- 05000320/LER-1998-001, Forwards LER 98-001-00 Re Condition Which Was Evaluated & Determined to Be Reportable on 980615.NRC Form 366 Contains Abstract,Providing Brief Description of Evaluated Condition (← links)
- 05000320/LER-1982-020, Forwards LER 82-020/01L-0 (← links)
- 05000320/LER-1982-023, Forwards LER 82-023/03L-0 (← links)
- 05000320/LER-1982-022, Forwards LER 82-022/03L-0 (← links)
- 05000320/LER-1979-015, Sanitized Version of LER 79-015/13L-1:on 790328,during Investigation of Radwaste & Makeup Sys,Three People Received Radiation Doses in Excess of Quarterly Limit.One Person Received Excess Dose to Skin.Investigation Suspended (← links)
- 05000320/LER-1982-019, Forwards LER 82-019/03L-0 (← links)
- 05000320/LER-1982-018, Forwards LER 82-018/03L-0 (← links)
- 05000320/LER-1982-017, Forwards LER 82-017/03L-0 (← links)
- 05000320/LER-1982-016, Forwards LER 82-016/03L-0 (← links)
- 05000320/LER-1982-015, Forwards LER 82-015/01L-0 (← links)
- 05000320/LER-1989-005-01, :on 890830,operations Personnel Observed That Voltage of Cell 71 of Station Storage Battery Decreased More than 0.1 Volts Below Baseline Voltage Required by Recovery Operation Plan.Caused by Degradation of Cell (← links)
- 05000320/LER-1989-002-01, :on 890506,effluent Monitor in Waste Handling & Packaging Facility out-of-svc & Auxiliary Samples Not Taken During Required Tech Spec Frequency.Caused by Personnel Error.Batteries & Surge Protection Installed (← links)
- 05000320/LER-1989-004-01, :on 890725,failure of 4160/480-volt Transformer Resulted in Action Statement Entry of Tech Spec 3.8.2.1.1. Caused by Degradation of Insulation on Windings on Primary Side.Power Restored to Bus 2-46 w/cross-tie (← links)
- 05000320/LER-1989-003-01, :on 890509,core Alteration Performed W/O Supervision of Fuel Handling Senior Reactor Operator.Caused by Personnel Error in That Task Supervisor Failed to Implement Procedure 4730-IMP-3221.02 (← links)
- 05000320/LER-1987-011-01, :on 871123,Halon Sys Remained Out of Svc Following Completion of Surveillance Per Tech Spec 3.7.10.3 W/O Continuance of Fire Watch.Caused by Personnel Error.Sys Returned to Svc & Personnel Counseled (← links)
- 05000320/LER-1987-010-01, :on 870715,mod to Epicor II Ventilation Sys Radiation Monitor Resulted in Sample Flowrate Monitor Being Changed.Caused by Personnel Error.Personnel Counseled & Surveillance Procedures Being Reviewed (← links)
- 05000320/LER-1998-001-02, :on 980604,flood Barriers Breached Between Turbine Bldg & Control Bldg Area.Caused by Work Planning Process for Dismantlement Work Failed to Include Adequate Controls.Openings Verified to Be Sealed (← links)
- 05000320/LER-1986-001-01, :on 851220,Tech Spec 3.8.1.1 Found Exceeded Due to Emergency Diesel Generator DF-X-1B Out of Svc for More than 7 Days.Caused by Remote Speed Control Problem Due to Leaking Governor & Loose Fittings on Solenoid (← links)
- 05000320/LER-1989-001-01, :on 890120,midi air-lift Vacuum Sys Removed from Reactor Vessel W/O Supervision of Fuel Handling Senior Reactor Operator.Caused by Lack of Communication.Event Will Be Discussed W/All Applicable Personnel (← links)
- 05000320/LER-1987-007-02, :on 870807,abnormal Pressure Indicated on One Halon Cylinder for Cable Room & Transformer Room Halon Sys. Caused by Deficient Solenoid Pilot Valve.Valve Replaced. Procedures Will Be Modified (← links)
