ML20059C96722 December 1993Callan L
Office of Nuclear Reactor Regulation
Forwards Request for Addl Info Re GL 92-08, Thermo-Lag 330-1 Fire Barriers, Per 10CFR50.54(f)RAI
RBG-41123, Forwards Response to NRC follow-up to RAI Re GL 92-08, Requesting Addl Info for Section Ii.B, Important Barrier Parameters & Section Iii.B, Thermo-Lag Fire Barriers Outside Scope of NUMARC Program21 December 1994Entergy
INC.
Fiscaro J
Forwards Response to NRC follow-up to RAI Re GL 92-08, Requesting Addl Info for Section Ii.B, Important Barrier Parameters & Section Iii.B, Thermo-Lag Fire Barriers Outside Scope of NUMARC ProgramOther
RBG-41346, Forwards Response to follow-up Request for Addl Info Re GL 92-0828 March 1995Entergy
INC.
James Fisicaro
Forwards Response to follow-up Request for Addl Info Re GL 92-08Request
RBG-42029, Forwards Destructive Exam Sampling Plan & Summary Results,As Supplement to 950328 Response to follow-up to RAI Re Generic Ltr 92-08 Issued Per 10CFR50.54(f) on 94122826 October 1995Entergy
INC.
James Fisicaro
Forwards Destructive Exam Sampling Plan & Summary Results,As Supplement to 950328 Response to follow-up to RAI Re Generic Ltr 92-08 Issued Per 10CFR50.54(f) on 941228Supplement
RBG-42159, Forwards Response to 950925 RAI Re GL 92-08, Thermo-Lag 330-1 Fire Barriers, Including Response to GL 92-08 Reporting Requirement 2(c) from & Calculations Which Will Be Used to Detemine Ampacity Derating Parameters9 November 1995Entergy
INC.
James Fisicaro
Forwards Response to 950925 RAI Re GL 92-08, Thermo-Lag 330-1 Fire Barriers, Including Response to GL 92-08 Reporting Requirement 2(c) from & Calculations Which Will Be Used to Detemine Ampacity Derating ParametersOther
RBG-43067, Provides Supplemental Response to Request for Addl Info Re Ampacity Derating,Per GL 92-08, Thermo-Lag 330-1 Fire Barriers. Calculation Encl28 June 1996Entergy
INC.
King R
Provides Supplemental Response to Request for Addl Info Re Ampacity Derating,Per GL 92-08, Thermo-Lag 330-1 Fire Barriers. Calculation EnclSupplement
ML20129A05116 October 1996NRC (Affiliation Not Assigned)
Wigginton D
Requests Additional Info Re Ampacity Derating Methodology W/Respect to Thermo-Lag Fire Barriers & Forwards Ltr ReptOther
RBG-43571, Provides Responses to 961016 RAI Re Ampacity Derating Including Supporting Draft Calculations G13.18.14.0-178,Rev 0, Ampacity Derating Factors for Thermo-Lag 330-1 & E-128, Rev 1, Ampacity Verification....Fire Protection Barrier19 December 1996Entergy
INC.
King R
Provides Responses to 961016 RAI Re Ampacity Derating Including Supporting Draft Calculations G13.18.14.0-178,Rev 0, Ampacity Derating Factors for Thermo-Lag 330-1 & E-128, Rev 1, Ampacity Verification....Fire Protection BarrierDraft Other
ML20141H36821 May 1997NRC (Affiliation Not Assigned)
Wigginton D
Discusses Entergy Operations,Inc 930414,940209,1221,950328, 1026,1109,960628 & 1219 Ltrs in Response to GL 92-08,in Regard to Thermo-Lag 330-1 Fire Barriers Installed at River Bend Station,Unit 1Other
RBG-44230, Forwards Response to 970512 RAI Re Thermo-Lag Related Ampacity Derating Issues.Encl Also Contains Supporting Calculations,Rev 1 to G13.18.14.0-178 & Rev 1 to E-2183 October 1997Entergy
INC.
King R
Forwards Response to 970512 RAI Re Thermo-Lag Related Ampacity Derating Issues.Encl Also Contains Supporting Calculations,Rev 1 to G13.18.14.0-178 & Rev 1 to E-218Other
RBG-44325, Notifies That Actions Associated W/Resolution of Thermo-Lag Issues at Plant Completed,Per GL 92-08.First Phase Completed by Development of Revised Safe Shutdown Analysis25 November 1997Entergy
INC.
King R
Notifies That Actions Associated W/Resolution of Thermo-Lag Issues at Plant Completed,Per GL 92-08.First Phase Completed by Development of Revised Safe Shutdown AnalysisOther