Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
05000331/LER-1982-076-03, /03L-0:on 821108,during Shutdown Surveillance Testing,Drywell Pressure Switch PS-4310C Tripped at 2.2 Psig Instead of Tech Spec Setpoint of 1.5 Plus/Minus 0.5 Psig Increasing.Caused by Setpoint Drift.Switch Recalibr +, 05000331/LER-1982-076-03, /03L-0:on 821108,during Shutdown Surveillance Testing,Drywell Pressure Switch PS-4310C Tripped at 2.2 Psig Instead of Tech Spec Setpoint of 1.5 Plus/Minus 0.5 Psig Increasing.Caused by Setpoint Drift.Switch Recalibr +, 05000331/LER-1982-076-03, /03L-0:on 821108,during Shutdown Surveillance Testing,Drywell Pressure Switch PS-4310C Tripped at 2.2 Psig Instead of Tech Spec Setpoint of 1.5 Plus/Minus 0.5 Psig Increasing.Caused by Setpoint Drift.Switch Recalibr +, 05000331/LER-1982-076-03, /03L-0:on 821108,during Shutdown Surveillance Testing,Drywell Pressure Switch PS-4310C Tripped at 2.2 Psig Instead of Tech Spec Setpoint of 1.5 Plus/Minus 0.5 Psig Increasing.Caused by Setpoint Drift.Switch Recalibr +, 05000331/LER-1982-076-03, /03L-0:on 821108,during Shutdown Surveillance Testing,Drywell Pressure Switch PS-4310C Tripped at 2.2 Psig Instead of Tech Spec Setpoint of 1.5 Plus/Minus 0.5 Psig Increasing.Caused by Setpoint Drift.Switch Recalibr +, 05000331/LER-1982-076-03, /03L-0:on 821108,during Shutdown Surveillance Testing,Drywell Pressure Switch PS-4310C Tripped at 2.2 Psig Instead of Tech Spec Setpoint of 1.5 Plus/Minus 0.5 Psig Increasing.Caused by Setpoint Drift.Switch Recalibr +, 05000331/LER-1982-076-03, /03L-0:on 821108,during Shutdown Surveillance Testing,Drywell Pressure Switch PS-4310C Tripped at 2.2 Psig Instead of Tech Spec Setpoint of 1.5 Plus/Minus 0.5 Psig Increasing.Caused by Setpoint Drift.Switch Recalibr +, 05000331/LER-1982-076-03, /03L-0:on 821108,during Shutdown Surveillance Testing,Drywell Pressure Switch PS-4310C Tripped at 2.2 Psig Instead of Tech Spec Setpoint of 1.5 Plus/Minus 0.5 Psig Increasing.Caused by Setpoint Drift.Switch Recalibr +, 05000331/LER-1982-076-03, /03L-0:on 821108,during Shutdown Surveillance Testing,Drywell Pressure Switch PS-4310C Tripped at 2.2 Psig Instead of Tech Spec Setpoint of 1.5 Plus/Minus 0.5 Psig Increasing.Caused by Setpoint Drift.Switch Recalibr +, 05000331/LER-1982-076-03, /03L-0:on 821108,during Shutdown Surveillance Testing,Drywell Pressure Switch PS-4310C Tripped at 2.2 Psig Instead of Tech Spec Setpoint of 1.5 Plus/Minus 0.5 Psig Increasing.Caused by Setpoint Drift.Switch Recalibr +, 05000331/LER-1982-076-03, /03L-0:on 821108,during Shutdown Surveillance Testing,Drywell Pressure Switch PS-4310C Tripped at 2.2 Psig Instead of Tech Spec Setpoint of 1.5 Plus/Minus 0.5 Psig Increasing.Caused by Setpoint Drift.Switch Recalibr +, 05000331/LER-1982-076-03, /03L-0:on 821108,during Shutdown Surveillance Testing,Drywell Pressure Switch PS-4310C Tripped at 2.2 Psig Instead of Tech Spec Setpoint of 1.5 Plus/Minus 0.5 Psig Increasing.Caused by Setpoint Drift.Switch Recalibr +, 05000331/LER-1982-076-03, /03L-0:on 821108,during Shutdown Surveillance Testing,Drywell Pressure Switch PS-4310C Tripped at 2.2 Psig Instead of Tech Spec Setpoint of 1.5 Plus/Minus 0.5 Psig Increasing.Caused by Setpoint Drift.Switch Recalibr + and 05000331/LER-1982-076-03, /03L-0:on 821108,during Shutdown Surveillance Testing,Drywell Pressure Switch PS-4310C Tripped at 2.2 Psig Instead of Tech Spec Setpoint of 1.5 Plus/Minus 0.5 Psig Increasing.Caused by Setpoint Drift.Switch Recalibr +
December 3, 1982 +
76 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
14:58:51, 16 December 2024 +
1 +
December 3, 1982 +
/03L-0:on 821108,during Shutdown Surveillance Testing,Drywell Pressure Switch PS-4310C Tripped at 2.2 Psig Instead of Tech Spec Setpoint of 1.5 Plus/Minus 0.5 Psig Increasing.Caused by Setpoint Drift.Switch Recalibr +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.