- ENS 40104 +
- ENS 46613 +
- IR 05000286/2010005 +
- IR 05000247/2010005 +
- ML17318A675 +
- ML17317A936 +
- ML110190640 +
- ML063040295 +
- ML18078A862 +
- 05000280/LER-1990-017, :on 901202,loss of 4,160-volt Transfer Bus F Occurred.Caused by Personnel Error.Appropriate Training & Procedural Enhancements Are Being Undertaken +
- RS-06-160, Request for Emergency Amendment to Control Room Ventilation System Technical Specification +
- ENS 46400 +
- ML022460095 +
- ML20086A635 +
- ML20079M246 +
- ML20084T967 +
- ML20135H316 +
- 05000341/LER-1989-015, :on 890707,power Lost to Div I Reactor Protection Sys Bus a Due to Motor Generator Overvoltage Condition.Caused by Single Phase Sensing Potentiometer. Component Replaced W/Fixed Resistor +
- 05000313/LER-1987-006-01, :on 871103,discovered Penetration Room Ventilation Sys Surveillance Not Performed Prior to Establishing Reactor Bldg Integrity.Caused by Inadequate Procedural Guidance.Procedure to Be Revised +
- 05000412/LER-1989-002, :on 890119,control Room Bottled Air Pressurization Sys Actuated When Chlorine Detector B Tripped.Caused by Probe Carrier Absorbing Chlorine from Test Rig.Emergency Air Bottles Isolated +
- 05000293/LER-1999-009-02, :on 990913,manual Scram at 27 Percent Power, Occurred.Caused by Degrading Main Condenser Vacuum. Inspection of Instrument Sensing Lines to E-306B Level Transmitters Was Performed.With +
- 05000461/LER-1987-029, :on 870524,motor Driven Reactor Feed Pump Feedwater Regulating Valve 1FW004 Malfunctioned Causing High Water Level Transient.Caused by Failure of Regulating Valve. Mode Selector Switch Placed in Shutdown +
- 05000498/LER-1988-002, :on 880105,discovered Failure to Perform Local Leakage Rate Testing on Containment Isolation Valves.Caused by Lack of Training Re Required post-maintenance Testing. Valves Retested & Personnel Counseled +
- 05000461/LER-1988-001, :on 880101,two Containment Isolation Valves Closed During Trending of Main Steam Line Causing RWCU Pumps to Trip & Isolation of RWCU Sys.Caused by Random Failure of Temp Module.Temp Module Replaced +
- 05000461/LER-1988-006, :on 880229,Div II Containment Exhaust Process Radiation Monitor Tripped to low-fail Condition.Caused by Personnel Error Due to Inadequate Accessibility & Visibility of Detector.Existing Scaffolding Replaced +
- 05000354/LER-1991-020-01, :on 911207,personnel Received Indication of HPCI Isolation During Steam Line Warmup Following HPCI Outage.Caused by Improper Wiring of Temp Detector.Wiring Corrected & Delta-T Circuits Inspected +
- ML20003F761 +
- 05000247/LER-1917-001, Regarding Manual Reactor Trip Due to Decreasing Steam Generator Levels Caused by Main Boiler Feedwater Pump Turbine Low Pressure Governor Valves Failed Closed +
- 05000454/LER-2001-003-01, Unit, 1,Entry Into Technical Specification Limiting Condition for Operation 3.0.3 Due to a Leak on a Safety Injection Valve Weld Caused by a Pre-Existing Condition, (Supplement One) +
- ML14184B070 +
- 05000316/LER-1986-023, :on 860715 & 18,erroneous Accumulator Level Indication Resulted in Low Accumulator Vol.Caused by Instrumentation Failure.Diagnostic Testing of Instrumentation Planned for Mar 1987 Outage +
- 05000499/LER-1992-004, :on 920428,TS 3.0.3 Entered Due to Containment Isolation Valves Failing to Close.Cause Not Determined.Ts Change Evaluated to Allow Credit for SG Tubes,Tubesheet & Shell as Isolation Barrier +