PLA-5679, Submittal of Fire Protection Review Report, Revision 13

From kanterella
Jump to navigation Jump to search
Submittal of Fire Protection Review Report, Revision 13
ML032900124
Person / Time
Site: Susquehanna  Talen Energy icon.png
Issue date: 10/09/2003
From: Shriver B
Susquehanna
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
PLA-5679
Download: ML032900124 (13)


Text

Bryce L Shrher Senior Vice President and Chief Nuclear Officer PPL Susquehanna, LLC 769 Salem Boulevard Bervick, PA 18603 Tel. 570.542.3120 Fax 570.542.1504 blshriver@pplweb.com OCT 0 9 2003 pp TM U. S. Nuclear Regulatory Commission Attn: Document Control Desk Mail Stop OPI-17 Washington, DC 20555 SUSQUEHANNA STEAM ELECTRIC STATION SUBMITTAL OF FIRE PROTECTION REVIEW REPORT REVISION 13 PLA-5679 Docket Nos. 50-387 and 50-388 The purpose of this letter is to submit Revision 13 of the Fire Protection Review Report (FPRR). A summary of the revisions made in Revision 13 of the FPRR is provided in of this letter.

Revision 13 is being submitted on CD-ROM in accordance with NRC Regulatory Issue Summary 2001-05 titled "Guidance on Submitting Document to the NRC by Electronic Information Exchange or on CD-ROM." The CD-ROM for the FPRR contains a complete copy of the FPRR. to this letter provides the steps to be taken to read the CD-ROM.

The following information is provided to assist in reading the CD-ROM:

Format: TIFF Version: group 4 File Name: #.tif Contact Individual: Mark R. Breiner, Mail Stop GENPL4 Contact Individual's Phone Number: 610-774-7691 Contact Individual's Address: Two North Ninth Street, Allentown, PA 18101 Contact Individual's E-Mail Address: mrbreiner@pplweb.com Please contact Mr. C. T. Coddington at 610-774-4019 if there are any questions concerning this submittal.

Sincerely, Z

B.

ver

_Clp Document Control Desk PLA-5679 Attachments (2) / Enclosure with one (1) CD-ROM Copy: - Summary of FPRR, Rev. 13 Changes - Using SSES FPRR Revision 13 CD-ROM CD-ROM: (1) FPRR Rev. 13 Copy: NRC Region I Mr. R. V. Guzman, NRC Project Manager Mr. S. Hansell, NRC Sr. Resident Inspector Mr. R. Janati, DEPIBRP w/o CD-ROM w/a CD-ROM w/o CD-ROM w/o CD-ROM to PLA-5679 Summary of FPRR Rev. 13 Changes to PLA-5679 Page 1 of 2 FPRR Revision 13 - Summary Section Table Figure Description of Change 3.3 Revised to reflect the installation of a passive backup keepfill system to maintain the source of keepfill water for the existing ECCS and RCIC keepfill systems in each unit.

Revised to add a discussion on SRV depressurization capability.

3.3-1 Revised to reflect the installation of a passive backup keepfill system to maintain the source of keepfill water for the existing ECCS and RCIC keepfill systems in each unit.

Revised to reflect use of operator actions from panel 1C628 in the upper relay room in the event of the loss of the ability to operate Unit 1 from the control room due to the loss of the ADS automatic control logic power supply.

3.3-2 Revised to reflect use of operator actions from panel 1C628 in the upper relay room in the event of the loss of the ability to operate Unit 1 from the control room due to the loss of the ADS automatic control logic power supply.

3.3-3 Revised to reflect use of operator actions from panel 1C628 in the upper relay room in the event of the loss of the ability to operate Unit 1 from the control room due to the loss of the ADS automatic control logic power supply.

