Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
05000339/LER-1981-017-03, /03L-0:on 810206,reaction Chamber Gas Temp Indicating controller,TIC-5,failed High Offscale Resulting in Automatic Shutdown of Recombiner unit,2-HC-HC-1,on High Temp Interlock.Caused by Loose Plug Connection +, 05000339/LER-1981-017-03, /03L-0:on 810206,reaction Chamber Gas Temp Indicating controller,TIC-5,failed High Offscale Resulting in Automatic Shutdown of Recombiner unit,2-HC-HC-1,on High Temp Interlock.Caused by Loose Plug Connection +, 05000339/LER-1981-017-03, /03L-0:on 810206,reaction Chamber Gas Temp Indicating controller,TIC-5,failed High Offscale Resulting in Automatic Shutdown of Recombiner unit,2-HC-HC-1,on High Temp Interlock.Caused by Loose Plug Connection +, 05000339/LER-1981-017-03, /03L-0:on 810206,reaction Chamber Gas Temp Indicating controller,TIC-5,failed High Offscale Resulting in Automatic Shutdown of Recombiner unit,2-HC-HC-1,on High Temp Interlock.Caused by Loose Plug Connection +, 05000339/LER-1981-017-03, /03L-0:on 810206,reaction Chamber Gas Temp Indicating controller,TIC-5,failed High Offscale Resulting in Automatic Shutdown of Recombiner unit,2-HC-HC-1,on High Temp Interlock.Caused by Loose Plug Connection +, 05000339/LER-1981-017-03, /03L-0:on 810206,reaction Chamber Gas Temp Indicating controller,TIC-5,failed High Offscale Resulting in Automatic Shutdown of Recombiner unit,2-HC-HC-1,on High Temp Interlock.Caused by Loose Plug Connection +, 05000339/LER-1981-017-03, /03L-0:on 810206,reaction Chamber Gas Temp Indicating controller,TIC-5,failed High Offscale Resulting in Automatic Shutdown of Recombiner unit,2-HC-HC-1,on High Temp Interlock.Caused by Loose Plug Connection +, 05000339/LER-1981-017-03, /03L-0:on 810206,reaction Chamber Gas Temp Indicating controller,TIC-5,failed High Offscale Resulting in Automatic Shutdown of Recombiner unit,2-HC-HC-1,on High Temp Interlock.Caused by Loose Plug Connection +, 05000339/LER-1981-017-03, /03L-0:on 810206,reaction Chamber Gas Temp Indicating controller,TIC-5,failed High Offscale Resulting in Automatic Shutdown of Recombiner unit,2-HC-HC-1,on High Temp Interlock.Caused by Loose Plug Connection +, 05000339/LER-1981-017-03, /03L-0:on 810206,reaction Chamber Gas Temp Indicating controller,TIC-5,failed High Offscale Resulting in Automatic Shutdown of Recombiner unit,2-HC-HC-1,on High Temp Interlock.Caused by Loose Plug Connection +, 05000339/LER-1981-017-03, /03L-0:on 810206,reaction Chamber Gas Temp Indicating controller,TIC-5,failed High Offscale Resulting in Automatic Shutdown of Recombiner unit,2-HC-HC-1,on High Temp Interlock.Caused by Loose Plug Connection +, 05000339/LER-1981-017-03, /03L-0:on 810206,reaction Chamber Gas Temp Indicating controller,TIC-5,failed High Offscale Resulting in Automatic Shutdown of Recombiner unit,2-HC-HC-1,on High Temp Interlock.Caused by Loose Plug Connection +  and 05000339/LER-1981-017-03, /03L-0:on 810206,reaction Chamber Gas Temp Indicating controller,TIC-5,failed High Offscale Resulting in Automatic Shutdown of Recombiner unit,2-HC-HC-1,on High Temp Interlock.Caused by Loose Plug Connection +
2.314815e-4 d (0.00556 hours, 3.306878e-5 weeks, 7.61e-6 months)  +
March 5, 1981  +
1,981  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
07:34:00, 23 December 2024  +
March 5, 1981  +
/03L-0:on 810206,reaction Chamber Gas Temp Indicating controller,TIC-5,failed High Offscale Resulting in Automatic Shutdown of Recombiner unit,2-HC-HC-1,on High Temp Interlock.Caused by Loose Plug Connection  +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.