The following pages link to 05000325/LER-1982-004, Forwards LER 82-004/03L-0:
Displayed 50 items.
- ML20041A706 (redirect page) (← links)
- 05000325/LER-1982-004-03, /03L-0:on 820111,1-CAC-AR-1259 post-accident Monitoring Control Room Recorder/Indicator Exhibited Unvarying Indication of Drywell Oxygen Concentration.Caused by Broken Drive Cord Due to Normal Wear.Cord Replaced (← links)
- 05000325/LER-1982-004, Forwards LER 82-004/03L-0 (← links)
- 05000324/LER-1982-007-03, /03L-0:on 820113,reactor Coolant Activity Exceeded Tech Spec Limits for 38-h & 5 Minutes.Caused by Increases in Coolant Fission Product Inventory Originating from Leaking Fuel Elements (← links)
- 05000324/LER-1982-007, Forwards LER 82-007/03L-0 (← links)
- 05000324/LER-1982-004-03, /03L-0:on 820111,measured Oxygen Concentration in Drywall Exceeded Tech Spec Limit.Caused by Frozen Condensate in CAC Sys Primary Containment Inerting Vaporizer Condensate Return Lines.Lines Thawed.Model D16-L6 Utilized (← links)
- 05000324/LER-1982-004, Forwards LER 82-004/03L-0 (← links)
- 05000325/LER-1982-004-03, /03L-0:on 820111,1-CAC-AR-1259 post-accident Monitoring Control Room Recorder/Indicator Exhibited Unvarying Indication of Drywell Oxygen Concentration.Caused by Broken Drive Cord Due to Normal Wear.Cord Replaced (← links)
- 05000325/LER-1982-004 (redirect page) (← links)
- 05000325/LER-1982-007-03, /03L-0:on 820115,during Operability Testing, Reactor Core Isolation Cooling Turbine Control Valve 1-E51-V9 Would Not Open or Close Fully,Preventing Proper Speed Control.Caused by Diode VR1 Shortening (← links)
- 05000325/LER-1982-007, Forwards LER 82-007/03L-0 (← links)
- 05000325/LER-1982-008, Forwards LER 82-008/03L-0 (← links)
- 05000325/LER-1982-005-03, /03L-0:on 820112,during Control Bldg Chlorine Detection Sys Calibr,Required Annunciations for Simulated High Chlorine Signal Did Not Actuate.Caused by Corrosion of Detector Armature.Detector Replaced (← links)
- 05000324/LER-1982-008, Forwards LER 82-008/03L-0 (← links)
- 05000325/LER-1982-003-01, /01T-0:on 820118,idle Reactor Recirculation Pump Allowed to Start W/Greater than 50% Operating Loop Flow. Caused by Failure to Revise Applicable Plant Procedures. Procedures Revised (← links)
- 05000325/LER-1982-003, Forwards LER 82-003/01T-0 (← links)
- 05000324/LER-1982-005, Forwards LER 82-005/01T-0 (← links)
- 05000325/LER-1982-002-03, /03L-0:on 820105,primary Temp Recorder, 1-CAC-TR-1258,model 551,was Printing Erratically.Cause of Event Not Determined.Recorder Cleaned & Lubricated (← links)
- 05000324/LER-1982-009-01, /01T-0:on 820111,svc Water Bldg South Side Sprinkler & Standpipe Sys Isolated While Maint Performed on Fire Support Sys.Caused by Failure of Drawings to Reflect Required Position of Sys Isolation Valves Properly (← links)
- 05000324/LER-1982-041, Forwards Updated LER 82-041/03L-2 (← links)
- 05000325/LER-1982-125-03, /03L-0:on 821222,during Reactor Scram Recovery, Following Automatic Start of Four Diesel Generators,Diesel Generator 1 Tripped & Locked Out on Low Lube Oil Pressure. Caused by Air in Sensing Line of Diesel Pressure Switch (← links)
- 05000324/LER-1982-144, Forwards LER 82-144/03L-0 (← links)
- 05000324/LER-1982-142-03, /03L-0:on 821218,PCIV B32-F058B,located at RIP X-241B,found Closed.Caused by Const Personnel Accidently Bumping Valve &/Or Associated Instrument Piping.Valve Opened & Personnel Counseled (← links)
- 05000325/LER-1982-013-03, While Attempting to Open HPCI Sys Steam Supply Outboard PCIV,1-E41-F003,valve Motor Tripped on Magnetics.Caused by Failure of Armature Windings. Motor Rewound & Reinstalled (← links)
- 05000324/LER-1982-081-03, While Performing Friction Testing of Control Rods,Rods 06-23 & 26-27 Not Fully Inserted in Accordance W/Tech Specs.Caused by Personnel Error.All Connectors Rebuilt in 1982 Checked & Tightened (← links)
- 05000324/LER-1982-081, Forwards Updated LER 82-081/03L-1 (← links)
