Semantic search
Jump to navigation
Jump to search
Issue date | From | Title | Site | Project stage | |
---|---|---|---|---|---|
LR-N16-0002, License Amendment Request to Amend Technical Specifications (TS) to Delete Action Statement 3.4.2.1.b Associated with Stuck Open Safety/Relief Valves (Srvs) | 11 May 2016 | PSEG Davison P | License Amendment Request to Amend Technical Specifications (TS) to Delete Action Statement 3.4.2.1.b Associated with Stuck Open Safety/Relief Valves (Srvs) | Hope Creek | Request |
ML16167A532 | 15 June 2016 | Thomas Wengert Plant Licensing Branch I | NRR E-mail Capture - Hope Creek - Acceptance Review of LAR to Amend TSs to Delete Action Statement 3.4.2.1.b Associated with Stuck Open SRVs | Hope Creek | Acceptance Review |
ML16271A205 | 2 November 2016 | Carleen Parker Plant Licensing Branch I | Request for Additional Information Regarding Request to Delete Technical Specifications Action Statement 3.4.2.1.b Associated with Stuck Open Safety/Relief Valves | Hope Creek | RAI |
LR-N16-0192, Response to Request for Additional Information Stuck Open Safety/Relief Valves | 13 December 2016 | PSEG Carr E | Response to Request for Additional Information Stuck Open Safety/Relief Valves | Hope Creek | Response to RAI |