NL-15-2121, Third Six-Month Status Report of the Implementation of the Commission Order with Regard to Requirements for Reliable Hardened Containment Vents (EA-13-109)23 December 2015Southern Nuclear
Pierce C
Third Six-Month Status Report of the Implementation of the Commission Order with Regard to Requirements for Reliable Hardened Containment Vents (EA-13-109)Other
ML16099A2602 August 2016Jessie Quichocho
Containment and Balance of Plant Branch
Interim Staff Evaluation for Phase 2 of NRC Order EA-13-109Other
NL-17-0778, Sixth Six-Month Status Report of the Implementation of the Commission Order with Regard to Requirements for Reliable Hardened Containment Vents (EA-13-109)12 June 2017Southern Nuclear
Hutto J
Sixth Six-Month Status Report of the Implementation of the Commission Order with Regard to Requirements for Reliable Hardened Containment Vents (EA-13-109)Other
ML17254A04219 September 2017Rajender Auluck
Japan Lessons-Learned Division
Report for the Audits of Licensee Responses of Order EA-13-109 to Modify Licenses with Regard to Reliable Hardened Containment Vents Capable of Operation Under Severe Accident Conditions (CAC Nos. MF4479 andOther
NL-18-0200, Unit 1, Completion of Required Action for NRC Order EA-13-109 Reliable Hardened Containment Vents Capable of Operation Under Severe Accident Conditions12 April 2018Southern Nuclear
Wheat J
Unit 1, Completion of Required Action for NRC Order EA-13-109 Reliable Hardened Containment Vents Capable of Operation Under Severe Accident ConditionsOther
NL-18-1333, Completion of Required Action for NRC Order EA-13-109 Reliable Hardened Containment Vents Capable of Operation Under Severe Accident Conditions12 November 2018Southern Nuclear
Gayheart C
Completion of Required Action for NRC Order EA-13-109 Reliable Hardened Containment Vents Capable of Operation Under Severe Accident ConditionsOther
ML19045A49128 January 2019Southern Nuclear
Enfinger T
(EA-13-109) HCVS FIP Follow-UpOther
ML19044A5553 April 2019Brett Titus
Beyond-Design-Basis Management Branch
Safety Evaluation Regarding Implementation of Hardened Containment Vents Capable of Operation Under Severe Accident Conditions Related to Order EA-13-109Approval