W3F1-2014-0041, 180 Day Steam Generator Tube Inspection Report for the 19TH Refueling Outage | 6 November 2014 | Entergy Jarrell J | 180 Day Steam Generator Tube Inspection Report for the 19TH Refueling Outage | Request |
ML15082A297 | 3 April 2015 | Michael Orenak Plant Licensing Branch IV | Request for Additional Information Regarding the Spring 2014 Steam Generator Tube Inspections | RAI |
ML15147A087 | 21 May 2015 | Entergy Jarrell J | Response to Request for Additional Information Regarding the 180-Day Steam Generator Tube Inspection Report for the 19th Refueling Outage | Response to RAI |
ML15153A233 | 15 June 2015 | Michael Orenak Plant Licensing Branch IV | Request for Withholding Information from Public Disclose - 5/20/15 Affidavit Executed by J. Gresham, Westinghouse, the 180-Day Steam Generator the 180-Day Steam Generator Report | Withholding Request Acceptance |
ML15181A097 | 7 July 2015 | Michael Orenak Plant Licensing Branch IV | Review of Steam Generator Tube Inspection Report for Refueling Outage 19 | Approval |