Issue date | Title | From | To | |
---|---|---|---|---|
ML18144A011 | 5 November 1985 | Requests Partial Exemption from GDC 4,eliminating Protection Against Dynamic Effects of Postulated Pipe Rupture on Primary Sys Components & Piping,Per Generic Ltr 84-04. Snubbers Will Be Removed During 1986 Refueling Outage | Dominion Stewart W | Varga S Office of Nuclear Reactor Regulation Harold Denton |
ML18144A043 | 30 November 1985 | VEPCO Surry Units 1 & 2 RCS Leakage Detection Assessment for Elimination of RCS Main Loop Pipe Break Protective Devices. | Dominion | |
ML18144A044 | 30 November 1985 | VEPCO Surry Units 1 & 2 Safety Balance Assessment for Elimination of RCS Main Loop Pipe Break Protective Activities. | Dominion | |
ML18144A042 | 30 November 1985 | VEPCO Surry Units 1 & 2 RCS Loads & Component Support Margins Evaluation of Elimination of RCS Main Loop Pipe Break Protective Devices. | Dominion | |
ML18144A040 | 3 December 1985 | Forwards Repts in Support of 851105 Request for Exemption from GDC 4,eliminating Protection Against Dynamic Effects of Postulated Pipe Rupture on Primary Sys Components & Piping | Dominion Stewart W | Varga S Office of Nuclear Reactor Regulation Harold Denton |
ML18149A144 | 30 April 1986 | Application for Amends to Licenses DPR-32 & DPR-37,revising Tech Specs to Add License Condition Authorizing Rev to Reactor Coolant Pump & Steam Generator Support Design to Mitigate Pipe Rupture Events | Dominion Stewart W | Office of Nuclear Reactor Regulation Rubenstein L Harold Denton |
ML18149A146 | 30 April 1986 | Proposed Tech Specs,Authorizing Rev to Reactor Coolant Pump & Steam Generator Support Design.Safety Evaluation Encl | Dominion | |
ML18149A248 | 15 August 1986 | Forwards Final Response Re Implementation Status of Various Generic Items,Per 860430 Request | Dominion Stewart W | Office of Nuclear Reactor Regulation Rubenstein L Harold Denton |
NRC Generic Letter 1989-21 | 19 October 1989 | NRC Generic Letter 1989-021: Request for Information Concerning Status of Implementation of Unresolved Safety Issue (USI) Requirements | Partlow J Office of Nuclear Reactor Regulation | |
ML18153B999 | 29 November 1989 | Forwards Response to Generic Ltr 89-21 Re Status of Implementation of USI Requirements at Facilities.Actions Re USI A-26, Reactor Vessel Pressure Transient Protection Completed Via Amends 55 & 56 to SER on 800304 | Dominion Stewart W | Office of Information Resources Management |
ML19058A583 | 27 September 2018 | UFSAR Chapter 14-18 | Cotton K Plant Licensing Branch II | Dominion |
ML19095A605 | 31 March 2019 | Enclosure 5 - Topical Report WCAP-15550-NP, Rev 2, Technical Justification for Eliminating Large Primary Loop Pipe Rupture as the Structural Design Basis for Surry Units 1 and 2 Nuclear Power Plants for the Subsequent License Renewal Progra | Westinghouse Dominion | Office of Nuclear Reactor Regulation |
ML21210A135 | 30 September 2020 | 2 to Updated Final Safety Analysis Report, Chapter 15, Structures and Construction (EPID L-2020-LRO-0076) - Redacted | Dominion | Office of Nuclear Reactor Regulation |
ML21175A185 | 20 August 2021 | Issuance of Amendment Nos. 304 and 304 Leak-Before-Break for Pressurizer Surge, Residual Heat Removal, Safety Injection Accumulator, Reactor Coolant System Bypass and Safety Injection Lines | Plant Licensing Branch II Vaughn Thomas | Dominion Stoddard D |