Browse wiki

Jump to navigation Jump to search
10 CFR 50, Appendix B, Criterion V, Instru10 CFR 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, states, in part, that activities affecting quality shall be prescribed by documented procedures. Contrary to this, the licensee identified that they failed to adequately prescribe procedure, VPAP-0905, Insulation Control Program, Revision 5, for adequate control of insulation work to avoid critical components. Consequently, the 2J EDG was rendered inoperable and unavailable when the governor drain petcock was inadvertently opened during replacement of insulation on the exhaust manifold. This issue is in the licensees CAP as CR403015, 2-EE-EG-2J governor oil inadvertently drained during insulation work.dvertently drained during insulation work.  +
23:59:59, 31 December 2010  +
05000338  +  and 05000339  +
23:59:59, 31 December 2010  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
15:41:03, 30 May 2018  +
23:59:59, 31 December 2010  +
Licensee-Identified Violation  +