PLA-2500, Monthly Operating Repts for June 1985
| ML20135B273 | |
| Person / Time | |
|---|---|
| Site: | Susquehanna |
| Issue date: | 06/30/1985 |
| From: | Keiser H, Kuczynski L PENNSYLVANIA POWER & LIGHT CO. |
| To: | Beebee M NRC OFFICE OF RESOURCE MANAGEMENT (ORM) |
| References | |
| PLA-2500, NUDOCS 8509100500 | |
| Download: ML20135B273 (9) | |
Text
___ _.
[^
g>
AVERAGE DAILY UNIT POWER LEVEL
)\\
1
\\ 3 DOCKET NO.
50-387
)
r/j L7
" 4' One UNIT 0
DATE -July 3, 1985 s
gg gi COMPLETED BY L.A. Kuczynski TELEPHONE (717)S42-3759 MONT11 June, 1985 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)
(MWe Net) 0 1
37 588 2
0 33 590 0
846 3
g, 4
0 813
,0 5
0 804 21 6
0 1004 22 0
7 23 1013 8
0 24 1024 9
0 1031 10 0
26 1034 11 0
27 1035 12 30 23 1040 13 352 855 29 14 464 1018 30 33 558 3g 16 640 INSTRUCTIONS On this format list the average daily unit power level in MWe-Net for each day in the reporting month. Compute to the nearest whole megawatt.
l (9/77) 8509100500 850630
^
I hM D
{
g@ N i
+
2 n..,
y y
y u-W
_ _T _T_~_._
3 tTL.
C#J OPERATING DATA REPORT O
DOCKET NO.
50-387 D
M DATE July 3,1985 NIC cg?
COMPLETED BY L.A. Kuczynski TELEPHONE _(717) S42-3759 OPERATING STATUS Unit 1 Susauehanna Steam Electric Station N"
- 1. Unit Name:
- 2. Reporting Period:
June, 1985
- 3. Licensed Thermal Power IMWt1:
3,293
- 4. Nameplate Rating (Gross MWe):
1,152
- 5. Design Electrical Rating (Net MWe): 1,065 1.068
- 6. Maximum Dependable Capacity (Gross MWe):
1,032
- 7. Maximum Dependable Capacity (Net MWe):
- 8. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report. Gise Reasons:
- 9. Power Level To which Restricted. If Any (Net MWe):
- 10. Reasons For Restrictions. If Any:
None This Month Yr. to Date Cumulatise
- 11. Hours in Reporting Period 720 4,343 18,096
- 12. Number Of Hours Reactor Was Critical 508.5 1,404.5 11.797.2
- 13. Reactor Reserve Shutdown Hours 0
41.8 513.2
- 14. Hours Generator On-Line 440.6 1,324.5 11,471.4
- 15. Unit Resene Shutdown Hours 0
0 0
- 16. Gross Thermal Energy Generated (MWH) 1,149,907 3.679.450 34.308.438
- 17. Gross Electrical Energy Generated (MWH) 368,670 1,191,820 11,182,350
- 18. Net Electrical Energy Generated (MWii) 348,076 1,106,178 10,686,748
- 19. Unit Service Factor 61.2 30.5 63.4
- 20. Unit Availability Factor 61.2 30.5 63.4
- 21. Unit Capacity Factor iUsing MDC Net) 46.8 24.7 57.2
- 22. Unit Capacity Factor (Using DER Net) 45.4 23.9 55.5 0
3.9 12.9
- 23. Unit Forced Outage Rate
- 24. Shutdowns Scheduled Over Next 6 Months (Type. Date.and Duration of Each r None
- 25. If Shut Down At End Of Report Period. Estimated Date of Startup: N/A
- 26. Units In Test Status (Prior to Commercial Operation):
Forecast Achiesed INITIA L CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION 14/7 7)
}
6 ANN 4 4
) 'Nfd) l
,a w
,s DOCKETNO. 50-387 UNIT SHUTDOWNS AND POWER REDUCTIONS E
UNIT NAME One (D
M DATE July 3, 1985 o
COMPLETED BY L.A. Kuczimski Nic 6 REPORT MONT11 June. 1985 TELEPHONE (717)542-3759 I
"i
-c e
r>
3e
- n.,
Cause & Corrective cX Licensee E.t,
.2 E 5
g g"
No.
