← links)
- 05000254/LER-1993-020-02, :on 931111,shutdown Cooling Flow Partially Lost Due to Opening of Reactor Recirculation Discharge Valve MO-1-202-5B.Caused by Inappropriate Actions.Valves MO-1-202-5A & 5B Taken Out of Svc (← links)
- 05000265/LER-1993-018-02, :on 930828,discovered Broken Bolts on RCIC Valve 2-1301-61.Cause Undetermined.Replaced Class B DC MOV Motors of 25 Lbs W/Improved Motor (← links)