- 05000361/LER-1982-159, Forwards Updated LER 82-159/03L-1.Detailed Event Analysis Submitted +
- 05000416/LER-1982-159, Forwards LER 82-159/03L-0 +
- 05000327/LER-1983-159-03, /03L-0:on 831110,waste Gas Decay Tank D Had High Oxygen Concentration of 2.3%.On 831111,gas Decay Tank a Concentration Was 2.1%.Cause Unknown.Investigation Continuing +
- 05000387/LER-1983-159-03, /03L-0:on 831126,dual Indication Received When Valve SV-15736A Placed in Closed Position.Caused by Infrequent Valve Operation.Cycling Frequency Will Be Increased If Necessary +
- 05000416/LER-1983-159-03, /03L-0:on 831007,source Range Monitor Control Rod Block Weekly Functional Test Not Performed.Caused by Operations Personnel Erroneously Determining That Surveillance Not Required.Test Performed +
- 05000416/LER-1982-159-03, /03L-0:on 821206,QA Audit Revealed That on 821025, While in Mode 3 (Hot Shutdown),No Shutdown Cooling Mode Loops Were in Operation.Cause Not Stated.Shutdown Cooling Loop Put Into Operation +
- 05000361/LER-1982-159-03, Pressure Indicator 2PI-8300 for Steam Generator E-088 on Essential Plant Parameter Monitoring Sys Panel 21-411 Read Greater than Similar Indicator on Control Room Panel CR-52.Cause Unknown +
- 05000327/LER-1981-159-03, /03L-0:on 811221,auxiliary Feedwater Pressure Control Valve 1-PCV-3-132 Failed to Respond During Performance of SI-166.1.Caused by Failure of Hydraulic Pump on Valve Operator to Deliver Discharge Pressure +
- 05000327/LER-1981-159, Forwards LER 81-159/03L-0 +
- 05000369/LER-1981-159, Forwards LER 81-159/03L-0 +
- 05000369/LER-1981-159-03, /03L-0:on 810915,while in Mode 3,boron Injection Tank Discharge Isolation Valve Began Binding While Opening After Adjustment to Packing.Cause Undetermined.Packing Loosened & Valve Cycled Manually.Motor Replaced +
- 05000327/LER-1980-159-01, /01T-0:on 801015,util Notified That Major Feedwater Line Rupture on Either Steam Generator 3 or 4 Concurrent W/Loss of Channel 1-I Vital Instrument Power Could Prevent Auxiliary Feedwater Sys from Operating +
- 05000327/LER-1980-159, Forwards LER 80-159/01T-0 +
- 05000302/LER-1977-159-03, /03L-0:on 771228,reactor Bldg Purge Exhaust Valve AHV-1B Did Not Auto Close Upon Reactor Bldg Purge Initiation.Caused by Purge Exhaust Valve AHV-1B Not Being Open Enough to Activate Automatic Closure Matrix +
- 05000302/LER-1977-159, Forwards LER 77-159/03L-0 +
- 05000366/LER-1980-159, Forwards Updated LER 80-159/03X-1 +
- 05000366/LER-1980-159-03, During Manual Start Test, Diesel Generator 2C Failed.Caused by Broken Cotter Pins That Lock Connecting Rod Nuts in Place for Cylinder 11,allowing Separation from Crankshaft.Engine Repaired +