PM-81-784, Forwards Monthly Operating Rept for Aug 1981
| ML20010F966 | |
| Person / Time | |
|---|---|
| Site: | Hatch |
| Issue date: | 09/10/1981 |
| From: | Manry M GEORGIA POWER CO. |
| To: | Office of Nuclear Reactor Regulation |
| References | |
| PM-81-784, NUDOCS 8109150167 | |
| Download: ML20010F966 (1) | |
Text
-._
l l
Georgia Power Company Post Office Box 442 Baxley, Georg:a 31513 Te!ephone 912 367-66S6 912 367-7781 b
Edwin 1. Hatch Nuclear I'lant eof OWer
'ty a,
t
,o, September 10, 1981 PM-81-704 s
- o PLANT E.
I. HATCH FO NRC Monthly Operating Report q\\
(4 h
(9
)
Office of Plans and Schedules 5
SEP 141981 >
Directorate of Licensing g
u.a.
imm u w p
United States Nuclear Regulatory Commission Washington, D. C.
20545 Q
- 7
Dear Sir:
E to Per Tech Specs section 6.9.1.6 please find attached the NRC Monthly Operating Report for Hatch Unit 1, Docket #50-321.
s'h]0,]M]i wul-M/ Manff C Plant Manag9 x
CLC/pebc l
s, u 8109150167 810910 PDR ADOCK 05000321 R
W.
~~.
NARRATIVE REPORT UNIT 1 August 3rd 1054 1A reactor feed pump turbine off to repair seal water line August 10th Unit auto scrammed on RPS trip at 1445 August lith Became critical at 0903. Unit auto scrammed due to IRM spike at 2352 l
August 12th Became critical at 0532.
Tied to line at 1829 I
August lith Unit Auto scrammed due to turbine stop valve fast closure at 0123.
Critical at 0619. Unit tied to line at 1300 August 16th Power reduction to perform a Rod Pattern Adjustment at 1900 August 19th Decreased loar' due to Plant Service Water strainers stopping up at 2045 pap OF Bl & 9.L 6 $ $ Q 1.
T.
5 HATCH 1 SAFET1-RELATED MAINTENANCE REQUESTS
[
TO BE REPORTED FOR August 1981 i
i NUMBER DATE COMPLETED DESCRIPTION 80-3925 8-24-81 Route conduit and cable to PSW-To-Air compressors electronic water heater 81-5680 8-09-81 Repair limit switch on outlet isolation valve to D/W pneumatic system. (P70-F005) 80-5461 8-28-81 Perform work for DCR 80-279 (Intake Backfill) 81-1939 6-01-81 Replaced RHR Loop A
Inboatd Injection Valve Motor 81-3489 6-02-81 Rerouted valve air line and relocated support per M.R.
81-5130 8-03-81 Welded stud on disc and remachined to fit yoka Jf RHR S/W Pump 81-5683 8-24-81 Fabricated RHR Service Water pipe support E11-ISH-H701.
Level "E"
Housekeeping 81-5684 8-24-81 Fabricated R'IR Service Water pipe support E11-ISH-H700.
Level "E"
Housekeeping 81-5686 8-24-81 Fabricated RHR Service Water pipe support E11-ISH-H702.
Level "E"
Housekeeping di-4559 8-10-81 Replaced HPCI Steam Line Delta P instrument. (E41-N005) l 81-4611 6-12-81 Replace ball and ball holder assembly on HPCI turbine overspeed trip 81-5468 7-31-81 Repair oil leak on Robert Shaw Diaphragm valve on HPCI overspeed trip 81-5903 8-12-81 Replace diaphragm on HPCI overspeed trip (E41-C002) 81-5904 8-12-81 Remove and inspect inboard bearing cap and bearing on HPCI turbine
f.
l
' ~.
r 81-1498 6-10-81 Replace existing mechanical snubber with PSA a snubber 81-1501 (1L35) 81-1503 t
81-1515 i
81-1517 81-1518 81-1519 81-1595 81-1596
+
l 81-1597 i
81-1598 l
81-1011 8-18-81 Install foam fire sealant around all penetrations
.through gland seal treatment room walls 81-1626 8-22-81 Rebuild PSW pump 1C 81-4482 8-03-81 Repair corroded area on 30" diameter SW piping at intake structure 81-5375 7-22-81 Install new bearings in PSW pump 1C 81-5868 8-20-81 Rebuild 1B PSW check valve (1P41-F311B) 81-2899 5-29-81 Relocate
' local starter R27-S035, from torus to reactor b1dg. 130' elev.
