The inspectors reviewed a self-revealed no … The inspectors reviewed a self-revealed non-cited violation of 10 CFR 30.41(b)(5) for the failure to transfer byproduct material to an authorized waste disposal facility in accordance with the terms of the facilitys license. Specifically, License Condition No. 21.C of the US Ecology license requires that all radwaste shall be packaged in such a manner that waste containers received at the facility do not show an increase in the external radiation levels as recorded on the manifest, within instrument tolerances. On July 20, 2017, Columbia Generating Station personnel transferred byproduct material to US Ecology for disposal (Shipment 17-51). The disposal facilitys surveys identified that the dose rate on contact with the waste liner was 1100 millirem per hour, whereas the manifest for this shipment recorded a dose rate of 12 millirem per hour. The licensees corrective actions included providing a corrected shipment manifest to US Ecology and proposed enhancements to the Columbia Generating Station procedures for shipping. This issue was documented in the licensees corrective acti on program as Action Request AR 00369215. The failure to transfer byproduct material to a low-level radwaste disposal facility in accordance with the facilitys license was a performance deficiency. The performance deficiency was more than minor because it was associated with the program and process attribute of the Public Radiation Safety Cornerstone and adversely affected the associated cornerstone objective to ensure adequate protection of public health and safety from exposure to radioactive materials released into the public domain as a result of routine civilian nuclear reactor operation. Using NRC Inspection Manual Chapter 0609, Appendix D, Public Radiation Safety Significance Determination Process, the inspectors determined that the finding had very low safety significance (Green) because it was a low-level burial ground nonconformance; however, it was not Class C waste or greater and the waste did conform to the waste characteristics of 10 CFR 61.56. The finding has a cross-cutting aspect in the area of Human Performance, Resources, because licensee leaders failed to ensure that personnel, equipment, procedures, and other resources were available and adequate to support nuclear safety (H.1). adequate to support nuclear safety (H.1).
23:59:59, 30 September 2017 +
23:59:59, 30 September 2017 +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
05000397/FIN-2017010-01 +, 05000397/FIN-2017010-01 +, 05000397/FIN-2017010-01 +, 05000397/FIN-2017010-01 +, 05000397/FIN-2017010-01 +, 05000397/FIN-2017010-01 +, 05000397/FIN-2017010-01 +, 05000397/FIN-2017010-01 +, 05000397/FIN-2017010-01 +, 05000397/FIN-2017010-01 +, 05000397/FIN-2017010-01 +, 05000397/FIN-2017010-01 +, 05000397/FIN-2017010-01 +, 05000397/FIN-2017010-01 +, 05000397/FIN-2017010-01 +, 05000397/FIN-2017010-01 +, 05000397/FIN-2017010-01 +, 05000397/FIN-2017010-01 +, 05000397/FIN-2017010-01 +, 05000397/FIN-2017010-01 +, 05000397/FIN-2017010-01 +, 05000397/FIN-2017010-01 +, 05000397/FIN-2017010-01 +, 05000397/FIN-2017010-01 +, 05000397/FIN-2017010-01 +, 05000397/FIN-2017010-01 +, 05000397/FIN-2017010-01 +, 05000397/FIN-2017010-01 +, 05000397/FIN-2017010-01 +, 05000397/FIN-2017010-01 +...
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
04:25:29, 22 February 2018 +
23:59:59, 30 September 2017 +
Failure to Transfer Byproduct Material to a Disposal Facility in Accordance with the Terms of the Facilitys License +