Browse wiki
Jump to navigation
Jump to search
ML22081A025 +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
05000336/LER-2022-001, Structural Integrity of Reactor Building Component Cooling Water Cracked Threaded Fitting Could Not Be Established Resulting in System Inoperable Longer than Allowed by Technical Specifications +, 05000336/LER-2022-001, Structural Integrity of Reactor Building Component Cooling Water Cracked Threaded Fitting Could Not Be Established Resulting in System Inoperable Longer than Allowed by Technical Specifications +, 05000336/LER-2022-001, Structural Integrity of Reactor Building Component Cooling Water Cracked Threaded Fitting Could Not Be Established Resulting in System Inoperable Longer than Allowed by Technical Specifications +, 05000336/LER-2022-001, Structural Integrity of Reactor Building Component Cooling Water Cracked Threaded Fitting Could Not Be Established Resulting in System Inoperable Longer than Allowed by Technical Specifications +, 05000336/LER-2022-001, Structural Integrity of Reactor Building Component Cooling Water Cracked Threaded Fitting Could Not Be Established Resulting in System Inoperable Longer than Allowed by Technical Specifications +, 05000336/LER-2022-001, Structural Integrity of Reactor Building Component Cooling Water Cracked Threaded Fitting Could Not Be Established Resulting in System Inoperable Longer than Allowed by Technical Specifications +, 05000336/LER-2022-001, Structural Integrity of Reactor Building Component Cooling Water Cracked Threaded Fitting Could Not Be Established Resulting in System Inoperable Longer than Allowed by Technical Specifications +, 05000336/LER-2022-001, Structural Integrity of Reactor Building Component Cooling Water Cracked Threaded Fitting Could Not Be Established Resulting in System Inoperable Longer than Allowed by Technical Specifications +, 05000336/LER-2022-001, Structural Integrity of Reactor Building Component Cooling Water Cracked Threaded Fitting Could Not Be Established Resulting in System Inoperable Longer than Allowed by Technical Specifications +, 05000336/LER-2022-001, Structural Integrity of Reactor Building Component Cooling Water Cracked Threaded Fitting Could Not Be Established Resulting in System Inoperable Longer than Allowed by Technical Specifications +, 05000336/LER-2022-001, Structural Integrity of Reactor Building Component Cooling Water Cracked Threaded Fitting Could Not Be Established Resulting in System Inoperable Longer than Allowed by Technical Specifications +, 05000336/LER-2022-001, Structural Integrity of Reactor Building Component Cooling Water Cracked Threaded Fitting Could Not Be Established Resulting in System Inoperable Longer than Allowed by Technical Specifications +, 05000336/LER-2022-001, Structural Integrity of Reactor Building Component Cooling Water Cracked Threaded Fitting Could Not Be Established Resulting in System Inoperable Longer than Allowed by Technical Specifications +, 05000336/LER-2022-001, Structural Integrity of Reactor Building Component Cooling Water Cracked Threaded Fitting Could Not Be Established Resulting in System Inoperable Longer than Allowed by Technical Specifications + and 05000336/LER-2022-001, Structural Integrity of Reactor Building Component Cooling Water Cracked Threaded Fitting Could Not Be Established Resulting in System Inoperable Longer than Allowed by Technical Specifications +
8.333333e-4 d (0.02 hours, 1.190476e-4 weeks, 2.7396e-5 months) +, 0.022 d (0.528 hours, 0.00314 weeks, 7.2295e-4 months) +, 0.0162 d (0.389 hours, 0.00231 weeks, 5.327e-4 months) +, 0.0189 d (0.453 hours, 0.0027 weeks, 6.20976e-4 months) +, 0.00382 d (0.0917 hours, 5.456349e-4 weeks, 1.25565e-4 months) + and 2.777778e-4 d (0.00667 hours, 3.968254e-5 weeks, 9.132e-6 months) +
March 18, 2022 +
1 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
22:42:33, 27 November 2024 +
6 +
Request +
March 18, 2022 +
Connecticut + and Washington +
Structural Integrity of Reactor Building Component Cooling Water Cracked Threaded Fitting Could Not Be Established Resulting in System Inoperable Longer than Allowed by Technical Specifications +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.