81-5534 8-17-81 Perform P/M on 125V Diesel Battery IC 79-5566 1-06-81 Install modified woodward governor for Diesel 1C.
(1R43-S001C) 81-4048 8-10-81 Install cover over hole in reactor b1dg.
130' elev.
floor (T22) 81-2584 5-28-81 Pull cables to DW/ Torus vent exhaust valve
U DOCKETNO.
UNIT EHUTDOWNS AND POWER REDUCTIONS Imen 1 UNIT N AME -N -OL DATE U. M. Curtis COMPLETED BY
/
REPORT MONTH Aup,ust TELEPilONE 912-367-7851 j'
1 3
E Licensee
,E s;,
j".
Cause & Currective
.3?
3
} YIl No.
Date R
5g o5$
Event y
pO Action to j
H
$E 5
jgg Report #
mO Prevent Recurrence g
j 8
1 l
'81-61 810803 F
11.1 B
5 PM 01 IURBIN toad reduction to repair.1A RFFr seal-aater line i
81-62 810810 F
33.1 A
3 t%
IA XXXXX Rx. Auto Scram on RPS trip 81-63 810811 F
18.6 H
3 1R IA IllSTRU Rx. Auto Scram on IIM spike 81-64 810812 F
30.9 H
5 FM IA IllSTRU Recovery from scram # 81-63 81-65 810814 F
11.6 H
3 1R la VALVEX Rx. Auto Scram due to 'Ibrbine stop valvo fast closure 81-66 810814 F
54.0 H
5 la IR VAINEX Recovery from scram # 81-65 4
l 81-67 810816 S
52.0 B
5
-IM RB CONROD frad Reduction for RodTittern Adjust-nent l'
l 81-68 810819 F
71.3 B
5 tR W4 FIL'IER Power decrease due to stopped up PSW Strainers 2
1 2
3 4
/
F: Forced Renon:
Method:
Exhibit G. Ingructions 5: Scheduled A Equipment'Fallure(Explain) 1.Manust for Preparation of Dats B Maintenance of Test 2 Manual Scram.
Entry Sheets for Licensee C-Refueling 3 Automatic Scram.
Event Report (LER) File (NUREG-D-Regulatory Restriction 4 -Continuations 0161)
E-Operator Training & Ucense Examination 5-Ioad Bedaction 5
F-Administrative 9-Other (Explain)
Exhibit I.Same Source G-Operational Error (Explain)
(9/77)
Il-Other (Explain) 1
[
4 j
w 1
x REFUELING INFORMATION FOR HATCH UNIT 1 Hatch Unit 1 is scheduled to shutdown on 4-2-82, for its next refueling outage.
Startup from that outage is scheduled for 8-20-82.
Description of operation after refueling will require a
Technical Specification change concerning core thermal hydraulic limits.
No particular date for submitting proposed licensing action and supporting information has been named.
- However, the latest date for submittal will be 5-20-82.
There are 560 fuel assemblies in the core and none presently in the spent fuel storage pool.
The present licensed spent fuel pool storage capacity is 3021 fuel assemblies.
No requests for an increase in licensed storage capacity are anticipated in the near future.
The projected date of the last refueling that can be discharged to the spent fuel pool assuming the present licensed capacity is 1996.
5
GeorgiaPo OPEPHTIltG OHT6 FEPOPY
~~ -
~ ~-- -
DOCKET H0. 50-321~ ~ ~ ~ ~ ~
'DATE 69;10-01
~
~
C6HPCETED~BFCHRI'S M.
cVRTIS
- - - - - ~ -
~
~^-
T ELEPHONE ( 912 F367;7 791 x 267 OPER4 TING $ Milis N
- Hotes
~
- 1. Udit~Hane E.IlHatch Huclear ~ Plant Unit 1 8.
R e p o r EIn'g" PiF T5~dT 6 8 -0 l'
--- 3. L i c e n s e d Thernal ~PoweF (MWt): 2436 4.
Ha~neplate ~ Rating 1 Cross MWe): 809.3
- - - ~ ~ ~ ~ ~ -
~
- s. Design ETeEtr ical Riti6fTIIe't HUETi 777T3 6.
Hexinun Dip e 6da bTi C a picil'y~~-( C Fo s s~ HW e li~ 7 9 613 ' - *
~
- (*i+*******i++*****ie***************************T3**
7.
H~a x i n urT D e p e n ds til~e C a p d c i t y-~( H e t H W e ) : ~7 5 6~: 0 - ~ ~~*
- ca p a c i t y Rit i ng s TI Ee h s Humber 3 Through /7 bence Last Meport, Give Reasonsi 8.
If changes occur in v.
