Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
05000335/LER-1995-010-01, :on 951116,manual Reactor Trip Occurred Due to Degraded 24 Volt Dc Power Supply to 1B SG Main Feedwater Controller.Tested & Replaced Power Supply for 1B Feedwater Controller.W/Undated Ltr +, 05000335/LER-1995-010-01, :on 951116,manual Reactor Trip Occurred Due to Degraded 24 Volt Dc Power Supply to 1B SG Main Feedwater Controller.Tested & Replaced Power Supply for 1B Feedwater Controller.W/Undated Ltr +, 05000335/LER-1995-010-01, :on 951116,manual Reactor Trip Occurred Due to Degraded 24 Volt Dc Power Supply to 1B SG Main Feedwater Controller.Tested & Replaced Power Supply for 1B Feedwater Controller.W/Undated Ltr +, 05000335/LER-1995-010-01, :on 951116,manual Reactor Trip Occurred Due to Degraded 24 Volt Dc Power Supply to 1B SG Main Feedwater Controller.Tested & Replaced Power Supply for 1B Feedwater Controller.W/Undated Ltr +, 05000335/LER-1995-010-01, :on 951116,manual Reactor Trip Occurred Due to Degraded 24 Volt Dc Power Supply to 1B SG Main Feedwater Controller.Tested & Replaced Power Supply for 1B Feedwater Controller.W/Undated Ltr +, 05000335/LER-1995-010-01, :on 951116,manual Reactor Trip Occurred Due to Degraded 24 Volt Dc Power Supply to 1B SG Main Feedwater Controller.Tested & Replaced Power Supply for 1B Feedwater Controller.W/Undated Ltr +, 05000335/LER-1995-010-01, :on 951116,manual Reactor Trip Occurred Due to Degraded 24 Volt Dc Power Supply to 1B SG Main Feedwater Controller.Tested & Replaced Power Supply for 1B Feedwater Controller.W/Undated Ltr +, 05000335/LER-1995-010-01, :on 951116,manual Reactor Trip Occurred Due to Degraded 24 Volt Dc Power Supply to 1B SG Main Feedwater Controller.Tested & Replaced Power Supply for 1B Feedwater Controller.W/Undated Ltr +, 05000335/LER-1995-010-01, :on 951116,manual Reactor Trip Occurred Due to Degraded 24 Volt Dc Power Supply to 1B SG Main Feedwater Controller.Tested & Replaced Power Supply for 1B Feedwater Controller.W/Undated Ltr +, 05000335/LER-1995-010-01, :on 951116,manual Reactor Trip Occurred Due to Degraded 24 Volt Dc Power Supply to 1B SG Main Feedwater Controller.Tested & Replaced Power Supply for 1B Feedwater Controller.W/Undated Ltr +, 05000335/LER-1995-010-01, :on 951116,manual Reactor Trip Occurred Due to Degraded 24 Volt Dc Power Supply to 1B SG Main Feedwater Controller.Tested & Replaced Power Supply for 1B Feedwater Controller.W/Undated Ltr +, 05000335/LER-1995-010-01, :on 951116,manual Reactor Trip Occurred Due to Degraded 24 Volt Dc Power Supply to 1B SG Main Feedwater Controller.Tested & Replaced Power Supply for 1B Feedwater Controller.W/Undated Ltr +, 05000335/LER-1995-010-01, :on 951116,manual Reactor Trip Occurred Due to Degraded 24 Volt Dc Power Supply to 1B SG Main Feedwater Controller.Tested & Replaced Power Supply for 1B Feedwater Controller.W/Undated Ltr +, 05000335/LER-1995-010-01, :on 951116,manual Reactor Trip Occurred Due to Degraded 24 Volt Dc Power Supply to 1B SG Main Feedwater Controller.Tested & Replaced Power Supply for 1B Feedwater Controller.W/Undated Ltr +, 05000335/LER-1995-010-01, :on 951116,manual Reactor Trip Occurred Due to Degraded 24 Volt Dc Power Supply to 1B SG Main Feedwater Controller.Tested & Replaced Power Supply for 1B Feedwater Controller.W/Undated Ltr +, 05000335/LER-1995-010-01, :on 951116,manual Reactor Trip Occurred Due to Degraded 24 Volt Dc Power Supply to 1B SG Main Feedwater Controller.Tested & Replaced Power Supply for 1B Feedwater Controller.W/Undated Ltr +, 05000335/LER-1995-010-01, :on 951116,manual Reactor Trip Occurred Due to Degraded 24 Volt Dc Power Supply to 1B SG Main Feedwater Controller.Tested & Replaced Power Supply for 1B Feedwater Controller.W/Undated Ltr +, 05000335/LER-1995-010-01, :on 951116,manual Reactor Trip Occurred Due to Degraded 24 Volt Dc Power Supply to 1B SG Main Feedwater Controller.Tested & Replaced Power Supply for 1B Feedwater Controller.W/Undated Ltr +, 05000335/LER-1995-010-01, :on 951116,manual Reactor Trip Occurred Due to Degraded 24 Volt Dc Power Supply to 1B SG Main Feedwater Controller.Tested & Replaced Power Supply for 1B Feedwater Controller.W/Undated Ltr +, 05000335/LER-1995-010-01, :on 951116,manual Reactor Trip Occurred Due to Degraded 24 Volt Dc Power Supply to 1B SG Main Feedwater Controller.Tested & Replaced Power Supply for 1B Feedwater Controller.W/Undated Ltr + and 05000335/LER-1995-010-01, :on 951116,manual Reactor Trip Occurred Due to Degraded 24 Volt Dc Power Supply to 1B SG Main Feedwater Controller.Tested & Replaced Power Supply for 1B Feedwater Controller.W/Undated Ltr +
December 14, 1995 +
10 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
18:32:52, 8 January 2025 +
10 +
10 CFR 50.73(a)(2)(v), Loss of Safety Function +, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability +, 10 CFR 50.73(a)(2)(iv), System Actuation +, 10 CFR 50.73(a)(2)(i) +, 10 CFR 50.73(a)(2)(x) +, 10 CFR 50.73(a)(2)(iii) +, 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition + and 10 CFR 50.73(a)(2)(viii) +
December 14, 1995 +
Florida + and Washington +
:on 951116,manual Reactor Trip Occurred Due to Degraded 24 Volt Dc Power Supply to 1B SG Main Feedwater Controller.Tested & Replaced Power Supply for 1B Feedwater Controller.W/Undated Ltr
+
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.