- ML19339C568 + (ML19339C568)
- 05000265/LER-1980-023-03, /03L-0:on 801010,during LPCI Motor Operated Valve Operability test,MO-2-1001-29A Valve Initially Failed to Open Fully.Caused by Tightly Seated Valve Disc.Torque Switch Limits Adjusted to Allow More Time to Unseat Valve + (ML19339C569)
- ML19339C573 + (ML19339C573)
- ML19339C576 + (ML19339C576)
- 05000327/LER-1980-169-03, /03L-0:on 801014,output Breaker for Vital Inverter 2-III Tripped Rendering Vital Instrument Power Board Inoperable.Caused by Failure of Clock Card RB5.Clock Card Replaced + (ML19339C577)
- 05000327/LER-1980-165, Forwards LER 80-165/03L-0 + (ML19339C578)
- ML19339C579 + (ML19339C579)
- ML19339C580 + (ML19339C580)
- 05000219/LER-1980-046, Forwards LER 80-046/03L-0 + (ML19339C581)
- ML19339C582 + (ML19339C582)
- 05000293/LER-1980-082, Forwards LER 80-082/03L-0 + (ML19339C583)
- ML19339C584 + (ML19339C584)
- 05000327/LER-1980-163, Forwards LER 80-163/03L-0 + (ML19339C585)
- ML19339C586 + (ML19339C586)
- 05000327/LER-1980-165-03, /03L-0:on 801014,essential Raw Cooling Water Monitors O-RE-90-134 & -141 Declared Inoperable.Caused by Auxiliary Feedwater Sys Header Pulsations Causing Pressure Switches to Chatter.Snubbers Added + (ML19339C587)
- 05000219/LER-1980-046-03, /03L-0:on 801017,during Testing of SGTS 2 HEPA Filters,Pressure Drop Across Upstream Filter Exceeded Tech Spec Limit.Caused by Incorrect Replacement of HEPA Filters. Filters Replaced W/Correct Models + (ML19339C588)
- 05000327/LER-1980-163-03, /03L-0:on 801012,both Ventilation Chlorine Detectors O-CLAN-43-205A & B Declared Inoperable Due to Clogged Electrolyte Flow to Sensor.Caused by Clogged Electrolyte in Capillary Tubing & Felt Filter.Parts Cleaned + (ML19339C589)
- 05000293/LER-1980-082-03, /03L-0:on 801008,containment Isolation Valve MO-1001-34B Did Not Close When Actuated by Control Switch. Caused by Failure of Valve Torque Switch.Valve Replaced, Satisfactorily Tested & Returned to Svc + (ML19339C590)
- 05000277/LER-1980-022-03, /03L-0:on 801015,surveillance Testing of DPIS 2-14-43B,core Spray Sparger to Reactor Pressure Vessel delta-pressure Switch,Revealed Setpoint Was Below Tech Spec PSI Limit.Caused by Setpoint Drift.Instrument Recalibr + (ML19339C591)
- 05000271/LER-1980-036, Forwards LER 80-036/03L-0 + (ML19339C592)
- ML19339C593 + (ML19339C593)
- 05000318/LER-1980-047, Forwards LER 80-047/03L-0 + (ML19339C594)
- ML19339C595 + (ML19339C595)
- ML19339C596 + (ML19339C596)
- ML19339C597 + (ML19339C597)
- 05000267/LER-1980-063, Forwards LER 80-063/03L-0 + (ML19339C598)
- ML19339C599 + (ML19339C599)
- BSEP-80-1844, RO 80-83:on 801017,during Routine Insp,Craked Weld Found on HPCI Discharge Line Piping Support.Caused by Lack of Fusion at Weld Point.Support Repaired & Reinforced.Facsimile LER Encl + (ML19339C600)
- 05000271/LER-1980-036-03, /03L-0:on 801017,standby Liquid Control Relief Valve Setpoints Found to Be Above Tech Spec 4.4.A Requirement of 1400 to 1490 Psig.Caused by Setpoint Drift. Relief Valves Adjusted,Bench Tested & Reinstalled + (ML19339C602)
- 05000267/LER-1980-063-03, /03L-0:on 801017,gas Waste Release Routed Through Unsampled Tank.Caused by Nonlicensed Operator Inadvertently Leaving Valve Open + (ML19339C603)
- 05000313/LER-1980-038, Forwards LER 80-038/03L-0 + (ML19339C604)
- ML19339C605 + (ML19339C605)
- 05000344/LER-1980-024, Forwards LER 80-024/03L-0 + (ML19339C606)
- 05000313/LER-1980-038-03, /03L-0:on 801013,during Monthly Surveillance Testing of Number One Diesel Generator,Voltage Regulator Failed to Respond to Higher or Lower Signal.Caused by Internal Mechanical Wear.Regulator Replaced + (ML19339C608)
- 05000344/LER-1980-024-03, /03L-0:on 801011,during Troubleshooting on Steam Generator Sample Valves,Blown Fuse Was Discovered in Automatic Start Circuit of diesel-driven Auxiliary Feedwater Pump.Caused by Ground in Unrelated But Connected Circuit + (ML19339C609)
- 05000306/LER-1980-032, Forwards LER 80-032/03L-0 + (ML19339C610)
- ML19339C611 + (ML19339C611)
- 05000327/LER-1980-167, Forwards LER 80-167/03L-0 + (ML19339C612)
- ML19339C613 + (ML19339C613)
- ML19339C614 + (ML19339C614)
- AECM-80-281, Second Interim Deficiency Rept Re Standby Diesel Generator Jacket Water Cooler Thermostatic Valve Fracture.Cause Not Stated.Magnetic Particle Exam Performed on Remaining Valve. Final Rept Will Be Submitted by 810205 + (ML19339C615)
- 05000339/LER-1980-073, Forwards LER 80-073/03L-0 + (ML19339C616)
- ML19339C617 + (ML19339C617)
- 05000306/LER-1980-032-03, /03L-0:on 801013,during Refueling,Circulating Water Intake Bay Was Drained.Caused by Inoperable Priming Exhauster & Cooling Water Pump 21.Piping Mods Are Being Considered to Allow Maint W/O Effecting Operation + (ML19339C618)
- 05000327/LER-1980-167-03, /03L-0:on 801013,auxiliary Bldg Vent Monitor O-RM-90-110 Declared Inoperable.Caused by Loss of Sampling Pump Due to Circuit Breaker Tripping During Momentary Overload.Circuit Breaker Reset & Monitor Returned to Svc + (ML19339C619)
- 05000325/LER-1980-084, Forwards LER 80-084/03L-0 + (ML19339C620)
- ML19339C621 + (ML19339C621)
- 05000339/LER-1980-073-03, /03L-0:on 801015,comparator Card in Channel II Low Pressure Reactor Trip Circuit Found Inoperative.Caused by Dirty Connector in Card.Card Replaced + (ML19339C622)
- 05000259/LER-1980-080, Forwards LER 80-080/03L-0 + (ML19339C623)
- ML19339C624 + (ML19339C624)
- ML19339C625 + (ML19339C625)