Displayed 50 items.
- ML19270G109 (redirect page) (← links)
- ML19270G110 (← links)
- 05000333/LER-1978-112, Forwards LER 78-112/03L-0 (← links)
- 05000333/LER-1978-105, Forwards LER 78-105/03L-0 (← links)
- 05000333/LER-1978-082, Forwards LER 78-082/03L-0 (← links)
- 05000333/LER-1978-075, Forwards LER 78-075/03L-1 (← links)
- 05000333/LER-1978-087-04, /04T-0 on 781018:Environ Radiological Monitoring Sample of Periphyton Samples Pci/Gm(Wet)Does Not Meet Subj Facil Tech Spec Append B,Paragraph 5.6.2.6 (← links)
- 05000333/LER-1978-112-03, /03L-0 on 781226:discovered That Surveillance Requirements Not Performed on Air Operated Isolation Valves. Procedures Revised & Testing Completed W/Satisfactory Results (← links)
- 05000333/LER-1978-105-03, /03L-0 on 781214:operations Surveillance Test F-ST-15A,torus Water Level Exceeded Tech Spec Requirements, Due to drywell-to-torus Differential Pressure Drop to 0 Psi Caused by Test (← links)
- 05000333/LER-1978-094-03, /03L-0 on 781122:during Shutdown & Surveillance Test,A Number of Battery Cells Were Found W/Specific Gravity &/Or Individual Cell Voltage Variations(High or Low) Greater than Allowed by Test Acceptance Criteria (← links)
- 05000333/LER-1978-094, Forwards LER 78-094/03L-0 (← links)
- 05000333/LER-1978-085-04, /04X-1 on 781006:3rd Quarter Release of Halogens & Particulates Greater than Tech Specs.Caused by Steam Leaks & Fuel Pin Clad Performance (← links)
- 05000333/LER-1978-085, Forwards LER 78-085/04X-1 (← links)
- 05000333/LER-1978-090, Forwards LER 78-090/03L-0 (← links)
- 05000333/LER-1978-089-03, /03L-0 on 781101:during Refueling & Maint Shutdown It Was Found That Surveillance Test Had Not Been Performed for Combustion Ionization Products Smoke Detectors Installed in Diesel Fire Pump Room on 780310,due to Oversight (← links)
- 05000333/LER-1978-088-04, /04L-0 on 781024:excess Solute Release from Makeup Water Treatment Waste Neutralizer Tanks to Circulating Water Discharge Tunnel Detected.Caused by Unsound Sampling & Method of Determining Concentrations & Dissolved Solids (← links)
- 05000333/LER-1978-088, Forwards LER 78-088/04L-0 (← links)
- 05000333/LER-1978-086-03, /03L-0;on 781016,during Refuel Shutdown,Two Elec Conduits Passing Through Safety Related Area Fire Barrier Found to Be Improperly Sealed in Violation of Tech Spec. Both Penetrations Immediately Sealed (← links)
- 05000333/LER-1978-086, Forwards LER 78-086/03L-0 (← links)
- 05000333/LER-1978-087, Forwards LER 78-087/04T-0 (← links)
- 05000333/LER-1978-056-03, /03L-1:on 780722,core Spray Sys Outboard Isolation Valve Would Not Close.Caused by Sheared Limitorque Shaft Key.Key Replaced (← links)
- 05000333/LER-1978-082-03, /03L-0:on 780920,during Refueling Shutdown, Pressure Suppression Pool Torus Level Increased to 0.8 Inches Above Tech Spec Limit.Caused by Leaking Past Seat of Safety Relief Valve (← links)
- 05000333/LER-1978-075-03, /03L-1:on 780902,during Surveillance Test F-ST-3D, Normally Closed Inboard Core Spray Injection Valve 14-MOV-12B Failed to Open Electrically,Causing Sys Inoperability.Caused by High Differential Pressure (← links)
- 05000333/LER-1978-079-04, /04L-0 on 780914:An Apparent Excessive Solute Release from Makeup Water Treatment Waste Neutralizer Tanks to Circulating Water Discharge Tunnel Was Detected While Performing Aug 78 24-hour Complete Sample Analysis (← links)
- 05000333/LER-1978-079, Forwards LER 78-079/04L-0 (← links)
