Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19345B533 + (15:17:40, 24 December 2024)
- ML19345B532 + (15:17:42, 24 December 2024)
- ML19345B531 + (15:17:43, 24 December 2024)
- ML19345B530 + (15:17:50, 24 December 2024)
- ML19345B529 + (15:17:57, 24 December 2024)
- ML19345B528 + (15:18:03, 24 December 2024)
- 05000282/LER-1980-033-03, /03L-0:on 801028,steam Flow Transmitter 1FT-464 Observed Reading Low.Caused by Zero Adjustment Shift in Barton Model 384 Differential Pressure Transmitter.Device Recalibr + (15:18:06, 24 December 2024)
- ML19345B526 + (15:18:18, 24 December 2024)
- 05000282/LER-1980-033, Forwards LER 80-033/03L-0 + (15:18:22, 24 December 2024)
- ML19345B521 + (15:18:28, 24 December 2024)
- ML19345B520 + (15:18:29, 24 December 2024)
- ML19345B519 + (15:18:35, 24 December 2024)
- ML19345B517 + (15:18:41, 24 December 2024)
- ML19345B518 + (15:18:41, 24 December 2024)
- ML19345B516 + (15:18:49, 24 December 2024)
- ML19345B515 + (15:18:50, 24 December 2024)
- ML19345B514 + (15:18:56, 24 December 2024)
- ML19345B512 + (15:19:02, 24 December 2024)
- ML19345B513 + (15:19:02, 24 December 2024)
- ML19345B510 + (15:19:08, 24 December 2024)
- ML19345B509 + (15:19:09, 24 December 2024)
- ML19345B507 + (15:19:14, 24 December 2024)
- ML19345B504 + (15:19:16, 24 December 2024)
- 05000271/LER-1980-039-03, /03L-0:on 801025,valves V16-20-20 & LRW-83 Found to Have Seat Leakage in Excess of Tech Specs.Cause Not Stated.Valves Repaired + (15:19:19, 24 December 2024)
- ML19345B496 + (15:19:34, 24 December 2024)
- 05000321/LER-1980-111-03, /03L-0:on 801106,automatic Depressurization Sys Reactor Water Level Switch 1B21-N042A Actuated Above Tech Specs.Caused by Component Failure Due to Galling of Range Adjusting Screw.Level Switch Replaced + (15:19:35, 24 December 2024)
- 05000255/LER-1980-043-01, /01T-0:on 801106,measured Leakage Through Containment Penetration 14 Exceeded Tech Spec Limit.Cause Under Evaluation.Check Valve & Butterfly Valve Seat Replaced + (15:19:40, 24 December 2024)
- 05000338/LER-1980-095-03, /03L-0:on 801027,fire Doors S71-7,-17 & -19 Found Nonfunctional Due to Inability to Fully Close & Latch on Free Swing from Full Open.Caused by Excessive Use.Doors Temporarily Repaired & New Design Submitted + (15:19:42, 24 December 2024)
- ML19345B491 + (15:19:48, 24 December 2024)
- 05000254/LER-1980-028-03, /03L-0:on 801023,diesel Generator Cooling Water Pump Motor 1/2 Found two-thirds Submerged in Water.Caused by Inadequate Vault Sump Pump Sys.Vault Drained & Cooling Water Pump Motor Replaced + (15:19:58, 24 December 2024)
- 05000368/LER-1979-022-99, Changes in Control Circuitry of Containment Cooling Fans Discovered Inadvertently Omitted.Caused by Oversight.Mods Completed + (15:20:00, 24 December 2024)
- 05000271/LER-1980-039, Forwards LER 80-039/03L-0 + (15:20:01, 24 December 2024)
- 05000338/LER-1980-095, Forwards LER 80-095/03L-0 + (15:20:03, 24 December 2024)
- 05000321/LER-1980-111, Forwards LER 80-111/03L-0 + (15:20:05, 24 December 2024)
- 05000254/LER-1980-028, Forwards LER 80-028/03L-0 + (15:20:07, 24 December 2024)
- 05000338/LER-1980-096-01, /01T-0:on 801114,S&W Determined Significant out-of -phase Transfer Could Occur When Emergency Buses Transferred to Emergency Diesel Generators.Cause Not Determined.Time Delay Circuit Installed on Generators + (15:20:09, 24 December 2024)
- 05000266/LER-1980-013-01, /01T-0:on 801113,suction to 1P4B Boric Acid Transfer Pump Isolated,Rendering Pump Inoperable.Probably Caused by Personnel Error in Returning Valve Lineup to Normal Following Recirculation & Sampling + (15:20:10, 24 December 2024)
- 05000368/LER-1979-022, Forwards Updated LER 79-022/99X-1 + (15:20:15, 24 December 2024)
- 05000317/LER-1980-061-03, /03L-0:on 801024,emergency Diesel Generator 11 Would Not Carry Greater than 2,500 Kw for Greater than 60 Minutes.Caused by High Cylinder Temp Due to Fouling of Injector Tips.Tips Replaced + (15:20:17, 24 December 2024)
- 05000348/LER-1980-065-03, /03L-0:on 801022,total Controlled Leakage During Reactor Coolant Pump Seal Controlled Leakage test,FNP-1-STP- 8.0,exceeded Tech Spec Limit.Caused by Failure to Verify Total Flow After Adjustment.Operating Procedure Changed + (15:20:18, 24 December 2024)
- 05000266/LER-1980-013, Forwards LER 80-013/01T-0 + (15:20:20, 24 December 2024)
- 05000338/LER-1980-096, Forwards LER 80-096/01T-0 + (15:20:22, 24 December 2024)
- 05000339/LER-1980-083-03, /03L-0:on 801027,F(Q) Limit Exceeded Twice.Caused by Rod Movement at Beginning of Core Life When F(Q) Limit Margins in Core Ctr Are at Min.Power Reduced + (15:20:24, 24 December 2024)
- 05000339/LER-1980-076-03, /03L-0:on 801106,steam Generator Level Transmitter LT-486 Gave High Indication of 4.7%.Caused by Instrument Drift.Transmitter Recalibr + (15:20:32, 24 December 2024)
- 05000366/LER-1980-146-03, /03L-0:on 801029,excessive Noise & Vibration Observed from 1R43-5001B,emergency Diesel Generator.Caused by Scavenging Air Blower.Blower Replaced + (15:20:34, 24 December 2024)
- 05000317/LER-1980-061, Forwards LER 80-061/03L-0 + (15:20:36, 24 December 2024)
- 05000339/LER-1980-083, Forwards LER 80-083/03L-0 + (15:20:39, 24 December 2024)
- 05000339/LER-1980-076, Forwards LER 80-076/03L-0 + (15:20:43, 24 December 2024)
- 05000366/LER-1980-146, Forwards LER 80-146/03L-0 + (15:20:44, 24 December 2024)
- 05000348/LER-1980-065, Forwards LER 80-065/03L-0 + (15:20:46, 24 December 2024)
- 05000293/LER-1980-086-04, /04L-0:on 801024,condenser Delta T Exceeded Tech Spec Limit.Caused by Increasing Sea Water Temp & Lowering Tide Level + (15:20:48, 24 December 2024)