Date g
3g 4
,g5 Event u '2 6-Action to
$5 5
y= 6 y Report a viG Prevent Recurrence F
S 2
850209 S
276 C
4 NA NA NA Manual scram to cmmence first refueling outage. Breaker closed June 12, 1985 at 1200.
3 850612 S
3.4 B
9 NA NA NA Generator rmoved from grid for performance of turbine testing, i
2, 3
4 F: Forced Reason:
Method:
Exhibit G. Instructions S: Scheduled A Equipment Failure (Explain)
- 1. Manual for Preparation of Data -
B-Maintenance of Test 2-Manual Scram.
Entry Sheets for Licensee C Refueling 3-Automatic Scram.
Event Repos (LER) FileINUREG-D-Regulatory Restriction 4 Continuation 0161)
E-Operator Training & License Examination from previous month i
F-Administrative 5-Reduction 5
G-Operational Error (Explain)
Exhibit 1 - Same Source (9/77) llother (Explain) 9-Other
N,
'J 3
[..
p-UNIT I N STEAM ELECTRIC STATION Docket No.
50-387 Date July 3, 1985 Ccupleted By L.A. Kuczynski Telephone
-(717)S42-3759 Challanges to Main Steam Safety Relief Valves None L
Changes to the Offsite Dost Calculation Manual None 4
Major Changes to Radioactive Waste Treatment'Systens None a
r a
~-
o 4
AVERAGE DAILY UNIT POWER LEVEL
@% 3 z
E Cr) wg DOCKET NO.
50-388 L7 UNIT Two 0
3 DATE _ July 3,1985 ggg 3 COMPLE7ED BY L.A. Kuczynski TELEPHONE (717)542-3759 MONDI June, 1985 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)
(MWe-Net) 1 0
37 1029 2
0 gg 1035 3
98 39 1039 4
830 20 1044 5
893 21 1040 946 6
979 22 7
1028 753 23 g
1037 747 24 9
1026 25 757 10 1035 26 778 l
I 1043 27 1003 12 1041 1021
- g 1031 13 1049 29 14 1048 30 764 15 1047 33 16 1027 l
~
l INSTRUCTIONS On this format, list the average daily unit power level in MWe Net for each day in the reporting month. Compute to the nearest whole megawatt.
(9/771 l
l
y.~ w..
%.I y
3 W
LV-
- 23. J OPERATING DATA REPORT
@f DOCKET NO.
50-388 h
4 DATE July 3, 1985 NIC g COMPLETED BY L.A. Kugzynski TELEPHONE (7171542-3759 OPERATING STATUS Unit 2 N"
- 1. Unit Name:
Susaueh;mna Steam Nctrir genHnn June, 1985
- 2. Reporting Period:
- 3. Licensed Thermal Power (MWt):
3,293
- 4. Nameplate Rating (Gross MWe):
1,152 1.065
- 5. Design Electrical Rating (Net MWel:
1.069
- 6. Maximum Dependable Capacity (Gross MWe):
1,032
- 7. Maximum Dependable Capacity (Net MWe):
- 8. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report. Give Reasons:
None
- 9. Power Level To which Restricted. lf Any (Net MWel:
None
- 10. Reasons For Restrictions,11 Any:
None This Month Yr. to.Date Cumulatise i1. Hours In Reporting Period 720 3,335 3,335
- 12. Number Of Hours Reactor was Critical 664.7 3,041.6 3,041.6
- 13. Reactor Reserve Shutdown Hours 6.2 246.9 246.9
- 14. Hours Generator On-Line 651.4 2,968 2,968
- 15. Unit Reserve Shutdown Hours 0
0 0
- 16. Gross Thermal Energy Generated (MWH) 2.016.617 9,337.975 9.337.975
- 17. Gross Electrical Energy Generated (MWH) 649,852 3,052,832 3,052,832
- 18. Net Electrical Energy Generated (MWH) 627,349 2,945,269 2,945,269 90.5 89.0 89.0
- 19. Unit Service Factor
- 20. Unit Availability Factor 90.5 89.0 89.0 84.4 85.6 85.6
- 21. Unit Capacity Factor (Using MDC Net) 81.8 82.9 82.9
- 22. Unit Capacity Factor (Using DER Net) 9.5 11.0 11.0
- 23. Unit Forced Outage Rate
- 24. Shutdowns Scheduled Over Next 6 Months (Type. Date and Duration of Each 6:
None
- 25. If Shut Down At End Of Report Period. Estimated Date of Startup: July 7. 1985
- 26. Units In Test Status (Prior to Commercial Operation):
Forecast Achieved INITIA L CRITICALITY INITIA L ELECTRICITY COMMERCIA L OPERATION (u/77 )
1 gANN4 a 1 4!!N
\\
~
~
% b w)%"
s
'/
UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO. Sn-3RR UNIT NAME h M[
k PPal DATE July 3, 1985 D
COMPLETED BY L.A. Kuczynski e NIC SY REPORT MONT1( June, 1985 TELEPHONE (717)542-3759 w.