- 05000333/LER-1978-081-03, /03L-0 on 780915:circuit Breaker for RHR Pump 10-P 10-P-3C Would Not Charge. Caused by Bending of Control Pwr Fuse Holder Causing Pump Circuit Breaker Not to Make Contact (← links)
- 05000333/LER-1978-081, Forwards LER 78-081/03L-0 (← links)
- 05000333/LER-1978-048, :Number Not Used (← links)
- 05000333/LER-1978-106-03, /03L-0 on 781220:noted Coupling Key for Containment Pressure Suppression Pool Nitrogen Purge Supply valve(27-AOV-115)was Disengaged.Cause Unknown (← links)
- 05000333/LER-1978-106, Forwards LER 78-106/03L-0 (← links)
- 05000333/LER-1978-107-03, /03L-0 on 781221:combustion Ionization Product (Smoke) Detectors for Relay Room Intentionally Disabled During Repair Work.Detectors Verified Operable Following Repair Work (← links)
- 05000333/LER-1978-107, Forwards LER 78-107/03L-0 (← links)
- 05000333/LER-1978-108-04, /04L-0 on 781217:apparent Excessive Solute Release from Makeup Water Treatment Waste Neutralizer Tanks to Circulating Water Discharge Tunnel.Cause Not Stated (← links)
- 05000333/LER-1978-108, Forwards LER 78-108/04L-0 (← links)
- 05000333/LER-1978-109-03, /03L-0 on 781224:the a Residual Heat Removal Loop Could Not Be Maintained Full of Water Because a Discharge Check Valve Was Not Closing Properly.Disassembly Revealed No Cause for Sticking (← links)
- 05000333/LER-1978-109, Forwards LER 78-109/03L-0 (← links)
- 05000333/LER-1978-103-03, /03L-0 on 781211:during Shutdown for Refueling & Maint Insp of snubbers,4 Snubbers Were Declared Inoperable. Caused by Loss of Hydraulic Fluid in Snubbers (← links)
- 05000333/LER-1978-103, Forwards LER 78-103/03L-0 (← links)
- 05000333/LER-1978-059-03, /03L-0 on 780805:primary Containment Pressure Suppression Pool Level Exceeded Tech Specs Limit by Two Inches.Caused by Operator Failure to Isolate RHR Sys from keep-full Subsys (← links)
- 05000333/LER-1978-059 (redirect page) (← links)
- 05000333/LER-1978-096-03, /03L-0 on 781206:reactor Coolant Sample Indicated a Chloride Ion Sample of 0.180 Ppm Due to Inadvertent Contamination of the Sample W/Matl Containing High Amounts of Chloride Ions (← links)
- 05000333/LER-1978-096, Forwards LER 78-096/03L-0 (← links)
- 05000333/LER-1978-093-03, /03L-0 on 781204:wiring Error Found on 10% Closure Position Switch for Inboard Main Steam Isolation Valve B(29-AOV-8OB).Caused by Crossed Wires (← links)
- 05000333/LER-1978-093, Forwards LER 78-093/03L-0 (← links)
- 05000333/LER-1978-091-03, /03L-0 on 781201:low Level Radiation Test of Containment Penetrations Was Conducted & Indicated Leakage Exceeded Value of La Specified in Tech Specs.Probable Cause: Isolation Valves Associated W/ Penetrations (← links)
- 05000333/LER-1978-091, Forwards LER 78-091/03L-0 (← links)
- 05000333/LER-1978-008-03, /03L-0 on 780210:during Normal Plant Operation, Smoke Emanated from Supply Breaker for 13MOV131 Reactor Core Overload.Caused by Electrical Overload.Damaged Parts Replaced (← links)
- 05000333/LER-1978-008, Forwards LER 78-008/03L-0 (← links)
- 05000333/LER-1978-095-03, /03L-0 on 781206:during Refueling Outage,Some Fire Barrier Electrical Penetration Sleeves Were Intentionally Opened to Install New Cable.A Fire Watch Was Present & Penetrations Were Resealed & Inspected (← links)
- 05000333/LER-1978-095, Forwards LER 78-095/03L-0 (← links)
- 05000333/LER-1978-098-03, /03L-0 on 781205:emergency Diesel Generator a Tripped When Being Paralleled to Bus.Caused by Misadjustment of Engine Governor After Extended Maintenance Period (← links)