PLA-6211, Transmittal of Extended Power Update Application Regarding Steam Dryer Request for Meeting with NRC Staff

From kanterella
(Redirected from PLA-6211)
Jump to navigation Jump to search
Transmittal of Extended Power Update Application Regarding Steam Dryer Request for Meeting with NRC Staff
ML071510174
Person / Time
Site: Susquehanna  Talen Energy icon.png
Issue date: 05/22/2007
From: Mckinney B
Susquehanna
To:
Document Control Desk, NRC/NRR/ADRO
References
PLA-6211
Download: ML071510174 (3)


Text

rI Brutt T. McKInney Sr. Vice President & Chief Nuclear Officer MAY 2 2 2007 PPL Susquehanna, LLC 769 Salem Boulevard Berwick, PA 18603 Tel. 570.542.3149 Fax 570.542.1504 btmckinney@ppIweb.com A

p

  • Ie:

pGoa-P P 14%

U. S. Nuclear Regulatory Commission Attn: Document Control Desk Mail Stop OP1-17 Washington, DC 20555 SUSQUEHANNA STEAM ELECTRIC STATION PROPOSED LICENSE AMENDMENT NO. 285 FOR UNIT 1 OPERATING LICENSE NO. NPF-14 AND PROPOSED LICENSE AMENDMENT NO. 253 FOR UNIT 2 OPERATING LICENSE NO. NPF-22 EXTENDED POWER UPDATE APPLICATION REGARDING STEAM DRYER REQUEST FOR MEETING WITH NRC STAFF PLA-6211 Docket Nos. 50-387 and 50-388 Reference. 1)

PPL Letter PLA-6076, B. T. McKinney (PPL) to USNRC, "Proposed License Amendment Numbers 285for Unit I Operating License No. NPF-14 and 253for Unit 2 Operating License No. NPF-22 Constant Pressure Power Uprate, "dated October 11, 2006.

2) PPL Letter PLA-6138, B. T. McKinney (PPL) to USNRC, "Proposed License Amendment Numbers 285for Unit I Operating License No. NPF-14 and 253 for Unit 2 Operating License No. NPF-22 Constant Pressure Power Uprate - Supplement,"

dated December 4, 2006.

3) PPL Letter PLA-6146, B. T. McKinney (PPL) to USNRC, "Proposed License Amendment No. 285for Unit I Operating License No. NPF-14 and Proposed License Amendment No. 253for Unit 2 Operating License No. NPF-22 Constant Pressure Power Uprate -

Second Supplement, "dated December 26, 2006.

4) PPL Letter PLA-6176, B. T. McKinney (PPL) to USNRC, "Proposed License Amendment No. 285for Unit I Operating License No. NPF-14 and Proposed License Amendment No. 253for Unit 2 Operating License No. NPF-22 Extended Power Update Application Regarding Steam Dryer and Flow Effects Requestfor Additional Information Responses," dated April 27, 2007.

Pursuant to 10 CFR 50.90, PPL Susquehanna LLC (PPL) requested in Reference 1 approval of amendments to the Susquehanna Steam Electric Station (SSES) Unit 1 and Unit 2 Operating Licenses (OLs) and Technical Specifications (TS) to increase the maximum power level authorized from 3489 megawatts thermal (MWt) to 3952 MWt, an approximate 13% increase in thermal power. The proposed Constant Pressure Power Uprate (CPPU) represents an increase of approximately 20% above the Original Licensed Thermal Power (OLTP).

The purpose of this letter is to provide GE Draft Dryer Presentation material to the NRC to facilitate NRC determination of proprietary content.

+0)01 Document Control Desk PLA-6211 The purpose of the meeting is as follows:

  • Present the steam dryer instrumentation plan with locations and rational for type of instruments and their locations,

" Discussion of the fabrication detail improvements and why they are expected to improve stress intensity margins, Discuss strategy for developing start-up limit curves and availability schedule Since the first two items above will involve proprietary information, Attachment I contains the proprietary GE Draft Dryer Presentation material. A non-proprietary version of Attachment I is provided in Attachment 2. The affidavit supporting this request is provided in Attachment 3. contains information that General Electric Company considers proprietary.

General Electric Company requests that the proprietary information be withheld from public disclosure in accordance with 10 CFR 2.390 (a) 4 and 9.17 (a) 4.

References 2-4 contain the relevant PPL and NRC dryer correspondence.

Meeting attendees are expected to include:

PPL - John Krais, John Bartos, Kevin Browning, Mike Gorski, Tom Oldenhage, Mike Crowthers General Electric - Dan Pappone, Mike Bridges, Larry King, Craig Nichols If you have any questions or require additional information, please contact Mr. Michael H. Crowthers at (610) 774-7766.

B. T. McKinney

-3 Document Control Desk PLA-6211 : Proprietary Version of the GE Draft Dryer Presentation : Non-Proprietary Version of the GE Draft Dryer Presentation : General Electric Company Affidavit Copy:

NRC Region I Mr. A. J. Blarney, NRC Sr. Resident Inspector Mr. R. V. Guzman, NRC Sr. Project Manager Mr. R. R. Janati, DEP/BR