Browse wiki
Jump to navigation
Jump to search
ML093090682 +
David Bice + and Entergy +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
05000368/LER-2009-003, Steam Generator Tube Exceeding Technical Specification Plugging Criteria Remained in Service During Previous Cycles as a Result of the Failure to Use Proper Independent Verification +, 05000368/LER-2009-003, Steam Generator Tube Exceeding Technical Specification Plugging Criteria Remained in Service During Previous Cycles as a Result of the Failure to Use Proper Independent Verification +, 05000368/LER-2009-003, Steam Generator Tube Exceeding Technical Specification Plugging Criteria Remained in Service During Previous Cycles as a Result of the Failure to Use Proper Independent Verification +, 05000368/LER-2009-003, Steam Generator Tube Exceeding Technical Specification Plugging Criteria Remained in Service During Previous Cycles as a Result of the Failure to Use Proper Independent Verification +, 05000368/LER-2009-003, Steam Generator Tube Exceeding Technical Specification Plugging Criteria Remained in Service During Previous Cycles as a Result of the Failure to Use Proper Independent Verification +, 05000368/LER-2009-003, Steam Generator Tube Exceeding Technical Specification Plugging Criteria Remained in Service During Previous Cycles as a Result of the Failure to Use Proper Independent Verification +, 05000368/LER-2009-003, Steam Generator Tube Exceeding Technical Specification Plugging Criteria Remained in Service During Previous Cycles as a Result of the Failure to Use Proper Independent Verification +, 05000368/LER-2009-003, Steam Generator Tube Exceeding Technical Specification Plugging Criteria Remained in Service During Previous Cycles as a Result of the Failure to Use Proper Independent Verification +, 05000368/LER-2009-003, Steam Generator Tube Exceeding Technical Specification Plugging Criteria Remained in Service During Previous Cycles as a Result of the Failure to Use Proper Independent Verification +, 05000368/LER-2009-003, Steam Generator Tube Exceeding Technical Specification Plugging Criteria Remained in Service During Previous Cycles as a Result of the Failure to Use Proper Independent Verification +, 05000368/LER-2009-003, Steam Generator Tube Exceeding Technical Specification Plugging Criteria Remained in Service During Previous Cycles as a Result of the Failure to Use Proper Independent Verification +, 05000368/LER-2009-003, Steam Generator Tube Exceeding Technical Specification Plugging Criteria Remained in Service During Previous Cycles as a Result of the Failure to Use Proper Independent Verification +, 05000368/LER-2009-003, Steam Generator Tube Exceeding Technical Specification Plugging Criteria Remained in Service During Previous Cycles as a Result of the Failure to Use Proper Independent Verification +, 05000368/LER-2009-003, Steam Generator Tube Exceeding Technical Specification Plugging Criteria Remained in Service During Previous Cycles as a Result of the Failure to Use Proper Independent Verification +, 05000368/LER-2009-003, Steam Generator Tube Exceeding Technical Specification Plugging Criteria Remained in Service During Previous Cycles as a Result of the Failure to Use Proper Independent Verification +, 05000368/LER-2009-003, Steam Generator Tube Exceeding Technical Specification Plugging Criteria Remained in Service During Previous Cycles as a Result of the Failure to Use Proper Independent Verification +, 05000368/LER-2009-003, Steam Generator Tube Exceeding Technical Specification Plugging Criteria Remained in Service During Previous Cycles as a Result of the Failure to Use Proper Independent Verification +, 05000368/LER-2009-003, Steam Generator Tube Exceeding Technical Specification Plugging Criteria Remained in Service During Previous Cycles as a Result of the Failure to Use Proper Independent Verification +, 05000368/LER-2009-003, Steam Generator Tube Exceeding Technical Specification Plugging Criteria Remained in Service During Previous Cycles as a Result of the Failure to Use Proper Independent Verification +, 05000368/LER-2009-003, Steam Generator Tube Exceeding Technical Specification Plugging Criteria Remained in Service During Previous Cycles as a Result of the Failure to Use Proper Independent Verification +, 05000368/LER-2009-003, Steam Generator Tube Exceeding Technical Specification Plugging Criteria Remained in Service During Previous Cycles as a Result of the Failure to Use Proper Independent Verification +, 05000368/LER-2009-003, Steam Generator Tube Exceeding Technical Specification Plugging Criteria Remained in Service During Previous Cycles as a Result of the Failure to Use Proper Independent Verification +, 05000368/LER-2009-003, Steam Generator Tube Exceeding Technical Specification Plugging Criteria Remained in Service During Previous Cycles as a Result of the Failure to Use Proper Independent Verification +, 05000368/LER-2009-003, Steam Generator Tube Exceeding Technical Specification Plugging Criteria Remained in Service During Previous Cycles as a Result of the Failure to Use Proper Independent Verification +, 05000368/LER-2009-003, Steam Generator Tube Exceeding Technical Specification Plugging Criteria Remained in Service During Previous Cycles as a Result of the Failure to Use Proper Independent Verification +, 05000368/LER-2009-003, Steam Generator Tube Exceeding Technical Specification Plugging Criteria Remained in Service During Previous Cycles as a Result of the Failure to Use Proper Independent Verification +, 05000368/LER-2009-003, Steam Generator Tube Exceeding Technical Specification Plugging Criteria Remained in Service During Previous Cycles as a Result of the Failure to Use Proper Independent Verification +, 05000368/LER-2009-003, Steam Generator Tube Exceeding Technical Specification Plugging Criteria Remained in Service During Previous Cycles as a Result of the Failure to Use Proper Independent Verification + and 05000368/LER-2009-003, Steam Generator Tube Exceeding Technical Specification Plugging Criteria Remained in Service During Previous Cycles as a Result of the Failure to Use Proper Independent Verification +
November 5, 2009 +
3 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
13:25:52, 14 January 2025 +
6 +
Request +
10 CFR 50.73(a)(2)(iv)(A), System Actuation +, 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition +, 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor +, 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat +, 10 CFR 50.73(a)(2)(v), Loss of Safety Function +, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability +, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications +, 10 CFR 50.73(a)(2)(i) +, 10 CFR 50.73(a)(2)(x) +, 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded +, 10 CFR 50.73(a)(2)(iii) +, 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown +, 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System +, 10 CFR 50.73(a)(2)(viii)(A) + and 10 CFR 50.73(a)(2)(viii)(B) +
November 5, 2009 +
Washington + and Arkansas +
Steam Generator Tube Exceeding Technical Specification Plugging Criteria Remained in Service During Previous Cycles as a Result of the Failure to Use Proper Independent Verification +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.