4.10 Revised to clarify the SSES position on the minimization of plastic material at SSES and provides clarification and consistency within the FPRR regarding the description of plastics, cable insulation, and ceiling tiles used in the facility.

to PLA-5679 Page 2 of 2 Section Table Figure c Descriptionof Change 5.0-1 Revised to clarify the SSES position on the minimization of plastic material at SSES and provides clarification and consistency within the FPRR regarding the description of plastics, cable insulation, and ceiling tiles used in the facility.

Revised to correct the description of the cable spreading room fire barriers.

Revised t o indicate that with the exception of the cable types identified in paragraph D.2.c, all scheduled cable types used at SSES have been qualified to the flame test requirements of IEEE 383-1974.

5.0-2 Revised to clarify that changes can be made based on the Fire Protection Program License Condition and not all separation issues need to be sent to the NRC as deviation requests.

6.2 Revised to address the use of key-lock switches in the upper relay room.

Revised to reflect the relocation of Instrument Rack 1C057 from Fire Zone 1-6D to 1-6C.

Revised to reflect replacement of a limited quantity of non-combustible cement fiber fill boards in the Unit 2 Cooling Tower with PVC film fill material.

to PLA-5679 Using SSES FPRR Revision 13 CD ROM to PLA-5679 Page 1 of 7 Using SSES FPRR Revision 13 CD ROM If a version of MaxCD'm older than version 3.2.7 is installed on your PC, it will not allow you to view this CD. Viewing this CD requires installation of MaxCDrm for FileNet, Version 3.2.7. Instructions for installing MaxCD' for FileNet are provided below.

CD Contents This CD contains a set of images containing all the pages of the current revision of the Fire Protection Review Report (FPRR). The images labeled with unique document ID's are assigned alphanumerically as Text and Tables. Drawings were scanned into the document as part of the section to which they belong. The order of the images does not correspond to the ordering of the pages in the FPRR.

The CD also contains a Microsoft Word copy of the Table of Contents to facilitate word searching using that application's "Find" function.

Reading the FPRR In order to "read" the FPRR; a search engine must be used.

This CD contains a royalty-free search engine coupled with a "viewer."

This "viewer" needs to be installed on a PC to facilitate "reading" of this electronic copy of the FPRR.

The images are saved in G4 TIFF format, and can be read by any program capable of displaying that format. There is no identification information stored in the image files (or in the file name) other than that contained in the displayed image itself. The image indexing information is stored in a Microsoft Accessm database contained on the CD.

If the user of this CD prefers, the data may be read from that database without using the included viewer.

Reader Installation As few other applications as possible should be running when CDSetup is executed.

There is one executable file on this CD, named CDSetup.exe. Executing this file will install the MaxCDTm reader on your PC.

After the setup program for MaxCDTm is completed, the user will be asked to reboot the PC to complete program installation in the Windows registry. Once this reboot has been accomplished, MaxCD' can be run to view the contents of the CD.

to PLA-5679 Page 2 of 7 "Executini!" Basic Reader Sorts The MaxCDrm reader is started from the START-Programs-MaxCD for FileNet -

Reader selection in Windows.

When started, the database for the index information will be read and a basic skeleton "data tree" outline of the data on the CD will be presented on the left hand side of the program window (See Screen Image Below).

ER S12344A.1 E

30124Ad

+,;--s.msj

.V e

Thdwgs-ffl@512344 A_

A

'4 Above this skeleton are two pull-down boxes containing available sort criteria for the images (Contents, FPRR, TheDwgs).

to PLA-5679 Page 3 of 7 The "Contents" sort contains the List of Effective Pages (LEP) and Table of Contents for the FPRR. To execute this sort, start by making the selections "FSAR.Type" and

'Section' in the "drop-down" menu windows. Then left-click on the "+" symbol to the left of the blue-green octagonal symbol on the data-tree "Contents" sort. At this point, a bar graph loading indicator will signal that the database is being searched and loaded (See Screen Image Below).