Power Lavel To which Restricted it any (Net HFe > ;
t oTRii s o n s Fo r ~ R is' t F Fc t Io n s; ITT T--~~~~~~~~~-
. ~.. ---
_ _... _ ". ~ -This Month ~
Tr--;to;Date c u nill a tWe
~
~ ~ ~ ~~ ~
~ ~ ~ - - ~ ~ -~
~
~ ' ~~ - ~ ~ - - ~ ~ ~~~
~
.._. ~.
11.
ilo u r s in R e p d r t Tn f F E FT o'd 744 5871 496/9 I r ifunber'Of HouFs Recctor Was"CritTcal' 715.1 3220l3 36732T3 177 R e a c t o r-~ R e s e r v'e ' S h u t do w n H ou r s ~ ~ ~
0 ~10
'00 070
- 14. HoiiFi CeneFat6r On-Lini 63077 zB28.3 34277 9
-'~r5-U 6 T t~ R e s e r v e ~ Sh u t d o w n H o' r s--
~ ~ ~
~~
0.0 0 '; 0 0 ~. 0 u
IT Cr6'ss Thernal Energy Genera t ed ( MUH )
~ - ~ ~ --- '~ ~-'
~1503264 5738119
/f541001
- 17. Gr o sFElic tFTcsI 'EneFgf CFnVra ted C HUlFI 4E7776 1154300 z.511i4 0 3 0 465622 l'754091 z2006569 1B-Het ElectFTdel En e rgy~ C ener~a te d ( NWH)~ ~ ~ - ~ ~ ~
91J5-4875 6970 i 97UnTL Se r vi ce" Fa c t o r ~ ' '
9T s 48.s 69.o zo. Un6t NTilib' silty"FictbF-
-~- 2' f U n~i t C a p o~c~i t~y F a c t o F~( U s i n g ~ M D C ~ N e t F ~' ~ ~~~ ~ ~ ~ -
~ ~ ~~~~- -82~T 3977 58 5
-- 2'27 Un it C a p a c i t y ~ F d c t 6F~I U s i n g" D ER H e t ) -- ~ -~ ~
~~ ~-
C OT 5 38T7 s77o
- 23. Unit FETc FrT ~ O u fife ~Rit e s.s 17.1 19.9 74 ~S hiit~d'6Eiii S c hid ul id ~ 0ili'r H e it-~6 ~ H o n t h i ~( Ty p e, D a t eT a~nd D u fa~ t i o n o f EialD
- 25. If Shut Down At Eiid~0FRepor t Per66d, Esti nate'd Date oFS t ar tup :
~
~
- 26. Units I R T ii t'S tMus T P r i or to C o n n e r c i a l O p e F a tT5 n Ti Forecast AEhieved y
!~ NIT I AL CRITIC All TY IKItIAL ELECTRIC 1TY c 0hliUTC fiir UPERh T Io M e_.-_
N9f((h sammm. ew e
-ggi.Ww.-=ee mm-'
e_e.m.-N wona g--wee-.
w w.m
-e.
m-e..-e
-.e a.u.g..esy
==um.--e w
-.m-
r l
J l
Jll j
j1
]
ll llllIl l
j, o.
P.
a i
ob roeG
~
~
~
~ -
~
~
~
~ -
~ -
~
~-
~
~
~
7
~
~
3_
~
7 L
e 7
0 E
7 2
V
~
E
~
L c
S I 1 F
~
E,
~
~ ~
T 2 W
~ ~
F7 4 4.
437 U7 O
C -
P
~
7 67C29 060
~
20S' A
~
555545 I
0 Y
907961 55 CM3 L
57635777. 777'.77
~
I
~ ~
71 I 2 D
~
t i
~
- ~
~
- - F 1 e
6 m
L o?H 9 E
~
~
m
~
t E
S6 C(
C
~
V A
E EYE F
~
~
h L
DT EN E
H A O
V
~
F DDH A
~
~
E T
~
U E
T E F
C LE Y
7 8 9'c 1 2345678 701 O
r EL
~
222222222733 O
PT A
1 1 1
^
T D
M D
~ -
~
~
I O
~
^
~
N C
~ -
~
U e.
~
Y
~
L L_
~
I E_
A
~
V_
D
~ - -
E_
E L_
G 4
R_
F E_
~
U)
E V
U A
P
'08s83606 949 0
70'51
~
558 4
Y 56645454551 1 L
776777 7774 -
41 5 6
I T
D.
c E.
G _.
A_
gR
~
E V
A.
1 44 3
6 Y
1 234 567 89o.
U1 g
1g I
1 1
A D
1ll ll l
ll,jlllllll llll l1lllll
,