RS-16-062, Additional Information Regarding License Amendment Request for Spent Fuel Storage Pool Criticality Methodology for Fuel Channel Bow/Bulge

From kanterella
(Redirected from RS-16-062)
Jump to navigation Jump to search

Additional Information Regarding License Amendment Request for Spent Fuel Storage Pool Criticality Methodology for Fuel Channel Bow/Bulge
ML16069A217
Person / Time
Site: Quad Cities  Constellation icon.png
Issue date: 03/09/2016
From: Simpson P
Exelon Generation Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
2127008-AFF-01, RS-16-062
Download: ML16069A217 (8)


Text

4300 Winfield Road Warrenville, IL 60555 630 657 2000 Office RS-16-062 March 9, 2016 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Quad Cities Nuclear Power Station, Units 1 and 2 Renewed Facility Operating License Nos. DPR-29 and DPR-30 NRC Docket Nos. 50-254 and 50-265

Subject:

Additional Information Regarding License Amendment Request for Spent Fuel Storage Pool Criticality Methodology for Fuel Channel Bow/Bulge

Reference:

Letter from P. R. Simpson (Exelon Generation Company, LLC) to U.S. NRC, "Request for License Amendment Regarding Spent Fuel Storage Pool Criticality Methodology for Fuel Channel Bow/Bulge," dated December 14, 2015 In the Reference, Exelon Generation Company, LLC (EGC) requested an amendment to Renewed Facility Operating License Nos. DPR-29 and DPR-30 for Quad Cities Nuclear Power Station (QCNPS), Units 1 and 2, respectively. The proposed change would allow use of a new Criticality Safety Analysis (CSA) fuel channel bow/bulge methodology for performing the criticality safety evaluation for the new ATRIUM 10XM fuel design in the spent fuel pool. of the Reference letter contained information proprietary to Holtec International, and as such, was supported by an affidavit signed by Holtec International, the owner of the information. In a recent telephone discussion, the NRC notified EGC of a deficiency that was identified in the Holtec International affidavit that was provided in Attachment 6 of the Reference, and requested a revised affidavit to correct the identified deficiency. The requested information is attached.

EGC has reviewed the information supporting a finding of no significant hazards consideration, and the environmental consideration, that were previously provided to the NRC in Attachment 1 of the Reference. The additional information provided in this submittal does not affect the bases for concluding that the proposed license amendment does not involve a significant hazards consideration. In addition, the additional information provided in this submittal does not affect the bases for concluding that neither an environmental impact statement nor an environmental assessment needs to be prepared in connection with the proposed amendment.

March 9, 2016 U.S. Nuclear Regulatory Commission Page2 There are no regulatory commitments contained in this letter. Should you have any questions concerning this letter, please contact Mr. Kenneth M. Nicely at (630) 657-2803.

I declare under penalty of perjury that the foregoing is true and correct. Executed on the 9th day of March 2016.

RTictfully, PJ:~f(

Manager - Licensing

Attachment:

Holtec International Affidavit cc:

NRC Regional Administrator, Region Ill NRC Senior Resident Inspector-Quad Cities Nuclear Power Station Illinois Emergency Management Agency-Division of Nuclear Safety

ATTACHMENT Holtec International Affidavit

Holtec Center, 555 Lincoln Drive West, Marlton, NJ 08053 Telephone (856) 797-0900 Fax (856) 797-0909 Holtec International Document ID 2127008-AFF-01 AFFIDAVIT PURSUANT TO 10 CFR 2.390 1 of 5 I, Debabrata (Debu) Mitra Majumdar, being duly sworn, depose and state as follows:

(1)

I have reviewed the information described in paragraph (2) which is sought to be withheld, and am authorized to apply for its withholding.

(2)

The information sought to be withheld is information provided in the following reports.

a.

Table 1: Criticality Safety Analysis (CSA) Approach Comparison b.

Table 2: Comparison of the ATRIUM 10XM and SVEA-96 Optima Biases and Uncertainties.

