PLA-7321, Completion of Actions Required by NRC Order EA-12-051, Reliable Spent Fuel Pool Instrumentation PLA-732 1

From kanterella
(Redirected from PLA-7321)
Jump to navigation Jump to search
Completion of Actions Required by NRC Order EA-12-051, Reliable Spent Fuel Pool Instrumentation PLA-732 1
ML15211A378
Person / Time
Site: Susquehanna  Talen Energy icon.png
Issue date: 07/02/2015
From: Rausch T
Susquehanna, Talen Energy
To:
Document Control Desk, Office of Nuclear Reactor Regulation
Shared Package
ML15211A375 List:
References
EA-12-051, PLA-7321
Download: ML15211A378 (2)


Text

Security-Related Information - Withhold Under 10 CFR 2.390 Susquehanna Nuclear, LLC President and Chief Nuclear Officer 769 Salem Boulevard JUL 02 201O5 Berwlck, PA 18603 Tel. 570.542.3445 Fax 570.542.1504 TALENd' ENERGY Timothy.Rausch@talenenergy.com U. S. Nuclear Regulatory Commission 10 CFR 2.202 ATTN: Document Control Desk Washington, DC 20555-0001 SUSQUEHANNA STEAM ELECTRIC STATION COMPLETION OF ACTIONS REQUIRED BY NRC ORDER EA-12-051, "RELIABLE SPENT FUEL POOL INSTRUMENTATION" Docket No. 50-387 PLA-732 1 and No. 50-388

References:

1. NRC OrderNwnber EA OS1, Order Modify'ing Licenses with Regard to Requirementsfor Reliable Spent Fuel Pool Instrumentation, datedMarch 12, 2012.
2. PPL Letter (PLA -6980,) titled, "OverallIntegrated Plan in Response to March 12, 2012 C~ommission Order to Modify Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (NRC OrderLA OS)), '"datedFebruary28, 2013.
3. NRC Letter titled, "Request for Additional Information Regarding Overall IntegratedPlanfor Reliable Spent Fuel Pool Instrumentation (OrderNumber EA-12-051,) (TAC NOS. MF0890 AND MF0891), "'datedJune 17, 2013.
4. PPL Letter (PLA -7073) "PPLSusquehanna'sFirst Six-Month Status Report in Response to March 12, 2012 Commission OrderModifying Licenses with Regard to Reliable Spent FuelPool Instrumentation (OrderNumlber LA OS51), "datedlAugust 26, 2013.
5. PPL Letter ('PLA-7138,) "'PPLSusquehanna'sSecond Six-Month Status Report in Response to March 12, 2012 C'omnmission Order Mod~jin]~lgLicenses wsith Regard to Reliable Spent Fuel Pool Instrumentation (OrderNumber EA 051), '"datedFebruary27, 2014.
6. PPL Letter (PLA- 7222) "PPL Susquehanna's Thir'dSix-Month Status Repor~t in Response to March 12, 2012 C'ommission OrderModifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (OrderNumber LA- 12-051), '"dated August 27, 2014.
7. PPL Letter (PLA-7296,) "'PPLSusquehanna's FourthSix-Month Status Report in Response to March 12, 2012 C'omnmission OrderModifying Licenses with Regard To Reliable Spent FuelPool Level Instrumentation (NRC OrderEA 051,), ""datedFebruary25, 20)5.

On March 12, 2012, the Nuclear Regulatory Commission (NRC) issued Order EA- 12-051, "Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation," to PPL Susquehanna, LLC (now known as Susquehanna Nuclear, LLC). This Order was effective immediately and directed Susquehanna Units 1 and 2 to install reliable spent fuel pool instrumentation as outlined in Attachment 2 of the Order. This letter, along with its k I' "

Security-Related Information - Withhold Under 10 CFR 2.390 Upon Removal of the Enclosures, this Letter is Decontrolled

/ oo!

Document Control Desk PLA-7321 enclosures, provides the notification required by § IV.C.3 of the Order that full compliance with the requirements described in Attachment 2 of the Order has been achieved for Susquehanna Units 1 and 2.

The enclosures to this letter contain security related information, and Susquehanna Nuclear, LLC requests that these enclosures be withheld from public disclosure in accordance with 10 CFR 2.390(d)(1).

This letter contains no new regulatory commitments.

If you have any questions regarding this report, please contact Mr. Jeffery N. Grisewood, Manager - Nuclear Regulatory Affairs, at (570) 542-1330.

I declare under penalty of perjury that the foregoing is true and correct.

Executed on: -1(4K President and Chief Nuclear Officer

Enclosures:

1. Compliance with Order EA- 12-05 1
2. Responses to NRC Requests for Additional Information
3. Bridging Document Copy: NRC Region I Mr. J. E. Greives, NRC Sr. Resident Inspector Mr. J. A. Whited, NRC Project Manager Mr. B. R. Fuller, PA DEP/BRP