I ViR MWWREEMMU.15ME xi to PLA-5679 Page 4 of 7 The "FPRR" sort contains the Text, Tables, Table of Contents, and List of Effective Pages of the FPRR. To execute this sort, start by making the selections "FSAR.Type" and 'Section' in the "drop-down" menu windows. Then left-click on the "+" symbol to the left of the blue-green octagonal symbol on the data-tree "FPRR" sort. At this point, a bar graph loading indicator will signal that the database is being searched and loaded (See Screen Image Below).

Maqw-

--



I

=

W El w3rpa"

&FART TE-TE

_ ki eo.n I

i~~b TEXT LEP 23Pagm

-... ~~TEXT LEP 2D ag

~jTEXT TC2Pagn

~

TETTOC 2 Pame Il T.~EXT TC2P.O B-.

1-BLE3i11 Pp TABE 12-1 22 i Pag I-~TAE.3ia 3 2 Pages

-jjTABLE 32 13 1Par TABL 3-3 13 IPope IA TABLE IS4 13 1Pape B Ah TwOwgs Ea 0FB340Aj i

-~

NdFPR*acd~

F_

When loading is complete, the tree view will show the FPRR, Table of Contents, the List of Effective Pages, and the contents of the FPRR sorted primarily by Table and Text.

to PLA-5679 Page 5 of 7 The "TheDwgs" sort contains images of all the drawings referenced in Section 8.0 of the FPRR. To execute this sort, start by making the selections "PPLDraw" and "PPL_Sheet" in the "drop-down" menu windows. Then left-click on the "+" symbol to the left of the blue-green octagonal symbol on the data-tree "TheDwgs" sort. At this point, a bar graph loading indicator will signal that the database is being searched and loaded (See Screen Image Below).

R1 Z11.1:

I-I,,~~~~~~~~~

.. =.

i TEX.

.7; T.

".g S

v....

0 _66

` -d is At7_ Fr S Tok. 1 >

mffQ U*

7: j x, '

~

]

-qaw

,,'t,

<, *,,,, t- _

~

t

_ Jo i_.

li. ~

~

~ ~ ~ ~ ~ ~ _

I.

Ey-~~

'aid Pi

s B*t



Dc1t



U-

n7LiIi1 I

I TXT LEP 23 Pags*

ETT LEP WaPaa TEKT ICC 2 Pages TMT TOC 2 Paqu TM T C 2 Paw A ~ ~ ~ !)

~TA mBfE122.112 1 Pape TABE U3 1 2 ag TABLE 3l3.3 1Pw

  • TABLE l34 23 1Pqge I

i 2 S 9 I Page jJE2I5S49 2 PW

~ ~E20590 I Page

~~~E20M 2 1Pape V

Z -;, L 

I.,



., ' I, 2  -

1I I

-,"

4

-

-



-

-

1 i

I 77777~~~~~~~~~~

7~L-77 I

W he tloa i if. co.mpS¢. leteLr,.........

the

- -w' I4,, ~

7~.......

L 177-g dit W S~.

77:3M;!

When loading is complete, the tree view will show the FPRR List of Effective Pages, Table of Contents, the contents of the FPRR sorted primarily by Table and Text and a listing of drawing arrange by drawing number as referenced in the FPRR.

to PLA-5679 Page 6 of 7 Viewing Imagtes To view any item, double-click on the item and it will be displayed in the view window.

If the document selected is a multi-page image, thumbnails of the images in the file will be placed on the far right side of the view window for easier page selection.

OM To page through a multiple page item use "Ctrl N" to page down and "Ctrl P" to page to the previously displayed page. Other "Quick Keys" are listed below.

to PLA-5679 Page 7 of 7 Ouick Keys Ctrl+T Thumbnails on/off Ctrl+C Copy Ctrl+G Gray Scale Ctrl+O Color Ctrl+R Rotate Right Ctrl+L Rotate Left Ctrl+D Rotate Document Ctrl+N Next Page Ctrl+P Previous Page Ctrl+F Flip Ctrl+Z Zoom F5 Refresh Tree View