These tables contain Holtec proprietary information. A non-proprietary version of the tables is provided for disclosure.

(3)

In making this application for withholding of proprietary information of which it is the owner, Holtec International relies upon the exemption from disclosure set forth in the Freedom of Information Act ("FOIA"), 5 USC Sec. 552(b)(4) and the Trade Secrets Act, 18 USC Sec. 1905, and NRC regulations 10CFR Part 9.17(a)(4), 2.390(a)(4), and 2.390(b)(1) for "trade secrets and commercial or financial information obtained from a person and privileged or confidential" (Exemption 4). The material for which exemption from disclosure is here sought is all "confidential commercial information", and some portions also qualify under the narrower definition of "trade secret", within the meanings assigned to those terms for purposes of FOIA Exemption 4 in, respectively, Critical Mass Energy Project v. Nuclear Regulatory Commission, 975F2d871 (DC Cir. 1992), and Public Citizen Health Research Group v. FDA, 704F2d1280 (DC Cir. 1983).

Holtec International Document ID 2127008-AFF-01 AFFIDAVIT PURSUANT TO 10 CFR 2.390 2 of 5 (4)

Some examples of categories of information which fit into the definition of proprietary information are:

a.

Information that discloses a process, method, or apparatus, including supporting data and analyses, where prevention of its use by Holtec's competitors without license from Holtec International constitutes a competitive economic advantage over other companies; b.

Information which, if used by a competitor, would reduce his expenditure of resources or improve his competitive position in the design, manufacture, shipment, installation, assurance of quality, or licensing of a similar product.

c.

Information which reveals cost or price information, production, capacities, budget levels, or commercial strategies of Holtec International, its customers, or its suppliers;

d.

Information which reveals aspects of past, present, or future Holtec International customer-funded development plans and programs of potential commercial value to Holtec International;

e.

Information which discloses patentable subject matter for which it may be desirable to obtain patent protection.

The information sought to be withheld is considered to be proprietary for the reasons set forth in paragraph 4.b, above.

(5)

The information sought to be withheld is being submitted to the NRC in confidence. The information (including that compiled from many sources) is of a sort customarily held in confidence by Holtec International, and is in fact so held. The information sought to be withheld has, to the best of my knowledge and belief, consistently been held in confidence by Holtec International. No public disclosure has been made, and it is not available in public sources. All disclosures to third parties, including any required transmittals to the NRC, have been made, or must be made, pursuant to regulatory provisions or

Holtec International Document ID 2127008-AFF-01 AFFIDAVIT PURSUANT TO 10 CFR 2.390 3 of 5 proprietary agreements which provide for maintenance of the information in confidence. Its initial designation as proprietary information, and the subsequent steps taken to prevent its unauthorized disclosure, are as set forth in paragraphs (6) and (7) following.

(6)

Initial approval of proprietary treatment of a document is made by the manager of the originating component, the person most likely to be acquainted with the value and sensitivity of the information in relation to industry knowledge.

Access to such documents within Holtec International is limited on a "need to know" basis.

(7)

The procedure for approval of external release of such a document typically requires review by the staff manager, project manager, principal scientist or other equivalent authority, by the manager of the cognizant marketing function (or his designee), and by the Legal Operation, for technical content, competitive effect, and determination of the accuracy of the proprietary designation.

Disclosures outside Holtec International are limited to regulatory bodies, customers, and potential customers, and their agents, suppliers, and licensees, and others with a legitimate need for the information, and then only in accordance with appropriate regulatory provisions or proprietary agreements.

(8)

The information classified as proprietary was developed and compiled by Holtec International at a significant cost to Holtec International. This information is classified as proprietary because it contains detailed descriptions of analytical approaches and methodologies not available elsewhere. This information would provide other parties, including competitors, with information from Holtec International's technical database and the results of evaluations performed by Holtec International. A substantial effort has been expended by Holtec International to develop this information. Release of this information would improve a competitor's position because it would enable Holtecs competitor to copy our technology and offer it for sale in competition with our company, causing us financial injury.

