TXX-6137, Interim Deficiency Rept CP-86-11 Re Linear Indication on Impellers for Component Cooling Water Pumps.Initially Reported on 860623.Vendor Should Complete Repair of Replacement Spare by 870101.Next Rept by 870206 +, TXX-4871, Interim Deficiency Rept CP-86-11 Re Cracks in Bingham-Willamette Impeller Casting of Rotating Element of Component Cooling Water Pumps.Initially Reported on 860224. Impellers Will Be Inspected.Next Rept by 860923 + and TXX-6266, Interim Deficiency Rept CP-86-11 Re Linear Indication on Impellers for Component Cooling Water (CCW) Pumps.Initially Reported on 860623.Insp & Repair of Train a CCW Pump Impeller Completed for Unit 1.Next Rept Expected by 870904 +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
TXX-6266, Interim Deficiency Rept CP-86-11 Re Linear Indication on Impellers for Component Cooling Water (CCW) Pumps.Initially Reported on 860623.Insp & Repair of Train a CCW Pump Impeller Completed for Unit 1.Next Rept Expected by 870904 +, TXX-6266, Interim Deficiency Rept CP-86-11 Re Linear Indication on Impellers for Component Cooling Water (CCW) Pumps.Initially Reported on 860623.Insp & Repair of Train a CCW Pump Impeller Completed for Unit 1.Next Rept Expected by 870904 +, TXX-6266, Interim Deficiency Rept CP-86-11 Re Linear Indication on Impellers for Component Cooling Water (CCW) Pumps.Initially Reported on 860623.Insp & Repair of Train a CCW Pump Impeller Completed for Unit 1.Next Rept Expected by 870904 +, TXX-6266, Interim Deficiency Rept CP-86-11 Re Linear Indication on Impellers for Component Cooling Water (CCW) Pumps.Initially Reported on 860623.Insp & Repair of Train a CCW Pump Impeller Completed for Unit 1.Next Rept Expected by 870904 +, TXX-6266, Interim Deficiency Rept CP-86-11 Re Linear Indication on Impellers for Component Cooling Water (CCW) Pumps.Initially Reported on 860623.Insp & Repair of Train a CCW Pump Impeller Completed for Unit 1.Next Rept Expected by 870904 +, TXX-6266, Interim Deficiency Rept CP-86-11 Re Linear Indication on Impellers for Component Cooling Water (CCW) Pumps.Initially Reported on 860623.Insp & Repair of Train a CCW Pump Impeller Completed for Unit 1.Next Rept Expected by 870904 +, TXX-6266, Interim Deficiency Rept CP-86-11 Re Linear Indication on Impellers for Component Cooling Water (CCW) Pumps.Initially Reported on 860623.Insp & Repair of Train a CCW Pump Impeller Completed for Unit 1.Next Rept Expected by 870904 +, TXX-6266, Interim Deficiency Rept CP-86-11 Re Linear Indication on Impellers for Component Cooling Water (CCW) Pumps.Initially Reported on 860623.Insp & Repair of Train a CCW Pump Impeller Completed for Unit 1.Next Rept Expected by 870904 +, TXX-6266, Interim Deficiency Rept CP-86-11 Re Linear Indication on Impellers for Component Cooling Water (CCW) Pumps.Initially Reported on 860623.Insp & Repair of Train a CCW Pump Impeller Completed for Unit 1.Next Rept Expected by 870904 +, TXX-6266, Interim Deficiency Rept CP-86-11 Re Linear Indication on Impellers for Component Cooling Water (CCW) Pumps.Initially Reported on 860623.Insp & Repair of Train a CCW Pump Impeller Completed for Unit 1.Next Rept Expected by 870904 + and TXX-6266, Interim Deficiency Rept CP-86-11 Re Linear Indication on Impellers for Component Cooling Water (CCW) Pumps.Initially Reported on 860623.Insp & Repair of Train a CCW Pump Impeller Completed for Unit 1.Next Rept Expected by 870904 +
February 6, 1987 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
21:24:34, 6 December 2024 +
1 +
February 6, 1987 +
TXX-6137, Interim Deficiency Rept CP-86-11 Re Linear Indication on Impellers for Component Cooling Water Pumps.Initially Reported on 860623.Vendor Should Complete Repair of Replacement Spare by 870101.Next Rept by 870206 +, TXX-4871, Interim Deficiency Rept CP-86-11 Re Cracks in Bingham-Willamette Impeller Casting of Rotating Element of Component Cooling Water Pumps.Initially Reported on 860224. Impellers Will Be Inspected.Next Rept by 860923 + and TXX-6266, Interim Deficiency Rept CP-86-11 Re Linear Indication on Impellers for Component Cooling Water (CCW) Pumps.Initially Reported on 860623.Insp & Repair of Train a CCW Pump Impeller Completed for Unit 1.Next Rept Expected by 870904 +
Interim Deficiency Rept CP-86-11 Re Linear Indication on Impellers for Component Cooling Water (CCW) Pumps.Initially Reported on 860623.Insp & Repair of Train a CCW Pump Impeller Completed for Unit 1.Next Rept Expected by 870904 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.