The inspectors identified an Unresolved ItThe inspectors identified an Unresolved Item (URI) associated with the emergency condensate storage tank (ECST) level indication/setpoints and associated operator actions that ensures the auxiliary feedwater (AFW) pumps have an adequate suction source. UFSAR, Section 7.4-2, states that the emergency condensate storage tank (ECST) was designed to supply the initial eight hours of water to the auxiliary feedwater (AFW) pumps during licensing bases events. The inspectors noted that the licensee utilized operator actions to reduce AFW flow during the initial stages of events which is typically accomplished in order to prevent over cooling of the primary RCS during events where maximum AFW is not required. For events where maximum AFW may be required, the licensee developed calculations to ensure that an adequate water supply was maintained. The licensees Calculation ME-0584, Maximum AFW Pump Flow and NPSH Analysis, (dated 11/04/1999) determined that AFW flow reduction was required within the initial 30 minutes of an event to ensure that the pumps had sufficient net positive suction head. The inspectors determined, in some cases, that operator actions would be required prior to the receipt of the ECST tank level alarm that was described UFSAR Section 10.4.3.3, which stated that the ECST had redundant ECST safety-level alarms (1/2-CN-LI-200A and -200B) to alert operators that sufficient inventory remained for 20 minutes of pump operation at the highest-volume flow rates. Additionally, the inspectors noted that a Virginia Electric Power Company letter, dated December 22, 1999, stated that Technical Specifications ensure that the level maintained in the ECST is adequate to mitigate the accident without operator action during a design basis accident. Therefore, the indication of ECST level is not required as a Type A variable. Indication of ECST level remains a Type D, Category 1 variable... This issue is unresolved pending the NRCs review of applicable licensing requirements, calculations, and operating procedures to assess the adequacy of the ECST level indication/setpoints and associated operator actions to ensure that the AFW pumps have an adequate suction source as described by their licensing design basis. This issue is identified as URI 05000338 & 05000339/2015008-02, ECST Level Indication/Setpoints and Associated Operator Action that Ensures the Auxiliary Feedwater Pumps have an Adequate Suction Source.edwater Pumps have an Adequate Suction Source.  
23:59:59, 31 December 2015  +
00338  +, 05000338  +  and 05000339  +
23:59:59, 31 December 2015  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:54:10, 21 February 2018  +
23:59:59, 31 December 2015  +
ECST Level Indication/Setpoints and Associated Operator Action that Ensures the Auxiliary Feedwater Pumps have an Adequate Suction Source  +