Holtec International Document ID 2127008-AFF-01 AFFIDAVIT PURSUANT TO 10 CFR 2.390 4 of 5 (9)

Public disclosure of the information sought to be withheld is likely to cause substantial harm to Holtec International's competitive position and foreclose or reduce the availability of profit-making opportunities. The information is part of Holtec International's comprehensive spent fuel storage technology base, and its commercial value extends beyond the original development cost. The value of the technology base goes beyond the extensive physical database and analytical methodology, and includes development of the expertise to determine and apply the appropriate evaluation process.

The research, development, engineering, and analytical costs comprise a substantial investment of time and money by Holtec International.

The precise value of the expertise to devise an evaluation process and apply the correct analytical methodology is difficult to quantify, but it clearly is substantial.

Holtec International's competitive advantage will be lost if its competitors are able to use the results of the Holtec International experience to normalize or verify their own process or if they are able to claim an equivalent understanding by demonstrating that they can arrive at the same or similar conclusions.

The value of this information to Holtec International would be lost if the information were disclosed to the public. Making such information available to competitors without their having been required to undertake a similar expenditure of resources would unfairly provide competitors with a windfall, and deprive Holtec International of the opportunity to exercise its competitive advantage to seek an adequate return on its large investment in developing these very valuable analytical tools.

Holtec International Document ID 2127008-AFF-Ol AFFIDAVIT PURSUANT TO 10 CFR 2.390 STATE OF NEW JERSEY

)

)

ss:

COUNTY OF BURLINGTON )

Mr. Debabrata (Debu) Mitra Majumdar, being duly sworn, deposes and says:

That he has read the foregoing affidavit and the matters stated therein are true and correct to the best of his knowledge, information, and belief.

Executed at Marlton, New Jersey, this gth day of March, 2016 Subscribed and sworn before me this

~*~~*

Debabrata (Debu) Mitra Majumdar, Ph.D.

Corporate Director - Engineering Analysis Holtec International 8

day of _____ M_ar_ch-'----' 2016.

5 of5 MARIA C. MASSI NOTARY PUBLIC OF NEW JERSEY My Commission Expires April 25, 2020

4300 Winfield Road Warrenville, IL 60555 630 657 2000 Office RS-16-062 March 9, 2016 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Quad Cities Nuclear Power Station, Units 1 and 2 Renewed Facility Operating License Nos. DPR-29 and DPR-30 NRC Docket Nos. 50-254 and 50-265

Subject:

Additional Information Regarding License Amendment Request for Spent Fuel Storage Pool Criticality Methodology for Fuel Channel Bow/Bulge

Reference:

Letter from P. R. Simpson (Exelon Generation Company, LLC) to U.S. NRC, "Request for License Amendment Regarding Spent Fuel Storage Pool Criticality Methodology for Fuel Channel Bow/Bulge," dated December 14, 2015 In the Reference, Exelon Generation Company, LLC (EGC) requested an amendment to Renewed Facility Operating License Nos. DPR-29 and DPR-30 for Quad Cities Nuclear Power Station (QCNPS), Units 1 and 2, respectively. The proposed change would allow use of a new Criticality Safety Analysis (CSA) fuel channel bow/bulge methodology for performing the criticality safety evaluation for the new ATRIUM 10XM fuel design in the spent fuel pool. of the Reference letter contained information proprietary to Holtec International, and as such, was supported by an affidavit signed by Holtec International, the owner of the information. In a recent telephone discussion, the NRC notified EGC of a deficiency that was identified in the Holtec International affidavit that was provided in Attachment 6 of the Reference, and requested a revised affidavit to correct the identified deficiency. The requested information is attached.