- 05000325/LER-1982-028-03, During Routine Surveillance,Comparison of RTGB Indications of Suppression Chamber Water Level Revealed 2.2-inch Level Difference. Caused by Loss of Trickle Flow Transmitter to Wet Ref Leg (← links)
- 05000325/LER-1982-136-03, Indicator 1-CAC-LI-2601-1 Showed Level of -27 Inches,Indicator 1-CAC-LI-2601-3 Showed Level of -27.5 Inches & Indicator 1-CAC-LR-2602 Showed Level of -29 Inches.Caused by Change in Trickle Flow (← links)
- 05000325/LER-1982-136, Forwards Updated LER 82-136/03L-1 (← links)
- 05000325/LER-1982-056, Forwards Updated LER 82-056/03L-1 (← links)
- 05000325/LER-1982-150, Forwards LER 82-150/03L-0 (← links)
- 05000324/LER-1982-131-03, /03L-0:on 821206,one-half Automatic Reactor Scram Signal Received Due to Instrument Downscale Signal from 2-D12-RM-K603D Main Steam Line Radiation Monitor.Caused by Loss of High Voltage Input to Relay.Cable Reconnected (← links)
- 05000324/LER-1982-131, Forwards LER 82-131/03L-0 (← links)
- 05000324/LER-1982-127-03, /03L-0:on 821206,drywell Oxygen Concentration Exceeded 4% Following Core Auxiliary Cooling (CAC) Sys Failures.Caused by Ruptured Section of CAC Sys Piping. Damaged Piping Section Replaced (← links)
- 05000324/LER-1982-127, Forwards LER 82-127/03L-0 (← links)
- 05000325/LER-1982-044, Supplemental LER 82-044/03L-1:on 820329,RTGB Instrument 1-CAC-LR-2682,indicated Level of -31.5 Inches Below Actual Level.Caused by Change in Trickle Flow to Wet Ref Leg of Recorder Transmitter.Transmitter Recalibr (← links)
- 05000324/LER-1982-136-03, /03L-0:on 821206,primary Containment Atmosphere Oxygen Analyzer 2-CAC-AT-1263-2 Showed Erratic Indication of Drywell Oxygen Containment.Caused by Improperly Installed Diffusion Screen in Analyzer Magnetic Unit (← links)
- 05000324/LER-1982-139-01, /01T-0:on 821216,while Investigating Downscale Indication on Reactor Water Cleanup Differential Flow Indicator,Determined That Three Flow Transmitters Supplying Erroneous Signals to Summer Circuit (← links)
- 05000324/LER-1982-139, Forwards LER 82-139/01T-0 (← links)
- 05000325/LER-1982-126-03, /03L-0:on 821201,primary Containment Atmosphere Oxygen Analyzer 1-CAC-AT-1259-2 Indicated Unexpected Downward Trend in Drywell Oxygen Concentration.Caused by Instrument Zero Shift.Analyzer Recalibr & Returned to Svc (← links)
- 05000325/LER-1982-126, Forwards LER 82-126/03L-0 (← links)
- 05000324/LER-1982-133, Forwards LER 82-133/03L-0 (← links)
- 05000325/LER-1982-134-03, /03L-0:on 821201,primary Containment Atmosphere Oxygen analyzer,1-CAC-AT-1263-2,indicated Step Increase in Drywell Oxygen Concentration.Caused by 1262-2 Analyzer Experiencing Instrument Zero Shift.Analyzer Recalibr (← links)
- 05000325/LER-1982-145, Forwards LER 82-145/03L-0 (← links)
- 05000325/LER-1982-147-03, /03L-0:on 821202,RHR Svc Water Differential Pressure indicator,1-E11-PDI-3344,showed Downscale Indication.Caused by Instrument Drift.Instrument Recalibr (← links)
- 05000325/LER-1982-106-03, /03L-0:on 821026,primary Containment Oxygen Analyzer 1-CAC-AT-1263-2 Indicated Drywell Oxygen Concentration 3% Less than Indicated by Redundant Analyzer 1-CAC-AT-1259.Caused by Instrument Output Shift (← links)
- 05000325/LER-1982-106, Forwards LER 82-106/03L-0 (← links)
- 05000325/LER-1982-135-03, /03L-0:on 821019,1.5-inch Discrepancy Between Narrow & Wide Range Instruments Revealed During Performance of Suppression Pool Level Indicator Operability Test.Caused by Inoperability of RTGB Level Instruments (← links)
- 05000325/LER-1982-135, Forwards LER 82-135/03L-0 (← links)
- 05000325/LER-1982-110, Forwards LER 82-110/03L-0 (← links)
- 05000324/LER-1982-121-03, /03L-0:on 821009,during Low Power Range Monitor Calibr,Isolating Function of a Transient in-core Probe Guide Tube Isolation Ball Valve Became Inoperable.Caused by Drive Tubing Problem.Investigation Continuing (← links)
- 05000325/LER-1982-108-03, /03L-0:on 821010,safety Relief Valve 1B21-F013J Failed to Reclose Until 50-100 Psig Reactor Pressure Reached.Caused by Faulty Spring within Solenoid Valve. Defective Solenoid Valve & Valve Pilot Assembly Replaced (← links)