Semantic search

Jump to navigation Jump to search
 Issue dateFromTitleProject stage
RS-16-191, License Amendment Request to Revise Technical Specifications 5.5.13, Primary Containment Leakage Rate Testing Program, for Permanent Extension of Type a and Type C Leak Rate Test Frequencies26 October 2016Exelon
David Gullott
License Amendment Request to Revise Technical Specifications 5.5.13, Primary Containment Leakage Rate Testing Program, for Permanent Extension of Type a and Type C Leak Rate Test FrequenciesRequest
ML16350A07415 December 2016Bhalchandra Vaidya
Plant Licensing Branch III
Acceptance for Review of Application Concerning Extension of Type a and Type C Leak Rate Test FrequenciesAcceptance Review
RS-17-024, Supplement to License Amendment Request for Permanent Extension of Type a and Type C Leak Rate Test Frequencies Regarding Hardened Containment Vent System Modifications and Installation of Primary Containment Isolation Valves16 February 2017Exelon
David Gullott
Supplement to License Amendment Request for Permanent Extension of Type a and Type C Leak Rate Test Frequencies Regarding Hardened Containment Vent System Modifications and Installation of Primary Containment Isolation ValvesSupplement
ML17151A3825 June 2017Bhalchandra Vaidya
Plant Licensing Branch III
Request for Additional Information Regarding License Amendment Request for Extension of Type a and Type C Leak Rate Test FrequenciesRAI
ML17164A11515 June 2017Bhalchandra Vaidya
Plant Licensing Branch III
Request for Additional Information Regarding License Amendment Request for Extension of Type a and Type C Leak Rate Test FrequenciesRAI
RS-17-098, Response to Request for Additional Information Regarding License Amendment Request for Extension of Type a and Type C Containment Leak Rate Test Intervals (Sbpb Branch)17 July 2017Exelon
David Gullott
Response to Request for Additional Information Regarding License Amendment Request for Extension of Type a and Type C Containment Leak Rate Test Intervals (Sbpb Branch)Response to RAI
RS-17-099, Response to Request for Additional Information Regarding LaSalle County Station License Amendment Request for Extension of Type a and Type C Containment Leak Rate Test Intervals (PRA Branch)8 August 2017Exelon
David Gullott
Response to Request for Additional Information Regarding LaSalle County Station License Amendment Request for Extension of Type a and Type C Containment Leak Rate Test Intervals (PRA Branch)Response to RAI
RS-17-131, Supplemental Information Regarding LaSalle County Station License Amendment Request for Extension of Type a and Type C Containment Leak Rate Test Intervals27 September 2017Exelon
David Gullott
Supplemental Information Regarding LaSalle County Station License Amendment Request for Extension of Type a and Type C Containment Leak Rate Test IntervalsSupplement
RS-17-133, Additional Supplemental Information Regarding LaSalle County Station License Amendment Request for Extension of Type a and Type C Containment Leak Rate Test Intervals3 October 2017Exelon
David Gullott
Additional Supplemental Information Regarding LaSalle County Station License Amendment Request for Extension of Type a and Type C Containment Leak Rate Test IntervalsSupplement
RS-17-157, Supplemental Information Regarding the Third Interval Containment Inservice Inspection (Cisi) Schedule for LaSalle County Station License Amendment Request for Extension of Type a and Type C Containment Leak Rate Test Intervals8 November 2017Exelon
Simpson P
Supplemental Information Regarding the Third Interval Containment Inservice Inspection (Cisi) Schedule for LaSalle County Station License Amendment Request for Extension of Type a and Type C Containment Leak Rate Test IntervalsSupplement
ML17283A08516 November 2017Bhalchandra Vaidya
Plant Licensing Branch III
Issuance of Amendment Nos. 226 and 212 - Revise Technical Specification 5.5.13, Primary Containment Leakage Rate Testing Program, for Permanent Extension of Leak Rate Test Frequencies (CAC MF8700 and MF8701; L-2016-LLA-0021)Approval