430 10 CFR 72.212 RS-13-199 August 12, 2013 ATTN: Document Control Desk Director, Division of Spent Fuel Storage and Transportation Office of Nuclear Material Safety and Safeguards U. S. Nuclear Regulatory Commission Washington, DC 20555-0001 Limerick Generating Station, Units 1 and 2 Facility Operating License Nos. NPF-39 and NPF-85 NRC Docket Nos. 50-352, 50-353, and 72-065
Subject:
Registration of Use of Cask to Store Spent Fuel In accordance with 10 CFR 72.212, "Conditions of general license issued under §72.210,"
paragraph (b)(2), Exelon Generation Company, LLC (EGC) is registering, with the NRC, the use of two casks under the general license to store spent fuel at Limerick Generating Station (LGS).
The casks were placed into service with stored spent fuel on July 13, 2013, and July 19, 2013, respectively. This registration is required to be submitted within 30 days. Accordingly, this submittal is due by August 12, 2013.
The following information is provided in accordance with 10 CFR 72.212(b)(2).
Licensee Name:
Exelon Generation Company, LLC Licensee Address:
Limerick Generating Station 3146 Sanatoga Road Pottstown, PA 19464 Reactor License Numbers:
NPF-39 and NPF-85 Reactor Docket Numbers:
50-352, 50-353 Independent Spent Fuel Storage Installation Docket Number:
72-065 Contact Name and
Title:
P. R. Simpson Manager - Licensing 1
RS-13-199 August 12, 2013 ATrN: Document Control Desk Director, Division of Spent Fuel Storage and Transportation Office of Nuclear Material Safety and Safeguards U. S. Nuclear Regulatory Commission Washington, DC 20555-0001
Subject:
Limerick Generating Station, Units 1 and 2 Facility Operating License Nos. NPF-39 and NPF-85 NRC Docket Nos. 50-352. 50-353. and 72-065 Registration of Use of Cask to Store Spent Fuel 10 CFR 72.212 In accordance with 10 CFR 72.212, "Conditions of general license issued under §72.21 0,"
paragraph (b)(2), Exelon Generation Company, LLC (EGC) is registering, with the NRC, the use of two casks under the general license to store spent fuel at Limerick Generating Station (LGS).
The casks were placed into service with stored spent fuel on July 13, 2013, and July 19, 2013, respectively. This registration is required to be submitted within 30 days. Accordingly, this submittal is due by August 12, 2013.
The follOwing information is provided in accordance with 10 CFR 72.212(b)(2).
Licensee Name:
Licensee Address:
Reactor License Numbers:
Reactor Docket Numbers:
Independent Spent Fuel Storage Installation Docket Number:
Contact Name and
Title:
Exelon Generation Company, LLC Limerick Generating Station 3146 Sanatoga Road Pottstown, PA 19464 NPF-39 and NPF-85 50-352, 50-353 72-065 P. R. Simpson Manager - Licensing
August 12, 2013 U. S. Nuclear Regulatory Commission Page 2 Cask Certificate Number:
Cask Model Number:
HSM Model Number:
Service Date:
Cask Identification Number:
HSM Identification Number:
Service Date:
Cask Identification Number:
HSM Identification Number:
1004, Amendment 10 NUHOMS-61 BTH HSM-H July 13 2013 LGS-61 BTH1-D-2-027 HSM-043 July 19, 2013 LGS-61 BTH 1-D-2-028 HSM-042 In addition, this letter provides the results of the thermal performance assessment of the first Dry Storage Canister (DSC) placed into service in an HSM -H type cask. This information is required by Certificate of Compliance (CoC) No. 1004, Amendment No.10, Attachment A, "Technical Specifications" (TS) 1.1.7, "Special Requirements for First System in Place."
TS 1.1.7 also requires the submittal of the same information for subsequently loaded DSCs with higher heat loads. The attachment to this letter provides the information required by TS 1.1.7 for the two DSCs listed above. This information was obtained using LGS procedure ST-6-114-360-0, "Independent Spent Fuel Storage Installation (ISFSI) Technical Specification Testing."
Should you have any questions, please contact Mr. John L. Schrage at (630) 657-2821.
Respectfully, Patrick R. Simpson Manager - Licensing
Attachment:
Thermal Performance Assessment Data, Limerick Generating Station, Independent Spent Fuel Storage Installation, 2013 Dry Cask Storage Campaign cc:
NRC Regional Administrator - Region I August 12, 2013 U. S. Nuclear Regulatory Commission Page 2 Cask Certificate Number:
Cask Model Number:
HSM Model Number:
Service Date:
Cask Identification Number:
HSM Identification Number:
Service Date:
Cask Identification Number:
HSM Identification Number:
1004, Amendment 10 NUHOMS-61 BTH HSM-H July 13 2013 LGS-61 BTH 1-0-2-027 HSM-043 July 19, 2013 LGS-61 BTH1-0-2-028 HSM-042 In addition, this letter provides the results of the thermal performance assessment of the first Ory Storage Canister (OSC) placed into service in an HSM-H type cask. This information is required by Certificate of Compliance (CoC) No.1 004, Amendment No.1 0, Attachment A, "Technical Specifications" (TS) 1.1.7, "Special Requirements for First System in Place."
TS 1.1.7 also requires the submittal of the same information for subsequently loaded OSCs with higher heat loads. The attachment to this letter provides the information required by TS 1.1.7 for the two DSCs listed above. This information was obtained using LGS procedure ST-6-114-360-0, "Independent Spent Fuel Storage Installation (ISFSI) Technical Specification Testing."
Should you have any questions, please contact Mr. John L. Schrage at (630) 657-2821.
Respectfully, Patrick R. Simpson Manager - Licensing
Attachment:
Thermal Performance Assessment Data, Limerick Generating Station, Independent Spent Fuel Storage Installation, 2013 Dry Cask Storage Campaign cc:
NRC Regional Administrator - Region I
Attachment Thermal Performance Assessment Data Limerick Generating Station Independent Spent Fuel Storage Installation 2013 Dry Cask Storage Campaign Dry Storage Canister Number LGS-61BTH1-D-2-027 Horizontal Storage Module Number HSM-043 Maximum Allowable Heat Load 19.40 kW Actual Loaded Heat Load 13.46 kW Calculated Temperature Rise 43.0° F Measured Temperature Rise 19.10 F Dry Storage Canister Number LGS-61 BTH1 -D-2-028 Horizontal Storage Module Number HSM-042 Maximum Allowable Heat Load 19.40 kW Actual Loaded Heat Load 13.70 kW Calculated Temperature Rise 42.0° F Measured Temperature Rise 29.7° F Attachment Thermal Performance Assessment Data Limerick Generating Station Independent Spent Fuel Storage Installation 2013 Dry Cask Storage Campaign Dry Storage Canister Number LGS-61 BTH1-D-2-027 Horizontal Storage Module Number HSM-043 Maximum Allowable Heat Load 19.40 kW Actual Loaded Heat Load 13.46 kW Calculated Temperature Rise 43.0° F Measured Temperature Rise 19.1° F Dry Storage Canister Number LGS-61 BTH1-D-2-028 Horizontal Storage Module Number HSM-042 Maximum Allowable Heat Load 19.40 kW Actual Loaded Heat Load 13.70 kW Calculated Temperature Rise 42.0° F Measured Temperature Rise 29.7° F