EGC has reviewed the information supporting a finding of no significant hazards consideration, and the environmental consideration, that were previously provided to the NRC in Attachment 1 of the Reference. The additional information provided in this submittal does not affect the bases for concluding that the proposed license amendment does not involve a significant hazards consideration. In addition, the additional information provided in this submittal does not affect the bases for concluding that neither an environmental impact statement nor an environmental assessment needs to be prepared in connection with the proposed amendment.

March 9, 2016 U.S. Nuclear Regulatory Commission Page2 There are no regulatory commitments contained in this letter. Should you have any questions concerning this letter, please contact Mr. Kenneth M. Nicely at (630) 657-2803.

I declare under penalty of perjury that the foregoing is true and correct. Executed on the 9th day of March 2016.

RTictfully, PJ:~f(

Manager - Licensing

Attachment:

Holtec International Affidavit cc:

NRC Regional Administrator, Region Ill NRC Senior Resident Inspector-Quad Cities Nuclear Power Station Illinois Emergency Management Agency-Division of Nuclear Safety

ATTACHMENT Holtec International Affidavit

Holtec Center, 555 Lincoln Drive West, Marlton, NJ 08053 Telephone (856) 797-0900 Fax (856) 797-0909 Holtec International Document ID 2127008-AFF-01 AFFIDAVIT PURSUANT TO 10 CFR 2.390 1 of 5 I, Debabrata (Debu) Mitra Majumdar, being duly sworn, depose and state as follows:

(1)

I have reviewed the information described in paragraph (2) which is sought to be withheld, and am authorized to apply for its withholding.

(2)

The information sought to be withheld is information provided in the following reports.

a.

Table 1: Criticality Safety Analysis (CSA) Approach Comparison b.

Table 2: Comparison of the ATRIUM 10XM and SVEA-96 Optima Biases and Uncertainties.

These tables contain Holtec proprietary information. A non-proprietary version of the tables is provided for disclosure.

(3)

In making this application for withholding of proprietary information of which it is the owner, Holtec International relies upon the exemption from disclosure set forth in the Freedom of Information Act ("FOIA"), 5 USC Sec. 552(b)(4) and the Trade Secrets Act, 18 USC Sec. 1905, and NRC regulations 10CFR Part 9.17(a)(4), 2.390(a)(4), and 2.390(b)(1) for "trade secrets and commercial or financial information obtained from a person and privileged or confidential" (Exemption 4). The material for which exemption from disclosure is here sought is all "confidential commercial information", and some portions also qualify under the narrower definition of "trade secret", within the meanings assigned to those terms for purposes of FOIA Exemption 4 in, respectively, Critical Mass Energy Project v. Nuclear Regulatory Commission, 975F2d871 (DC Cir. 1992), and Public Citizen Health Research Group v. FDA, 704F2d1280 (DC Cir. 1983).

Holtec International Document ID 2127008-AFF-01 AFFIDAVIT PURSUANT TO 10 CFR 2.390 2 of 5 (4)

Some examples of categories of information which fit into the definition of proprietary information are:

a.

Information that discloses a process, method, or apparatus, including supporting data and analyses, where prevention of its use by Holtec's competitors without license from Holtec International constitutes a competitive economic advantage over other companies; b.

Information which, if used by a competitor, would reduce his expenditure of resources or improve his competitive position in the design, manufacture, shipment, installation, assurance of quality, or licensing of a similar product.

c.

Information which reveals cost or price information, production, capacities, budget levels, or commercial strategies of Holtec International, its customers, or its suppliers;

d.

Information which reveals aspects of past, present, or future Holtec International customer-funded development plans and programs of potential commercial value to Holtec International;

e.

Information which discloses patentable subject matter for which it may be desirable to obtain patent protection.

The information sought to be withheld is considered to be proprietary for the reasons set forth in paragraph 4.b, above.

