- 05000324/LER-1979-070-03, /03L-0:on 790926,rod Drift Alarm Annunciated for Rod 22-31.Indication for Position Was No Longer Illuminated. Caused by Problem in Prototypic Inlet Piping Probe Located in Drywell + (14:39:43, 4 January 2025)
- 05000333/LER-1979-077, Forwards LER 79-077/04L-0 + (14:39:45, 4 January 2025)
- ML19250A509 + (14:39:46, 4 January 2025)
- 05000302/LER-1979-088-03, /03L-0:on 790918,gaseous Release Monitor RMA-1 Was Found Isolated.Caused by Personnel Error.Monitor Not Properly Returned to Svc Following Filter Replacement. Revision Is Being Made + (14:39:48, 4 January 2025)
- ML19250A506 + (14:39:49, 4 January 2025)
- TXX-3022, Forwards Itt Grinnell Engineering Std ES-13 in Response to IE Bulletin 79-02, Pipe Support Base Plate Designs Using Concrete Expansion Anchor Bolt + (14:39:50, 4 January 2025)
- 05000302/LER-1979-088, Forwards LER 79-088/03L-0 + (14:39:53, 4 January 2025)
- 05000333/LER-1979-066-03, /03X-1:on 790907,while Conducting Operations Surveillance Test,Average Power Range Monitor Channels A,D & F Tripped 0.5% Over Tech Spec Requirements.Caused by Operator Error.No Drift of Instrument Setpoint Occurred + (14:39:55, 4 January 2025)
- 05000282/LER-1979-027-01, /01T-0:on 791002,tube Break Occurred in Steam Generator 11.Caused by Mechanical Wear.Two Defective Tubes Plugged + (14:39:56, 4 January 2025)
- 05000333/LER-1979-066, Forwards LER 79-066/03X-1 + (14:40:01, 4 January 2025)
- 05000368/LER-1979-080-03, /03L-0:on 790921,indication for Sodium Hydroxide Addition Tank Discharge Valve 2CV-5667-2 Was Lost.Caused by Failed Power Supply Fuse.Power Fuse Was Replaced & Control Circuit Current Verified + (14:40:07, 4 January 2025)
- ML19250A491 + (14:40:09, 4 January 2025)
- 05000336/LER-1979-029-03, /03L-0:on 790919,B Hydrogen Analyzer Alarms Failed to Clear,Making Detection of Sensor Failure Impossible & Resulting in Hydrogen Analyzer Inoperability.Caused by Failure of Operational Amplifier in Alarm Card + (14:40:10, 4 January 2025)
- 05000324/LER-1979-070, Forwards LER 79-070/03L-0 + (14:40:12, 4 January 2025)
- ML19250A484 + (14:40:14, 4 January 2025)
- 05000336/LER-1979-029, Forwards LER 79-029/03L-0 + (14:40:16, 4 January 2025)
- ML19250A476 + (14:40:17, 4 January 2025)
- 05000334/LER-1979-038-03, /03L-0:on 790918,vital Bus Inverter 4 Output Frequency Observed Spiking Upscale.Caused by Faulty Oscillator Card in Inverter Control Logic.Inverter Repaired & Returned to Svc + (14:40:19, 4 January 2025)
- 05000334/LER-1979-038, Forwards LER 79-038/03L-0 + (14:40:20, 4 January 2025)
- 05000267/LER-1979-038-03, /03L-0:on 790921,analytical Sys Primary Coolant Moisture Monitor ME-9307 Became Inoperable W/Reactor at Less than 2% Power.Caused by Burned Out Thermal Electric Heater/Cooler & Two Faulty Relays.Head & Relays Replaced + (14:40:22, 4 January 2025)
- ML19250A468 + (14:40:24, 4 January 2025)
- 05000267/LER-1979-038, Forwards LER 79-038/03L-0 + (14:40:25, 4 January 2025)
- 05000259/LER-1979-024-03, /03L-0:on 791018,during Normal Operation,Radiation Monitor RM-90-250 Found Erratic & Taken Out of Svc for 1.5-h.Caused by Moisture Collection in Model SC-2B Detector. No Recurrence Control Action Planned + (14:40:27, 4 January 2025)
- 05000259/LER-1979-024, Forwards LER 79-024/03L-0 + (14:40:29, 4 January 2025)
- 05000267/LER-1979-037-03, /03L-0:on 790919,during Normal Operation,Liquid Radwaste Release Was Made in Noncompliance W/Limiting Conditions for Operation.Caused by Operator Failure to Reset Flow Switch to New Required Flow Rate.Operators Admonished + (14:40:31, 4 January 2025)
- 05000267/LER-1979-037, Forwards LER 79-037/03L-0 + (14:40:33, 4 January 2025)
- 05000348/LER-1979-040-01, /01T-0:on 791011,wrong Valves Installed in Piping Sys.Caused by Deficiency in Original Plant Design Equipment Specs.Valves Being Replaced + (14:40:34, 4 January 2025)
- 05000348/LER-1979-040, Forwards LER 79-040/01T-0 + (14:40:43, 4 January 2025)
- 05000333/LER-1979-076-03, /03L-0:on 790925,after Protracted Shutdown of Six Months,Reactor Water Conductivity Indicated Increase from Normal Range of Less than 1 Umho/Cm.Caused by Exhaustion of Condensate Demineralizer & Condenser Tube Leaks + (14:40:45, 4 January 2025)
- 05000333/LER-1979-076, Forwards LER 79-076/03L-0 + (14:40:48, 4 January 2025)
- ML19250A450 + (14:40:49, 4 January 2025)
- ML19250A452 + (14:40:49, 4 January 2025)
- ML19250A447 + (14:40:50, 4 January 2025)
- ML19250A446 + (14:40:50, 4 January 2025)
- ML19250A445 + (14:40:51, 4 January 2025)
- ML19250A443 + (14:40:51, 4 January 2025)
- ML19250A442 + (14:40:53, 4 January 2025)
- ML19250A441 + (14:40:53, 4 January 2025)
- ML19250A440 + (14:40:54, 4 January 2025)
- ML19250A438 + (14:40:55, 4 January 2025)
- ML19250A436 + (14:40:56, 4 January 2025)
- ML19250A437 + (14:40:56, 4 January 2025)
- ML19250A435 + (14:40:57, 4 January 2025)
- 05000267/LER-1979-039-03, /03L-0:on 790924,authorized Liquid Waste Release Was Made,Requiring Raising Setpoints on Liquid Waste Activity Monitors Above Normal.Caused by Failure to Return Monitors to Normal Setpoints Prior to Starting Release + (14:40:58, 4 January 2025)
- ML19250A430 + (14:41:00, 4 January 2025)
- ML19250A431 + (14:41:00, 4 January 2025)
- ML19250A429 + (14:41:01, 4 January 2025)
- ML19250A426 + (14:41:02, 4 January 2025)
- ML19250A425 + (14:41:03, 4 January 2025)
- ML19250A423 + (14:41:04, 4 January 2025)
- ML19250A424 + (14:41:04, 4 January 2025)