Browse wiki

Jump to navigation Jump to search
ML19350E441  +
05000368  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
05000368/LER-1980-086-03, Leak Identified on Sensing Line of Reactor Coolant Pump P Transmitter for 2P32B.Caused by Vibration Induced Fatigue Due to Binding in heli-coil Adjacent to Valve.Line Replaced +, 05000368/LER-1980-086-03, Leak Identified on Sensing Line of Reactor Coolant Pump P Transmitter for 2P32B.Caused by Vibration Induced Fatigue Due to Binding in heli-coil Adjacent to Valve.Line Replaced +, 05000368/LER-1980-086-03, Leak Identified on Sensing Line of Reactor Coolant Pump P Transmitter for 2P32B.Caused by Vibration Induced Fatigue Due to Binding in heli-coil Adjacent to Valve.Line Replaced +, 05000368/LER-1980-086-03, Leak Identified on Sensing Line of Reactor Coolant Pump P Transmitter for 2P32B.Caused by Vibration Induced Fatigue Due to Binding in heli-coil Adjacent to Valve.Line Replaced +, 05000368/LER-1980-086-03, Leak Identified on Sensing Line of Reactor Coolant Pump P Transmitter for 2P32B.Caused by Vibration Induced Fatigue Due to Binding in heli-coil Adjacent to Valve.Line Replaced +, 05000368/LER-1980-086-03, Leak Identified on Sensing Line of Reactor Coolant Pump P Transmitter for 2P32B.Caused by Vibration Induced Fatigue Due to Binding in heli-coil Adjacent to Valve.Line Replaced +, 05000368/LER-1980-086-03, Leak Identified on Sensing Line of Reactor Coolant Pump P Transmitter for 2P32B.Caused by Vibration Induced Fatigue Due to Binding in heli-coil Adjacent to Valve.Line Replaced +, 05000368/LER-1980-086-03, Leak Identified on Sensing Line of Reactor Coolant Pump P Transmitter for 2P32B.Caused by Vibration Induced Fatigue Due to Binding in heli-coil Adjacent to Valve.Line Replaced +, 05000368/LER-1980-086-03, Leak Identified on Sensing Line of Reactor Coolant Pump P Transmitter for 2P32B.Caused by Vibration Induced Fatigue Due to Binding in heli-coil Adjacent to Valve.Line Replaced +, 05000368/LER-1980-086-03, Leak Identified on Sensing Line of Reactor Coolant Pump P Transmitter for 2P32B.Caused by Vibration Induced Fatigue Due to Binding in heli-coil Adjacent to Valve.Line Replaced +, 05000368/LER-1980-086-03, Leak Identified on Sensing Line of Reactor Coolant Pump P Transmitter for 2P32B.Caused by Vibration Induced Fatigue Due to Binding in heli-coil Adjacent to Valve.Line Replaced +, 05000368/LER-1980-086-03, Leak Identified on Sensing Line of Reactor Coolant Pump P Transmitter for 2P32B.Caused by Vibration Induced Fatigue Due to Binding in heli-coil Adjacent to Valve.Line Replaced +  and 05000368/LER-1980-086-03, Leak Identified on Sensing Line of Reactor Coolant Pump P Transmitter for 2P32B.Caused by Vibration Induced Fatigue Due to Binding in heli-coil Adjacent to Valve.Line Replaced +
June 19, 1981  +
1,980  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
07:11:58, 18 September 2025  +
June 19, 1981  +
Leak Identified on Sensing Line of Reactor Coolant Pump P Transmitter for 2P32B.Caused by Vibration Induced Fatigue Due to Binding in heli-coil Adjacent to Valve.Line Replaced  +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.