05000298/LER-1982-014, Amended LER 82-014/03X-1:on 820607,rejectable Indications Found in Heat Affected Zones of Welds BJ-13,BJ-15,BJ-20 & BJ-23.Caused by Improper Fabrication Techniques.Affected Piping & Fittings Replaced3 February 1983Nebraska Public Power District
Lessor L
Freborg S
Amended LER 82-014/03X-1:on 820607,rejectable Indications Found in Heat Affected Zones of Welds BJ-13,BJ-15,BJ-20 & BJ-23.Caused by Improper Fabrication Techniques.Affected Piping & Fittings ReplacedOther
A830019, Forwards Info Re Intergranular Stress Corrosion Cracking Observed in Core Spray & Reactor Water Cleanup Sys,Per 830822 Request.Weld Overlay Repairs Meet Safety Margins of App X to Section IX of ASME Code23 August 1983Nebraska Public Power District
Pilant J
Forwards Info Re Intergranular Stress Corrosion Cracking Observed in Core Spray & Reactor Water Cleanup Sys,Per 830822 Request.Weld Overlay Repairs Meet Safety Margins of App X to Section IX of ASME CodeOther
ML20080D82325 August 1983Nebraska Public Power DistrictRevised Tech Specs Re Limiting Conditions for Operation & Surveillance Requirements of Coolant Leakage During Cycle 9 OperationOther
ML20080D80725 August 1983Nebraska Public Power District
Pilant J