- ML20027A423 + (03:12:57, 21 December 2024)
- ML20027A422 + (03:12:58, 21 December 2024)
- ML20027A421 + (03:13:00, 21 December 2024)
- ML20027A420 + (03:13:01, 21 December 2024)
- ML20027A418 + (03:13:02, 21 December 2024)
- ML20027A417 + (03:13:03, 21 December 2024)
- ML20027A415 + (03:13:03, 21 December 2024)
- ML20027A414 + (03:13:04, 21 December 2024)
- 05000346/LER-1978-106-03, /03L-0:on 781026,after Maint Completed on 781013, Operations Personnel Stroked FW 612 & Returned to Svc W/O Noting Isolation Time Data.Caused by Peronnel Error. Personnel Advised to Monitor Repair Activites Carefully + (03:13:05, 21 December 2024)
- 05000346/LER-1978-106, Forwards LER 78-106/03L-0 + (03:13:07, 21 December 2024)
- ML20027A410 + (03:13:09, 21 December 2024)
- ML20027A408 + (03:13:11, 21 December 2024)
- ML20027A406 + (03:13:12, 21 December 2024)
- ML20027A405 + (03:13:13, 21 December 2024)
- ML20027A402 + (03:13:14, 21 December 2024)
- ML20027A401 + (03:13:15, 21 December 2024)
- 05000265/LER-1978-035-03, /03L-0 on 781004:Unit 2A Reactor Vent Radiat Monitor & 2A Refueling Floor Radiat Monitor Started Spuriously Spiking.Caused by Faulty Pwr Supply Common to Both 2A Monitors.Pwr Supply Replaced W/Spare Monitor + (03:13:17, 21 December 2024)
- 05000265/LER-1978-035, Forwards LER 78-035/03L-0 + (03:13:18, 21 December 2024)
- 05000265/LER-1978-032-03, /03L-0 on 780929:Unit 2 Main Steam Target Rock Pressure Relief Valve 2-203-3A Failed to Open While Performing Test.Caused by Broken Air Line to Valves Manual Air Operator + (03:13:20, 21 December 2024)
- 05000265/LER-1978-032, Forwards LER 78-032/03L-0 + (03:13:22, 21 December 2024)
- 05000237/LER-1978-051-03, /03X-1 on 780907:during Surveillance Test Dis 1600-11,valve 2-1601-24 Failed to Operate in Specified Time Limit.Caused by Foreign Matter Lodged in Solenoid Operated 4 Way Valve,Preventing Proper Bleed Off + (03:13:23, 21 December 2024)
- 05000265/LER-1978-034-03, /03L-0 on 781002:while Performing Procedure Qts 130-4,Control Rod Drive Scam Timing Control Rod N-10(50-39) Failed to Scram Upon Receiving a Test Signal from Panel 902- 16.Caused by Failure of 118 Scram Solenoid Valve + (03:13:25, 21 December 2024)
- 05000265/LER-1978-034, Forwards LER 78-034/03L-0 + (03:13:27, 21 December 2024)
- ML20027A389 + (03:13:28, 21 December 2024)
- 05000265/LER-1978-033-03, /03L-0 on 780930:during Routine Snubber Surveillance inspec,2 Snubbers Were Found to Be Inoperable. Both Mark 183 & Mark 175 Snubbers Failed Due to Hydraulic Leakage Thru Hardened O-rings + (03:13:29, 21 December 2024)
- 05000265/LER-1978-033, Forwards LER 78-033/03L-0 + (03:13:31, 21 December 2024)
- 05000265/LER-1978-036-03, /03L-0 on 781016: 1 Core Spray low-low Level Initation Switch Failed to Trip at Proper Setpoint, Caused by Instru Drift + (03:13:32, 21 December 2024)
- 05000265/LER-1978-036, Forwards LER 78-036/03L-0 + (03:13:34, 21 December 2024)
- 05000266/LER-1978-010-01, /01T-1 on 780528:Indication of primary-to- Secondary Leak of 145 Gpd in the a SG Was Noted on 780524. Source of Leak Due to Failure of Tube at Position R44C35. Tube Plugged & Unit Returned to Svc + (03:13:36, 21 December 2024)
- ML20027A380 + (03:13:37, 21 December 2024)
- ML20027A379 + (03:13:38, 21 December 2024)
- IR 05000266/1978015 + (03:13:43, 21 December 2024)
- ML20027A376 + (03:13:45, 21 December 2024)
- ML20027A375 + (03:13:45, 21 December 2024)
- 05000346/LER-1977-089-03, /03L-1:on 771107,radiation Monitor RIS 2007 Was Showing Erratic Readings.Caused by Victoreen Low Range Amplifier Board 847-1-20 Failure.Board Replaced + (03:13:46, 21 December 2024)
- 05000346/LER-1978-024-03, /03L-1:on 780228,MSIV MS-101 Rendered Inoperable to Allow Maint Personnel to Remove Raised Metal on Two of Four Spring Guide Tubes.Cause of Raised Metal Unknown.Metal Filed Down,Valve Closing Time Adjusted & Valve Tested + (03:13:50, 21 December 2024)
- ML20027A370 + (03:13:51, 21 December 2024)
- ML20027A368 + (03:13:53, 21 December 2024)
- 05000346/LER-1978-016-03, /03L-1:on 780202,absolute Position Indicator for Group 5,Rod 12,declared Inoperable.Caused by Component Failure in Penetration Area.Containment Conductors Connected to Spare Penetration Connector + (03:13:56, 21 December 2024)
- 05000346/LER-1978-021-03, /03L-1:on 780220,absolute Position Indicator for Control Rod 12 of Group 5 Declared Inoperable.Caused by Component Failure in Penetration Area.Conductors Connected W/Spare Penetration Connectors + (03:13:58, 21 December 2024)
- 05000346/LER-1978-016, Forwards LER 78-016/03L-1,LER 78-021/03L-1,LER 78-100/03L-1, LER 78-034-03L-1 & LER 78-024/03L-1 + (03:14:00, 21 December 2024)
- 05000338/LER-1978-118-99, /99T-0 on 781007:seismic Alarms Associated W/ Containment Mat Vertical Sensors Actuated W/No Other Indication of Seismic Disturbance.Cause Unknown.Vertical Recorder Will Be Repaired or Replaced + (03:14:02, 21 December 2024)
- ML20027A357 + (03:14:06, 21 December 2024)
- ML20027A356 + (03:14:07, 21 December 2024)
- ML20027A354 + (03:14:08, 21 December 2024)
- 05000237/LER-1978-058-03, /03L-0 on 781018:LPCI Suction Valve MO-2-1501-5C Failed to Close During Operability Test.Failure Traced to Valve Stem Not Being Adequately Lubricated.Lubrication Interval Shortened + (03:14:09, 21 December 2024)
- ML20027A352 + (03:14:10, 21 December 2024)
- ML20027A351 + (03:14:11, 21 December 2024)
- 05000346/LER-1978-105-03, /03L-0:on 781021,during Surveillance Testing, Control Room Emergency Ventilation Sys Isolation Damper HV-5301A Would Not Close.Caused by Dirt on Sealing Surface & Seals Needing Lubrication.Damper Seals Cleaned & Lubricated + (03:14:12, 21 December 2024)
- 05000346/LER-1978-105, Forwards LER 78-105/03L-0 + (03:14:13, 21 December 2024)
- ML20027A346 + (03:14:15, 21 December 2024)