(5)

The information sought to be withheld is being submitted to the NRC in confidence. The information (including that compiled from many sources) is of a sort customarily held in confidence by Holtec International, and is in fact so held. The information sought to be withheld has, to the best of my knowledge and belief, consistently been held in confidence by Holtec International. No public disclosure has been made, and it is not available in public sources. All disclosures to third parties, including any required transmittals to the NRC, have been made, or must be made, pursuant to regulatory provisions or

Holtec International Document ID 2127008-AFF-01 AFFIDAVIT PURSUANT TO 10 CFR 2.390 3 of 5 proprietary agreements which provide for maintenance of the information in confidence. Its initial designation as proprietary information, and the subsequent steps taken to prevent its unauthorized disclosure, are as set forth in paragraphs (6) and (7) following.

(6)

Initial approval of proprietary treatment of a document is made by the manager of the originating component, the person most likely to be acquainted with the value and sensitivity of the information in relation to industry knowledge.

Access to such documents within Holtec International is limited on a "need to know" basis.

(7)

The procedure for approval of external release of such a document typically requires review by the staff manager, project manager, principal scientist or other equivalent authority, by the manager of the cognizant marketing function (or his designee), and by the Legal Operation, for technical content, competitive effect, and determination of the accuracy of the proprietary designation.

Disclosures outside Holtec International are limited to regulatory bodies, customers, and potential customers, and their agents, suppliers, and licensees, and others with a legitimate need for the information, and then only in accordance with appropriate regulatory provisions or proprietary agreements.

(8)

The information classified as proprietary was developed and compiled by Holtec International at a significant cost to Holtec International. This information is classified as proprietary because it contains detailed descriptions of analytical approaches and methodologies not available elsewhere. This information would provide other parties, including competitors, with information from Holtec International's technical database and the results of evaluations performed by Holtec International. A substantial effort has been expended by Holtec International to develop this information. Release of this information would improve a competitor's position because it would enable Holtecs competitor to copy our technology and offer it for sale in competition with our company, causing us financial injury.

Holtec International Document ID 2127008-AFF-01 AFFIDAVIT PURSUANT TO 10 CFR 2.390 4 of 5 (9)

Public disclosure of the information sought to be withheld is likely to cause substantial harm to Holtec International's competitive position and foreclose or reduce the availability of profit-making opportunities. The information is part of Holtec International's comprehensive spent fuel storage technology base, and its commercial value extends beyond the original development cost. The value of the technology base goes beyond the extensive physical database and analytical methodology, and includes development of the expertise to determine and apply the appropriate evaluation process.

The research, development, engineering, and analytical costs comprise a substantial investment of time and money by Holtec International.

The precise value of the expertise to devise an evaluation process and apply the correct analytical methodology is difficult to quantify, but it clearly is substantial.

Holtec International's competitive advantage will be lost if its competitors are able to use the results of the Holtec International experience to normalize or verify their own process or if they are able to claim an equivalent understanding by demonstrating that they can arrive at the same or similar conclusions.

The value of this information to Holtec International would be lost if the information were disclosed to the public. Making such information available to competitors without their having been required to undertake a similar expenditure of resources would unfairly provide competitors with a windfall, and deprive Holtec International of the opportunity to exercise its competitive advantage to seek an adequate return on its large investment in developing these very valuable analytical tools.

Holtec International Document ID 2127008-AFF-Ol AFFIDAVIT PURSUANT TO 10 CFR 2.390 STATE OF NEW JERSEY

)

)

ss:

COUNTY OF BURLINGTON )

Mr. Debabrata (Debu) Mitra Majumdar, being duly sworn, deposes and says:

That he has read the foregoing affidavit and the matters stated therein are true and correct to the best of his knowledge, information, and belief.

Executed at Marlton, New Jersey, this gth day of March, 2016 Subscribed and sworn before me this

~*~~*

Debabrata (Debu) Mitra Majumdar, Ph.D.

Corporate Director - Engineering Analysis Holtec International 8

day of _____ M_ar_ch-'----' 2016.

5 of5 MARIA C. MASSI NOTARY PUBLIC OF NEW JERSEY My Commission Expires April 25, 2020