Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000361/LER-1982-149, Forwards LER 82-149/03L-0.Detailed Event Analysis Submitted +
- 05000325/LER-1982-149, Forwards LER 82-149/01T-0 +
- 05000416/LER-1982-149, Forwards LER 82-149/03L-0 +
- 05000373/LER-1982-149, Forwards LER 82-149/03L-0 +
- 05000361/LER-1983-149-03, /03L-0:on 850305,two 125-volt Batteries Initially Tested on 820206 & 0702 Determined Not load-tested within Test Interval Prior to Dec 1983.Caused by Personnel Error. Mgt Controls Improved +
- 05000373/LER-1983-149-03, /03L-0:on 831207,setpoint for Reactor Low Water Level Switch 1B21-N024C Exceeded Tech Spec Value.Cause Could Not Be Determined.Switch Immediately Recalibr +
- 05000387/LER-1983-149-03, /03L-0:on 831102,emergency Svc Water Pump B Failed to Start Manually,Resulting in Unit Entering Limiting Conditions for Operation.Caused by Failure of Breaker for Essential Svc Water Pump B to Close +
- 05000416/LER-1983-149-03, /03L-0:on 830927,Channel a Fuel Handling Area Radiation Monitor Operated Erratically Causing High Alarm. Caused by Failed Tube in Detector.Tube Assembly Replaced +
- 05000366/LER-1983-149-03, /03L-0:on 831229,while Transporting Injured Person,Both Doors of Airlock for Reactor Bldg Were Opened, Rendering Secondary Containment Inoperable.Caused by Personnel Error.Airlock Doors Reclosed +
- 05000373/LER-1982-149-03, /03L-0:on 821112,lake Blowdown Flow Recorder Discovered Giving Incorrect Readings.Caused by Algae Buildup on Instrument Probe.Probe Cleaned & Weekly Functional Test Will Be Performed +
- 05000325/LER-1982-149-01, /01T-0:on 821209,limiting Conditions for Operation Initiated on Primary Containment Isolation Sys Instrument 1-B21-PDTM-N006-D-1 Due to Downscale Indications.Caused by Operator Error.Signal Reinserted +
- 05000416/LER-1982-149-03, /03L-0:on 821129,QA Audit Revealed That Beginning on 820923,during Periods When Plant in Hot Shutdown, Containment to Auxiliary Bldg Differential Pressure Verified Every 24 H Instead of Every 12 H.Caused by Personnel Error +
- 05000361/LER-1982-149-03, /03L-0:on 821123,during Mode 1,while Attempting to Shift Steam Generator Feedwater from Auxiliary Feed to Main Feed,Containment Isolation Valve 2HV4730 Would Not Close. Caused by Failure of Limit Switch.Switch Adjusted +
- 05000327/LER-1981-149-03, /03L-0:on 811209,w/unit at 2245 Cst,Steam Generator Blowdown Effluent Line Radiation Monitor Declared Inoperable Due to Erratic Readings.Caused by Pulsating Sample Flow Through Monitor +
- 05000327/LER-1981-149, Forwards LER 81-149/03L-0 +
- 05000369/LER-1981-149-03, /03L-0:on 810828,w/fire Protection Sys Jockey Pumps Unable to Maintain Normal Header Pressure,Fire Pump a Would Not Start.Caused by Antipump Controls Receiving Both Open & Close Signals.Pressure Switch Reset +
- 05000369/LER-1981-149, Forwards LER 81-149/03L-0.Detailed Event Analysis Encl +
- 05000311/LER-1982-149-03, /03L-0:on 821228,during Surveillance on Svc Water Pump 21,discharge Strainer Differential Pressure Exceeded Limits.Caused by Grassy Debris & Silt Plugging Strainer. Strainer Cleaned +
- 05000327/LER-1980-149-03, /03L-0:on 800807,during Preoperational Tests, Turbine Driven Feedwater Pump Failed to Maintain Rated Rpm. Caused by Overheated Automatic Governor.Ventilation Damper Linkage Repaired & Governor Controls Replaced +
- 05000327/LER-1980-149, Forwards LER 80-149/03L-0 +
- 05000338/LER-1979-149, Updates LER-79-149/01T-0 Submitted 791115:exhaust Ductwork from Safeguards Area Ventilation Sys Does Not Conflict W/ FSAR Design Basis.Mods to Ensure Adequate Seismically Qualified Emergency Cooling Expected by 800115 +
- 05000338/LER-1979-149-01, /01T-0:on 791031,discovered That Safeguards Area Exhaust Sys Providing post-LOCA Ambient Cooling for Recirculation Spray & Low Head Safety Injection Pumps Not Entirely Seismically Designed.Cause Unknown +
- 05000366/LER-1980-149, Forwards Updated LER 80-149/03X-1 +
- 05000366/LER-1980-149-03, RHR Pump Suction Isolation Valve 2E11-F4B Was Found Leaking.Caused by Scratches on Valve Seat,Probably Due to Valve Closing on Debris.Valve Seat Polished +