ML20087L5712 February 1976AO 76-3:during Refueling Outage from 751116-760108,nine Valves Exhibited Leak Rate in Excess of 2000 Cc/Minute. Caused by Loose Body to Bonnet Joint.Bolting Tightened
ML20087K9388 March 1975AO 50-266/75-4:on 750226,air Ejector Discharge Gas Monitor R15 Pegged High,Then Dropped Low.Operator Manually Secured RCS Letdown & Went to Auxiliary Bldg to Assist in Locating Suspected Leak
ML20087L09118 February 1975AO 75-3:on 750208,mechanical Latching Mechanism on Redundant Solenoid Trip Vent Valve 2018C on Main Steam Stop Valve a Failed to Unlatch When Solenoid Deenergized.Caused by Improper Rotation of Rollers as Designed
ML20087L20928 January 1975AO 75-1:on 750120,first of 4 Tanks of Sludge Lancing Waste Sampled & Iodine Levels Found Approx 9 Times Max Permissable Concentration.Caused by Fuel Cladding Leaks Plus Small primary-to-secondary Leak in Steam Generator aFuel cladding
ML20087L26622 November 1974Ao:On 741009,while Personnel Exiting Containment Via 66 Ft Level Personnel Airlock,Air Heard Escaping Following Closing of Inner Door.Caused by Open 3/8-inch Valve on Pressure Gauge Instrument Line.Valve Removed.Served No Purpose
ML20087L31030 August 1974Ao:On 740821,recheck of Control Panel Indicated Above Normal Operating Pressure & Water Level Conditions Existed in Blowdown Evaporator.Caused by Steam Leaking at Steam Supply Control Valve
ML20087L31927 August 1974Ao:On 740815,during Monthly Surveillance Test,Steam Generator B Level Channel 472,lo-lo Level Bistable Would Not Trip When Tested.Caused by Failed Silicon Controlled Rectifier.Rectifier Replaced
ML20087L32522 July 1974Ao:On 740711,rereview of Tech Spec Changes Allowed part-length Rods to Be Inserted Not More than 70%.On 740529,part-length Rods Inserted to Max Integral Worth, 82.5% & Remained in That Position Until 740608
ML20087L34413 June 1974Ao:On 740325,valve Permitting 150 Gallons of Reactor Coolant to Enter Waste Holdup Tank Inadvertently Opened.Caused by Personnel Error.Operator Reprimanded & Reminded That Utmost Care Must Be Exercised on Valve Lineup Operations
ML20087L3368 June 1974Ao:On 740529,minor Leak Discovered in Main Steam Safety Valve & Secondary Side Steam Pressure Substantially Reduced to Reseat Safety Valve & Terminate Minor Leak. Caused by Incorrect Concentration of Borated WaterBoric Acid
Shutdown Margin
ML20087L54814 May 1974Ao:On 740509,auxiliary Bldg Stack Monitor R14 Alarmed at Setpoint During Refueling Activities of 4,000 Counts Per Minute Indicating Release of Radioactivity.Caused by Isolation of Vol Control Tank for Venting
ML20087L5933 May 1974Ao:On 740406,during Performance of Containment Isolation Valves Leak Tests,Two second-off Valves from Containment Found to Leak in Excess of 2000 Cc/Minute.Cause Not Stated. Leak Tests Ongoing.Valves Will Be Repaired & Retested
ML20087L60317 April 1974Ao:On 740407,while Running Motor Driven Auxiliary Feed Pump a to Maintain Steam Generator Water Levels,Operator Noted Pump Not Delivering at Adequate Feedwater Flow Rate.Caused by Strainer Fitted in Flanged Position
ML20087L61111 April 1974Ao:On 740404,following Completion of Operations Refueling Tests,Isolation Valves 1AOV-2084 & 1AOV-2083 Closed Automatically on Signal from R-19 Process Monitor,Indicating Liquid W/Radioactivity Above Normal Levels
ML20087L6204 April 1974Ao:On 730329,when Drain Cap Removed from Penetration 32,air Blew Lightly for Several Seconds & Showed No Signs of Diminishing.Caused by Leak of Sensing Line within Penetration Boundary.Line Will Be Repaired
ML20087L6266 February 1974Ao:On 740125,auxiliary Bldg Stack Monitor R-14 Alarmed Indicating Release of Radioactivity.Caused by Increased Pressure Attained in Holdup Tanks & Suction of Waste Gas Compressors
ML20087L6973 November 1973Ao:On 731013,boric Acid Storage Tank B Placed in Svc & Boric Acid Tank a Concentration Known to Have Fallen Below Tech Spec Limit Immediately Prior to Transfer of Tanks. Caused by Two Personnel ErrorsBoric Acid
ML20084A09029 October 1973Ao:On 730915,following Investigation of Excess Letdown Line Leak,Valve 1MOV-1299 Downstream Seat Protruded from Valve Body & Crack Discovered in Upper Portion of Downstream Seat Ring.Cause Unknown.Vendor Notified of Valve Problem
ML20087L62916 July 1973Ao:On 730708,high Level Alarm on Facade Sump Received in Main Control Room.Caused by Small But Steady Flow Into Sump from Unknown Source.Retransfer of Borated Water from Refueling Water Storage Tank Instigated
ML20087L63128 May 1973Ao:On 730512,to Expedite Shutdown & Draining of Radwaste Sys Waste Evaporator,Operating Personnel Manually Lifted One of Two Evaporator Safety Valves.Following Shutdown,Valve Remained in Raised Condition.Procedure Pbnp 4.17 Expanded
ML19317D46611 August 1971Ao:On 710803,release of Radioactive Liquid Into Sewage Retention Pond Resulted from Overflow of Unit 2 Facade Sump During Filling Operation.Caused by Problems W/Facade DrainBoric Acid