Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML18283A911 + (ML18283A911)
- ML18283A913 + (ML18283A913)
- ML18283A916 + (ML18283A916)
- ML18283A921 + (ML18283A921)
- ML18283A923 + (ML18283A923)
- ML18283A926 + (ML18283A926)
- ML18283A928 + (ML18283A928)
- ML18283A931 + (ML18283A931)
- ML18283A933 + (ML18283A933)
- ML18283A936 + (ML18283A936)
- ML18283A939 + (ML18283A939)
- ML18283A941 + (ML18283A941)
- ML18283A943 + (ML18283A943)
- ML18283A946 + (ML18283A946)
- ML18283A948 + (ML18283A948)
- ML18283A950 + (ML18283A950)
- ML18283A953 + (ML18283A953)
- ML18283A956 + (ML18283A956)
- ML18283A959 + (ML18283A959)
- ML18283A961 + (ML18283A961)
- ML18283A963 + (ML18283A963)
- ML18283A965 + (ML18283A965)
- ML18283A968 + (ML18283A968)
- ML18283A970 + (ML18283A970)
- ML18283A972 + (ML18283A972)
- ML18283A975 + (ML18283A975)
- ML18283A977 + (ML18283A977)
- ML18283A979 + (ML18283A979)
- ML18283A981 + (ML18283A981)
- ML18283A986 + (ML18283A986)
- ML18283A989 + (ML18283A989)
- 05000260/LER-2078-010, For Browns Ferry Nuclear Plant, Unit 2, Relief Valve on Standby Liquid Control Pump B Opened at 900 Psig (Which Is Lower than Designed Setting of 1425 +/- 75 Psig as Designated by Tech Spec 4.4.A.2.A) During Surveillance Testin + (ML18283A990)
- 05000260/LER-2078-008, For Browns Ferry Nuclear Plant, Unit 2, Reactor Building Ventilation Radiation Monitoring Channel Failed During Refueling Outage + (ML18283A991)
- 05000260/LER-2078-006, For Browns Ferry Nuclear Plant, Unit 2, Check Valve 2-73-603 in High-Pressure Coolant Injection System Was Found in Open Position During Maintenance Inspection After Failing Local Leak Rate Test + (ML18283A992)
- ML18283A993 + (ML18283A993)
- 05000260/LER-2078-009, For Browns Ferry Nuclear Plant, Unit 2, Local Leak Rate Tests of All Containment Isolation Valves Where Leak Rate Exceeded Allowable Leak Rate of 60 Percent of La Per 24 Hours or 707.1 Scfh + (ML18283A994)
- 05000260/LER-2078-005, For Browns Ferry Nuclear Plant, Unit 2, Unidentified Coolant Leakage in Drywall Was Found to Be 9.5 Gpm & Exceeded 5 Gpm Limit of Technical Specification 3.6.C.1. During Normal Operation + (ML18283A995)
- 05000260/LER-2078-004, Relief Valve 2-1-5 Opened and Failed to Reseat During Steady State Operation + (ML18283A996)
- 05000260/LER-2078-003, Relief Valve 2-1-41 Opened and Failed to Reseat During Steady State Operation + (ML18283A997)
- ML18283A998 + (ML18283A998)
- 05000260/LER-2078-001, Surveillance Samples Were Taken from Charcoal in Unit 2 Primary Containment Purge System Following Maintenance Outage + (ML18283A999)
- 05000260/LER-2078-002, For Browns Ferry Nuclear Plant, Unit 2, Reactor Pressure Switch PS-68-95 Not Functioning as Required by Tech Spec Table 4.2.B During Normal Operation While Performing Surveillance Instruction ST 4.2.B-7 + (ML18283B000)
- 05000260/LER-2077-012, For Browns Ferry Nuclear Plant, Unit 2, Two Hydraulic Snubbers Were Found Inoperable During the Performance of Surveillance Instruction 4.6.H + (ML18283B001)
- ML18283B002 + (ML18283B002)
- ML18283B003 + (ML18283B003)
- ML18283B004 + (ML18283B004)
- ML18283B006 + (ML18283B006)
- 05000259/LER-2077-011, Reactor Water Column B Reference Leg Was Low, Producing a +20-inch Error in Two Reactor Water low-level Scram Switches During Startup from Cold Shutdown + (ML18283B008)
- 05000260/LER-2077-010, For Browns Ferry Nuclear Plant, Unit 2, Drywell Oxygen Sensor 202M-76-43 Became Erratic During Normal Operation + (ML18283B010)
- 05000260/LER-2077-009, For Browns Ferry Nuclear Plant, Unit 2, Notification by NSSS Vendor, Minimum Critical Power Ratio Limit, as Determined by Analysis of Turbine Trip Without Bypass, Should Be 1.29 for Power Operation with Core Average Exposure + (ML18283B014)
- 05000260/LER-2077-007, For Browns Ferry Nuclear Plant, Unit 2, Limiting Critical Power Ratio-Ratio (Cprrat) Changed from .988 to 1.009 After Local Power Range Monitors (Lprms) Were Calibrated During Steady-State Operation at 97-Percent Power + (ML18283B015)