Semantic search

Jump to navigation Jump to search
 Issue dateTitleTopic
ML20209F65230 June 1999Annual Operations Rept for Iowa State Univ UTR-10 Reactor for 980701-990630. with
ML20198R2546 January 1999Rev 0 to Draft Decommissioning Plan for Iowa State Univ UTR-10 Reactor
ML20198R2656 January 1999Rev 0 to Characterization Rept for Iowa State Univ UTR-10 Reactor
ML20236P07830 June 1998Annual Operations Rept Iowa State Univ UTR-10 Reactor for Jul 1997-June 1998
ML20217H31330 March 1998Safety Evaluation Supporting Amend 12 to License R-59Grace period
ML20198R2786 January 1998Appendices to Characterization Rept for Iowa State Univ UTR-10 Reactor
ML20151K23830 June 1997Annual Operations Rept IA State Univ UTR-10 Reactor for 960701-970630Shutdown Margin
Grace period
ML20132B07013 December 1996Safety Evaluation Supporting Amend 11 to License R-59
ML20116B87830 June 1996Annual Operations Rept for Iowa State Univ UTR-10 Reactor 950701-960630
ML20092B43530 June 1995Annual Operations Rept Iowa State Univ UTR-10 Reactor Jul 1994 - June 1995
ML20084V19626 May 1995Requalification Program for Licensed Operators of UTR-10 FacilityPower change
ML20070J52230 June 1994Annual Operations Rept IA State Univ UTR-10 Reactor 930701- 940630
ML20058F79229 November 1993Safety Evaluation Supporting Amend 10 to License R-59
ML20046A38930 June 1993Annual Operating Rept for IA State Univs UTR-10 Reactor, for 930701-0630.W/930720 Ltr
ML20099G90430 June 1992Corrected Annual Operations Rept for Iowa State Univ, for Jul 1991 Through June 1992Fuel cladding
ML20085N39329 October 1991Deficiency Rept Re Discoloration of Low Enrichment U Fuel Plate Cladding.Initially Reported Via 911029 Telcon.Order Prohibiting Further Operation of Reactor Issued on 910920 & Plate Removed.Investigation Into Cause UnderwayFuel cladding
ML20085K97725 October 1991Special Rept:On 911023,roll Pin Cracking Observed in Fuel Handling Cones.Cause Unknown.Reactor Operations Suspended Until Cause of Pin Cracking Determined & Appropriate Replacement for Pins Identified & InstalledFuel cladding
ML20077L20430 June 1991Annual Operations Rept for Iowa State Univ Research Reactor for Jul 1990 to June 1991
ML20059J90812 September 1990Safety Evaluation Supporting Conversion Order for License R-59 to Allow Facility to Convert from High Enriched to Low Enriched U Fuel
ML20058L35130 June 1990Annual Operations Rept for Iowa State Univ Research Reactor for Jul 1989 - June 1990
ML20247N14630 June 1989Annual Operations Rept for Iowa State Univ Research Reactor, 880701-890630Earthquake
ML20151Q59330 June 1988Annual Opeations Rept for Iowa State Univ Research Reactor for Jul 1987 - June 1988
ML20236C23030 June 1987Annual Operations Rept for Jul 1986 - June 1987
ML20215L54317 June 1987Special Rept:On 870603,during Normal Startup of Reactor,One Linear Percent Channel Failed to Indicate Power Level on Panel Meter.Caused by Malfunction of Test Switch.Maint Practice Changed to Include Cleaning of Test Switch
ML20204F22530 June 1986Annual Operations Rept for Jul 1985 - June 1986
ML20148E01327 September 1978Ro:On 780914,shim-safety Rod UTR-10 Failed to Insert During Manual Scram.Caused by Loose Position Potentiometer Mounting Nut.Lock Washer Added to Potentiometer Mounting Hardware