.E g
}
I Licensee Eg Cause & Corrective No.
Date h
3g
,s&
Event gy 3
Action to H
$5 j ;g g Report #
v1 O V
Prevent Recurrence g
8 10 850531 F
62.4 A
4 85-017-00 CB VALVEX Reactor recirculation pump
'A' dis-charge bypass valve developed a severe packing leak which led to the Unit shutdown. The valve was re-paired and the Unit returned to ser-vice on June 3, 1985.
Note: Power reduction conmenced on May 30, 1985.
11 850630 F
6.2 A
3 85-021-00 EG TlWISF Main generator neutral overvoltage was caused by the failure of a main transforner 'C' phase low voltage bushing. The bushing was reolaced and the Unit was returned to service on July 7, 1985.
I 2
3 4
F: Forced Reason:
Method:
Exhibit G-Instructions S: Scheduled A Equipment Failure (Explain) l-Manual for Preparation of Data B-Maintenance of Test 2 Manual Scram.
Entry Sheets for Licensee C Refueling 3 Automatic Scram.
Event Report (LER) File (NUREG-D-Regulatory Restriction 4 Continuation 0161)
E-Operator Training & License Examination from previous month F-Administrative 5-Reduction 5
G-Operational Error (Explain)
Exhibit 1 - Same Source (9/77)
Il-Other (Explain) 9-0ther
i 3.(-.
UNIT II SUSQUEHANNA STEAM ELECI'RIC STATION Docket No.
50-388 Date July 3, 1985 Ccmpleted By L.A. Kuczynski Telephone (717)542-3759 Challenges to Main Steam Safety Relief Valves Follcwing the scram of June 30, 1985, SRV's 'B' and 'E' actuated autcnatically. They reseated properly.
RX PRESSURE. (psig)
RX PRESSURE (psig)
OPEN CIDSED AT SRV OPEN AT SRV CIOSE 17:46:56 (B) 17:47:07(B) 1077 976
- 17:46:56 (E) 17:47:07(E) 1077 976 Changes to the Offsite Dose Calculation Manual None Major Changes to Radioactive Waste Treatment Systems None-4 s
L1
m V.
t ppg Pennsylvania Power & Light Company Two North Ninth Street
- Allentown, PA 18101 + 215 / 770-5151 Harold W. Keiser Vice President-Nuclear Operations 215/770-7502 JUL 151985 Director, Data Automation &
Management Information Division Attention:
Mr. M. R. Beebe Management Information Branch Office of Resource Management U.S. Nuclear Regulatory Commission Washington, D.C.
20555 SUSQUEHANNA STEAM ELECTRIC STATION MONTHLY OPERATING REPORTS ER 100450 FILE 841 Docket Nos. 50-387/NPF-14 PLA-2500 50-388/NPF-22
Dear Mr. Beebe:
The June 1985 monthly operating reports for Susquehanna SES Units 1 and 2 are attached.
Very truly yours, H. W. Keiser Vice President-Nuclear Operations Attachment cc:
Dr. Thomas E. Murley Regional Administrator-Region I U.S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, PA 19406 Director Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, D.C.
20555 Attn: Document Control Desk (12 copies)
Mr. R. H. Jacobs - NRC Ms. M. J. Campagnone - NRC N'4