- 05000320/LER-1986-006, :on 860715,contaminated Camera Tripod Discovered in Dumpster in Unrestricted Area.Caused by Failure of Unknown Personnel to Implement Controls When Transferring Matl.Tripod Decontaminated (← links)
- 05000320/LER-1986-006-02, :on 860715,discovered Contaminated Camera Tripod in Scrap Metal Dumpster in Unrestricted Area.Caused by Personnel Error.Tripod & Dumpster Decontaminated & Dumpster Resurveyed on 860716 (← links)
- 05000320/LER-1986-012-02, :on 861214,sprinkler Nozzle (IEEE Code Nzl) for Control Room Bypass Charcoal Filter AH-F-5 Logged Inoperable.Caused by Personnel Error.Nozzle Cleaned,Retested & Returned to Svc (← links)
- 05000320/LER-1987-001-02, :on 870123,return to Svc Criteria of Procedure 4210-SUR-3811 Not Performed Properly.Caused by Personnel Error.Procedure Revised to Identify Required Actions (← links)
- 05000320/LER-1986-010-02, :on 860930,radiological Controls Technician Discovered AMS-3 at Reactor Bldg Equipment Hatch Exhibiting Failure Light.Caused by Personnel Error.Faulty Detector Replaced & One Hatch Door Closed (← links)
- 05000320/LER-1986-008-02, :on 860828,nonperformance of May 1986 Monthly Surveillance Test for Fire Suppression Water Sys Valve Lineup Verification Noted.Caused by Personnel Error. Personnel Counseled (← links)
- 05000320/LER-1986-009-02, :on 860904,control Room Bypass Filter AH-F-5 Deluge Sys Isolated by Tagging Out Valve FS-V-507 W/O Hourly Fire Watch.Caused by Personnel Error.Personnel Counseled & Procedure Revised (← links)
- 05000320/LER-1986-011-02, :on 861207,during Replacement of Charcoal filters,16 Deluge Sys Fire Detectors for Fuel Handling Bldg Exhaust Filter AH-F-14A/B Inoperable.Caused by Personnel Error.Hourly Fire Watch Established (← links)
- 05000320/LER-1988-010-01, :on 880610 & 23,automatic Cutting Equipment Sys Plasma Arc Torch Operated While Reactor Bldg Purge Sys Not Operating.Caused by Personnel Failure.Operating Procedure 4210-OPS-3255.29 Revised (← links)
- 05000320/LER-1987-004-01, :on 870228,Tech Spec 3.3.3.4 Requiring Operability of Control Room Meteorological Instrumentation Violated.Caused by Inoperable Air Temp Delta T Recorder Due to Inadequate Surveillance Frequency (← links)
- 05000320/LER-1987-003-01, :on 870226,load Consisting of Four Empty Defueling Canisters Weighing Approx 9,000 Lbs Transferred from 305 Ft Elevation to Storage.Caused by Personnel Error. Load Lift Completed & Load Placed in Storage (← links)
- 05000320/LER-1986-007-02, :on 860727,grab Sample Not Taken & Analyzed within Tech Spec Limit of 24 H.Caused by Declaring Epicor II Ventilation Sys Monitor Inoperable on 860724.Another Grab Sample Obtained (← links)
- 05000320/LER-1988-008-01, :on 880504,trash Bags Containing Matl Contaminated to Levels of Up to 35,000 Dpm Discovered.Caused by Unforseen Condition Resulting from Housekeeping Activity. Similar Event Occurred on 880508.Bags Surveyed (← links)
- 05000320/LER-1988-009, :on 880513,flushing Operation Performed Using Borated Water Storage Tank/Fuel Transfer Canal Fill Sys. Caused by Personnel Error.Flushing Activity Terminated & Control Room Notified (← links)
- 05000320/LER-1986-004, :on 860224,number of Transfers of Expended Filter Media to Holding Drum Exceeded Limit in Ser.Caused by Failure to Incorporate SER Transfer Limits Into Procedure. Procedure Revised (← links)
