Semantic search
Jump to navigation
Jump to search
Issue date | Title | Topic | |
---|---|---|---|
ML20209F652 | 30 June 1999 | Annual Operations Rept for Iowa State Univ UTR-10 Reactor for 980701-990630. with | |
ML20198R254 | 6 January 1999 | Rev 0 to Draft Decommissioning Plan for Iowa State Univ UTR-10 Reactor | |
ML20198R265 | 6 January 1999 | Rev 0 to Characterization Rept for Iowa State Univ UTR-10 Reactor | |
ML20236P078 | 30 June 1998 | Annual Operations Rept Iowa State Univ UTR-10 Reactor for Jul 1997-June 1998 | |
ML20217H313 | 30 March 1998 | Safety Evaluation Supporting Amend 12 to License R-59 | Grace period |
ML20198R278 | 6 January 1998 | Appendices to Characterization Rept for Iowa State Univ UTR-10 Reactor | |
ML20151K238 | 30 June 1997 | Annual Operations Rept IA State Univ UTR-10 Reactor for 960701-970630 | Shutdown Margin Grace period |
ML20132B070 | 13 December 1996 | Safety Evaluation Supporting Amend 11 to License R-59 | |
ML20116B878 | 30 June 1996 | Annual Operations Rept for Iowa State Univ UTR-10 Reactor 950701-960630 | |
ML20092B435 | 30 June 1995 | Annual Operations Rept Iowa State Univ UTR-10 Reactor Jul 1994 - June 1995 | |
ML20084V196 | 26 May 1995 | Requalification Program for Licensed Operators of UTR-10 Facility | Power change |
ML20070J522 | 30 June 1994 | Annual Operations Rept IA State Univ UTR-10 Reactor 930701- 940630 | |
ML20058F792 | 29 November 1993 | Safety Evaluation Supporting Amend 10 to License R-59 | |
ML20046A389 | 30 June 1993 | Annual Operating Rept for IA State Univs UTR-10 Reactor, for 930701-0630.W/930720 Ltr | |
ML20099G904 | 30 June 1992 | Corrected Annual Operations Rept for Iowa State Univ, for Jul 1991 Through June 1992 | Fuel cladding |
ML20085N393 | 29 October 1991 | Deficiency Rept Re Discoloration of Low Enrichment U Fuel Plate Cladding.Initially Reported Via 911029 Telcon.Order Prohibiting Further Operation of Reactor Issued on 910920 & Plate Removed.Investigation Into Cause Underway | Fuel cladding |
ML20085K977 | 25 October 1991 | Special Rept:On 911023,roll Pin Cracking Observed in Fuel Handling Cones.Cause Unknown.Reactor Operations Suspended Until Cause of Pin Cracking Determined & Appropriate Replacement for Pins Identified & Installed | Fuel cladding |
ML20077L204 | 30 June 1991 | Annual Operations Rept for Iowa State Univ Research Reactor for Jul 1990 to June 1991 | |
ML20059J908 | 12 September 1990 | Safety Evaluation Supporting Conversion Order for License R-59 to Allow Facility to Convert from High Enriched to Low Enriched U Fuel | |
ML20058L351 | 30 June 1990 | Annual Operations Rept for Iowa State Univ Research Reactor for Jul 1989 - June 1990 | |
ML20247N146 | 30 June 1989 | Annual Operations Rept for Iowa State Univ Research Reactor, 880701-890630 | Earthquake |
ML20151Q593 | 30 June 1988 | Annual Opeations Rept for Iowa State Univ Research Reactor for Jul 1987 - June 1988 | |
ML20236C230 | 30 June 1987 | Annual Operations Rept for Jul 1986 - June 1987 | |
ML20215L543 | 17 June 1987 | Special Rept:On 870603,during Normal Startup of Reactor,One Linear Percent Channel Failed to Indicate Power Level on Panel Meter.Caused by Malfunction of Test Switch.Maint Practice Changed to Include Cleaning of Test Switch | |
ML20204F225 | 30 June 1986 | Annual Operations Rept for Jul 1985 - June 1986 | |
ML20148E013 | 27 September 1978 | Ro:On 780914,shim-safety Rod UTR-10 Failed to Insert During Manual Scram.Caused by Loose Position Potentiometer Mounting Nut.Lock Washer Added to Potentiometer Mounting Hardware |