PLA-6149, Comment (9) of B. T. Mckinney on Behalf of PPL Susquehanna, LLC on Draft Regulatory Guides DG-1133 and DG-1134

From kanterella
Jump to navigation Jump to search
Comment (9) of B. T. Mckinney on Behalf of PPL Susquehanna, LLC on Draft Regulatory Guides DG-1133 and DG-1134
ML070110427
Person / Time
Site: Susquehanna  Talen Energy icon.png
Issue date: 01/09/2007
From: Mckinney B
Susquehanna
To:
NRC/ADM/DAS/RDB, NRC/SECY
References
71FR62947 00009, DG-1133, DG-1134, PLA-6149, RIN 3150-AH48
Download: ML070110427 (5)


Text

Bdrtt T. McKinney PPL Susquehanna, LLC PPg Sr. Vice President & Chief Nuclear Officer 769 Salem Boulevard Berwick, PA 18603 Tel. 570.542.3149 Fax 570.542.1504 btmcklnney@pplweb.com

,AH09 tOOT

-r Tn CD. C-Secretary, U. S. Nuclear Regulatory Commission Washington, DC 20555-0001 Attn: Rulemakings and Adjudicating Staff Ul)

SUSQUEHANNA STEAM ELECTRIC STATION INCORPORATION BY REFERENCE OF AMERICAN SOCIETY OF MECHANICAL ENGINEERS BOILER AND PRESSURE VESSEL CODE CASES CONTAINED IN DRAFT REG. GUIDES DG-1133 AND DG-1134 (RIN 3150 AH80) Docket Nos. 50-387 PLA-6149 and 50-388 The following are PPL Susquehanna, LLC's (PPL) comments on Draft Regulatory Guides DG- 1133 "Proposed Rev 34 to Regulatory Guide RG 1.84, 'Design, Fabrication and Materials Code Case Acceptability, ASME Section III' and DG-1 134 "Proposed Rev 15 to RG 1.84, 'Inservice Inspection Code Case Acceptability, ASME Section XI, Division 1.'"

DG-I133 Code Case N-659 This comment deals specifically with the proposed rewriting of paragraphs (b) and (d) of Code Case N-659.

The NRC Staff has concerns with the "non blind" ASME Section V approach currently allowed by Code Case N-659. The NRC's desired methodology would be an Appendix VIII type of qualification. However, re-writing a performance based methodology as stated in the proposed changes could introduce new problems or challenges that would not surface until the actual qualification was attempted. Some examples of potential problems are:

" The proposed changes do not specifically address grading unit lengths as Appendix VIII does.

" Introducing a 2% deep flaw in thin materials may be a challenge.

o Thickness/diameter ranges are not addressed f &

6 C), S ,:_:

Lz-e-& :-U/V rc-7-ý

/2-ý =-- /ý 2ý5

Document Control Desk PLA-6149 While agreeing with the use of a Section XI performance demonstration methodology, PPL would prefer to use the existing Performance Demonstration Initiative (PDI) process that is already administered by the EPRI NDE Center and performing a supplemental blind qualification to a previously approved procedure by adding a minimum of three different construction-type flaws. The NDE Center has protocol in place for adrninistering procedure/personnel qualifications and EPRI's implementation procedures have been accepted by the NRC staff to be in compliance with Appendix VIII and

°10 CFR 50.55a. The detection criteria for the additional three flaws should be three (100%). Using.the'existingEPRI PDI program-would remove the uncertainties associated with the proposed criteria.

DG-1134 Code Case N-460 This comment deals with the last sentence which states - "Thus, the NRC proposes to condition the use of Code Case N-460 in the final guide such that the Code Case can only be applied When.performing inservice examinations in accordance with a Section XI inseiVice insp-eefioffSfrogram."

While ;PPL agrees that Code Case N-460 should not be used in conjunction withCode Case N-659;,the condiitionVacIeptaniIe proposed above is considered unnecessary.

Code iCases N-659 and N-659-1 :already require that the ultrasonic examination area be accesible and "include 100% of the volume of the entireýweld, plus 1/2:in.-(13mm) of.

each side ofthe welds."' Similar provisions are'contained -in Code Case N-713.