- 05000320/LER-1988-007-01, :on 880428,one of Two Reactor Bldg Personnel Airlock Doors Maintained in Closed Position.Caused by Personnel Error.Airlock Attendants Advised to Maintain Both Doors Closed Unless Transit Exit in Progress (← links)
- 05000320/LER-1988-005-01, :on 880421,removal of Trash from Radiologically Controlled Area in Excess of Established Limits W/O Proper Release Surveys.Caused by Lack of Awareness Requirements. Contaminated Matl Isolated & Analyzed (← links)
- 05000320/LER-1988-011, :on 880807,control Room Personnel Failed to Recognize Requirements to Enter Action Statement.Caused by Misunderstanding of Requirements of Tech Spec 3.8.1.1. Event Discussed W/Operators (← links)
- 05000320/LER-1986-002-01, :on 860103,discovered Containment Isolation Valve DW-V-139 Open.Cause Not Identified.Valve Locked Closed.As Precautionary Measure,Double Valve Isolation Outside Containment Will Be Maintained (← links)
- 05000320/LER-1985-010-01, :on 850501,annual Cycling of Fire Suppression Water Sys Valves Not Completed on Time.Caused by Personnel Error Due to Lack of Adequate Communication.Overdue Surveillance Immediately Commenced (← links)
- 05000320/LER-1988-003, :on 880126,wind Speed Recorder in Control Room Declared Inoperable.Caused by Adverse Weather Conditions. Weather Improved Next Day & Recorder Restored to Operable Status (← links)
- 05000320/LER-1988-001, :on 880106,discovered That Drill Indexing Platform Structure Inversely Installed.Caused by Personnel Error.Support Structures Reinstalled Correctly & Unit Work Instruction Revised (← links)
- 05000320/LER-1988-002, :on 880112,auxiliary Bldg Fire Detection Instrumentation Inoperable When Ventilation Secured & No Firewatch Initiated.Caused by Personnel Error.Personnel Counseled & Procedures Revised (← links)
- 05000320/LER-1987-012-01, :on 871009,indications of Failure of Locknut & Stemnut for Isolation Valve DH-V-4V Discovered.Caused by Failure to Stake Locknut & Drive Sleeve Assembly.Locknut & Sleeve Assembly Replaced & Locknut Staked (← links)
- 05000320/LER-1986-003-01, :on 851117,fuel Handling Bldg Exhaust Monitors HPR-221A & HPR-221B Not Tested within Required Interval,Per Tech Spec 3.3.3.1.Caused by Personnel Error.Monitors Successfully Tested (← links)
- 05000320/LER-1986-001, :on 851220,no Remote Speed Control Existed on Emergency Diesel Generator DF-X-1B.Caused by Defective Solenoid in Replacement Governor.Governor & Solenoid Returned to Mfg for Analysis (← links)
- 05000320/LER-1984-017, :on 841024,sonar Insp of Flood Protection Dike Revealed Degradation of Submerged Toe in Vicinity of River Water Pump Houses.Sept 1985 Insp Revealed Same Degradation. Baseline Degradation Criteria Changed (← links)
- 05000320/LER-1985-009-01, :on 851105,during Valve line-up for Processing Fuel Transfer Canal Water,Containment Isolation Valve DWC-V-099 Discovered in Open Position Since 851103.Caused by Personnel Error (← links)
- 05000320/LER-1985-001, :on 850104,survey Results Indicated Minor Degradation of Flood Protection Dike.Caused Not Stated. Degradation Minor & No Corrective Actions Necessary at Present (← links)
- 05000320/LER-1985-008-01, :on 850801,fire Sys Valve FS-V-137 Closed. Caused by Personnel Failure to Recognize That Closing Valve Would Isolate Area Fire Suppression Deluge/Sprinkler Sys. Fire Suppression Sys Restored (← links)