Semantic search
Jump to navigation
Jump to search
Issue date | From | Title | Project stage | |
---|---|---|---|---|
CP-201100356, Relief Request A-1 for Unit 1 Inservice Inspection for Application of an Alternative to the ASME Boiler and Pressure Vessel Code Section XI Examination Requirements for Class 1 and 2 Piping Welds (Third Interval....) | 2 August 2011 | Luminant Madden F | Relief Request A-1 for Unit 1 Inservice Inspection for Application of an Alternative to the ASME Boiler and Pressure Vessel Code Section XI Examination Requirements for Class 1 and 2 Piping Welds (Third Interval....) | Request |
ML112500329 | 7 September 2011 | Balwant Singal Plant Licensing Branch IV | Acceptance Review Email, Relief Request A-1 for Approval of Risk-Informed Alternative to ASME Code, Section XI for Class 1 and 2 Piping Welds, Third 10-Year Inservice Inspection Interval | Acceptance Review |
ML120250543 | 25 January 2012 | Balwant Singal Plant Licensing Branch IV | Email, Request for Additional Information Relief Request A-1 | RAI |
ML120270364 | 27 January 2012 | Balwant Singal Plant Licensing Branch IV | Correction to Email, Request for Additional Information, Relief Request A-1, Risk-Informed Alternative to Code Exam Requirements for Class 1 and 2 Piping Welds, Second 10-Year Inservice Inspection Interval | RAI |
CP-201200097, Response to Request for Additional Information for Relief Request No. A-1 | 21 February 2012 | Luminant Madden F | Response to Request for Additional Information for Relief Request No. A-1 | Response to RAI |
CP-201200157, Response to Request for Additional Information for Relief Request No. A-1 | 8 March 2012 | Luminant Flores R Madden F | Response to Request for Additional Information for Relief Request No. A-1 | Response to RAI |
CP-201200488, Response to Request for Additional Information for Relief Request No. A-I | 6 June 2012 | Luminant Flores R Madden F | Response to Request for Additional Information for Relief Request No. A-I | Response to RAI |
ML12194A250 | 14 August 2012 | Division of Operating Reactor Licensing Markley M | Relief Request A-1 for Approval of Risk-Informed Alternative to ASME Code, Section XI for Class 1 and 2 Piping Welds, Third 10-Year Inservice Inspection Interval | Other |