Though the actual wording of the proposed condition is not specified, the limitation to "inservice" examinations noted above will be burdensome during repair and replacement of ýxisting c omlponents because of the preservice examination requirements contained in IWA-4530. The inservice only conditional acceptance would prohibit the use of Code Case N-460 for preservice examination of repairs to existing components and in-kind replacements, neither of which would typically affect access. Though the extent is unknown, the end result would be additional, otherwise unneeded, relief requests.

Document Control Desk PLA-6149 Code Case N-504-2

1) Applicability of this code case is only up to the 1995 Edition. After 1995, the reference paragraphs in the Code have changed and administratively the Code Case cannot be used. Code'Case N-504-3 has corrected these issues. Code Case N-504-3 shoiild be approved for use in Rev. 15 of Reg. Guide 1.147 instead of N-504-2.
2) The limitation on this Code Case is unchanged from'Revision 14 of Regulatory Guide 1.147. However, the limitation requires the use of Non-Mandatory Appendix Q and points the user to the 'estools' website. Appendix Q is now published and is available in the 2004 Edition with the 2005 Addenda, and later editions and addenda, of Section XI. The limitation should point users to the 2005 Addenda of Section XI, not the 'cstools' website.

Alternatively, we recommend the NRC expedite the review and approval of Code Case N-504-3 (pfiblished in supplement 5 of the 2004 edition) with no limitations. -During the evaluation of Code Cases for Revision 14 of the'Reg. Guide, the NRC identified four concerns with Code Case N-504-2 that were addressed by the ASME in Code Case N-504-3 and-Non-Mandatory Appendix Q. Thus, Code Case N-504-3 addresses the concerns the NRC has with Code Case N-504-2.

Code Case N-517-1 The limitation on this Code Case is unchanged from Revision 14 of Regulatory Guide 1.147. The limitation should be removed and this Code Case added to the list of acceptable Section XI Code Cases. This limitation was to be addressed by Subcommittee XI action BC04-265* During discussions at the ASME Subcommittee XM meetings in November of 2005, as well as a number of prior telephone conferences, the NRC representatives and the rest of the committee agreed this limitation wais no longer needed.

The original NRC concerns were with substandard and fraudulent material. The NRC representatives to the committee expressed this issue is no longer a concern. Therefore, this action, BC04-265, was revised to simply incorporate Code Case N-517-1 into the Code. That action has now passed the standards committee with the support of the NRC.

Document Control Desk PLA-6149 Code Case N-532-3 NRC has placed a condition on this Code Case, which requires the Outage Activity Report to be submitted within 90 days after each refuel outage. Code Case N-532-4 contains the requirement to submit'the OAR within 90 days after each refuel outage.

Code Case N-532-4 should be used in draft Rev. 15 of RG 1.147 instead of Code Case N-532-3 in order to resolve the 90 day submittal after each refuel outage conditional acceptance issue.

Please contact Mr. Richard Tombasco at (610) 774-7220 if you have any questions concerning this letter.

Sincerely, c.*- NRC RegionI Mr. R. Guzman, NRC Project Manager Mr. R. Janati, DEP/BRP Mr. C. Welch, NRC Sr. Resident Inspector

c.\temp\GW)00003.TMP Page I1:1 c:\temp\GW}00003.TMP Page 1 Mail Envelope Properties (45A3E6E0.809: 8: 30729)

Subject:

FW: PLA-6149 (signed copy)

Creation Date 01/09/2007 2:02:43 PM From: "Bollinger, Elisabeth C" <ebollinger@pplweb.com>

Created By: ebollinger@p122web.com Recipients nrc.gov TWGWPO02.HQGWDOO1 SECY (SECY) pplweb.com ratombasco CC (Richard A Tombasco)

Post Office Route TWGWPO02.HQGWDOO1 nrc.gov pplweb.com Files Size Date & Time MESSAGE 863 01/09/2007 2:02:43 PM TEXT.htm 1788 pla6149.pdf 232827 Mime.822 323613 Options Expiration Date: None Priority: Standard ReplyRequested: No Return Notification: None Concealed

Subject:

No Security: Standard