Constellation@
Dresden Nuclear Power Station 6500 North Dresden Road Morris, IL 60450 March 28, 2025 SVPL TR: #25-0016 Document Control Desk Director, Division of Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, DC 20555-0001
Subject:
Dresden Nuclear Power Station, Units 1, 2, and 3 Facility Operating License No. DPR-2 Renewed Facility Operating License Nos. DPR-19 and DPR-25 NRC Docket Nos.50-010, 50-237, 50-249, and 72-37 Registration of Use of Casks to Store Spent Fuel 10 CFR 72.212 In accordance with 10 CFR 72.212, "Conditions of general license issued under§ 72.210,"
paragraph (b)(2), Constellation Energy Generation, LLC (CEG) is registering, with the NRC, the use of two casks under the general license to store spent fuel at Dresden Nuclear Power Station (DNPS). The casks were placed into service with spent fuel on March 13, 2025, and March 20, 2025. This registration is required to be submitted within 30 days of the first placement. The following information is provided in accordance with 10 CFR 72.212(b)(2):
Licensee Name Constellation Enerav Generation, LLC Dresden Nuclear Power Station Licensee Address 6500 N. Dresden Road Morris, IL 60450 Reactor License Number DPR-2, (renewed) DPR-19, and (renewed) DPR-25 Reactor Docket Number 50-010, 50-237, and 50-249 Independent Spent Fuel Storage Installation 72-37 Docket Number Contact Person and Title Daniel J. Murphy, Regulatory Assurance Manaaer
March 28, 2025 U.S. Nuclear Regulatory Commission Page 2 Cask Certificate Number:
Cask Model Number:
Service Date:
Cask Placement 1014, Amendment 8, Revision 1 HI-STORM 1 00S March 13, 2025 Multi-Purpose Canister Type 68M, Serial No. 843, HI-STORM Cask Identification Number:
Cask Certificate Number:
Cask Model Number:
Service Date:
1 00S Serial No. 1773 Cask Placement 1014, Amendment 8, Revision 1 HI-STORM 1 00S March 20, 2025 Multi-Purpose Canister Type 68M, Serial No. 840, HI-STORM Cask Identification Number:
1 00S Serial No. 1720 There are no regulatory commitments contained within this letter.
Should you have any questions concerning this letter, please contact Daniel J. Murphy, Regulatory Assurance Manager, at (779) 231-7443.
Respectfully,
~~~x 8, -t 1~. C? "- {-... \\ / ~ ( ~
1'\\ tJ\\_ t.,IA d. ~r Carolyne Joseph Site Vice President, Dresden Nuclear Power Station Constellation Energy Generation, LLC